Thank you for purchasing this product.
This product complies with the statutory national and European requirements.
To maintain this status and to ensure safe operation, you as the user must observe these operating instructions!
These operating instructions are part of this product. They contain important notes on
commissioning and handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating instructions for reference!
If there are any technical questions, please contact: www.conrad.com/contact
The symbol with the lightning in the triangle is used if there is a risk to your health, e.g.
due to an electric shock.
The symbol with the exclamation mark in the triangle is used to indicate important
information in these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on operation.
Dear customer,

This thermal imaging camera has a temperature measuring range of -20 °C to +600 °C and sensitivity of 254 mK. The 32 x 32-pixel infrared sensor measures temperatures at a frequency of
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read the instructions carefully and store them in a safe place. Make this prod- uct available to third parties only together with its operating instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.
Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/ guarantee.
- is visibly damaged,
- is no longer working properly,

- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.


1 LCD display screen
8 Visible light sensor
11 Micro USB interface


1 Long press the Back/Power button for 3 seconds to display the start-up screen. After start- up, the thermal image will be displayed on the screen.
2 Target an area or object with the thermal imaged points and check the thermal image. The relative temperature is shown from hot to cold through the color table (corresponding to light to dark). The infrared temperature reading (shown above the thermal image) indicates the temperature of the target measuring point aimed at the cross cursor on the display screen.

3 Press the Up and Down button to adjust the infrared and visible light fusion ratio.
4 Press the Trigger button to take a thermal image, which will be displayed surrounded by white boxes.
5 Press the OK button to save the captured thermal image. The thermal image is stored in the internal storage and can be viewed by connecting the imager to a computer using the USB cable. Press the Back button to continue to scan the target area or object.
6 While scanning an area or object, press the OK button to enter the menu options, where various settings and information can be accessed. Press the Back/Power button to exit the menu.
Long press to turn the camera on/off. Short press to exit menu options or delete saved images.
Short press to enter menu options, confirm settings or confirm image save/delete (in Preview mode).
- Short press to scroll through settings in the setup menu, scroll through saved images in
Preview mode or alter the visible-infrared blend in capture mode.
- Long press to continuously add/subtract values for settings such as emissivity.
Press to capture an image and press again to preview an image.

In Capture mode, press the Confirm/Menu OK button to enter the settings menu. Use the Up/Down and Confirm/Menu OK buttons to navigate the menu.



Go to the EMS menu and press the Up/Down buttons to adjust the value. Note that long pressing the Up/Down buttons will continuously adjust the value. Press the Confirm/Menu OK button to confirm any changes or Back/Power to exit.


Go to the Unit menu and press the Up/Down buttons to change the units. Press the Confirm/ Menu OK button to confirm any changes or Back/Power to exit.

Go to the Max./Min. Temp menu and press the Up/Down buttons to change the settings. Press the Confirm/Menu OK button to confirm any changes or Back/Power to exit.


Go to the Color Table menu and press the Up/Down buttons to change the color table. Press the Confirm/Menu OK button to confirm any changes or Back/Power to exit.

Go to the Date Time menu and press the Up/Down buttons to change the date and time. Press the Confirm/Menu OK button to move to the next item and then confirm any changes, or Back/Power to exit.


Go to the Preview menu, select the image and press the Confirm/Menu OK button to open the image. Press the Up/Down buttons to move the blue highlight bar, and press Confirm/ Menu OK to confirm changes to the stored temperature measurement.

With the image open in the Preview menu, press the Confirm/Menu OK button and press the Confirm/Menu OK button again to confirm deletion, or Back/Power to exit.


Go to the Alarm menu, select either High Alarm or Low Alarm and press the Confirm/Menu OK button to confirm, or press the Back/Power button to exit. If the High Alarm is selected, press the Up/Down buttons to adjust the high temperature alarm threshold. Then press the Confirm/Menu OK button to turn the alarm on/off, or the Back/Power button to exit.

If the Low Alarm is selected, press the Up/Down buttons to adjust the low temperature alarm threshold. Then press the Confirm/Menu OK button to turn the alarm on/off, or the Back/ Power button to exit.


Go to the Backlight Adjust menu and press the Up/Down buttons to adjust the backlight. Press the Confirm/Menu OK button to confirm any changes, or Back/Power to exit.

Aligning visible images with infrared images makes results easier to understand. Go to the Fusion Distance menu and press the Up/Down buttons to adjust the distance. Press the Confirm/Menu OK button to confirm any changes, or Back/Power to exit.


Go to the Language menu and press the Up/Down buttons to change the language. Press the Confirm/Menu OK button to confirm any changes, or Back/Power to exit.

Go to the Information menu to view the factory information, version number and other cam- era details. Press the Back/Power to exit.

Pitch 0.90-0.98
Concrete 0.94
Cement 0.96
Sand 0.9
Soil 0.92-0.96
Water 0.92-0.96
Ice 0.96-0.98
Snow 0.83
Glass 0.90-0.95
Ceramics 0.90-0.94
Marble 0.94
Plaster 0.80-0.90
Stucco 0.89-0.91
Brick 0.93-0.96
Cloth (black) 0.98
Human skin 0.98
Soap Bubble 0.75-0.80
Charcoal (powder) 0.96
Lacquerware 0.80-0.95
Lacquerware (matte) 0.97
Rubber (black) 0.94
Plastic 0.85-0.95
Substance Emissivity

Wood 0.9
Paper 0.70-0.94
Chromium oxide 0.81
Copper oxide 0.78
Iron oxide 0.78-0.82
Textile 0.9
Do not use any aggressive cleaning agents, rubbing alcohol, or other chemical solu-
tions as they can cause damage to the housing and functioning of the product.
Electronic devices are recyclable waste and must not be disposed of in the household
waste. At the end of its service life, dispose of the product in accordance with applica- ble regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.
You as the end user are required by law (Battery Ordinance) to return all used (re-
chargeable) batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labeled with this symbol to indicate that disposal in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) bat- teries, e.g. below the trash icon on the left).

Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfill your statutory obligations and contribute to the protection of the environment.
Power supply 3 x AAA battery (included)
Measuring range -20 °C to +600 °C
Sensor type 32 x 32-pixel infrared sensor
Image capture frequency
Thermal sensitivity (NETD) ≤254 mK
Infrared band 8-14 µm
Field of view 33° x 33°
Color table Iron Red, Color RGB, Grayscale (White Heat),
Emissivity 0.01-1.00 (adjustable)
Visible and infrared fusion distance 0.5 m, 1.0 m, 2.0 m
Fusion view options 50% step
Recommended measuring distance 30 cm
Internal memory capacity over 100 images
Display type 5.08 cm (2.0-inch) 240 x 320 TFT LCD
Casing rating IP54
Temperature accuracy ±2 % ±2 °C (tested at 25 °C)
Operating/storage conditions 0 °C to +50 °C (operating)
-20 °C to +60 °C (storage) 10-90 % relative humidity (non-condensing)
Dimensions (L x W x H) 58 x 84 x 175 mm
Weight 212 g (without batteries)
Grayscale (Black Heat)