Read the complete user manual before carrying out the installation and activating the system
The motion detector uses Passive Infrared Technology (PIR) and is suitable for outdoor use. Lighting control through motion detection is useful for driveways, gardens, houses, holiday homes, car parks and public places.
The outdoor motion detector is available in two versions: White (350-20058) and Anthracite (350-20158).
2.1. Positioning
The outdoor motion detector reacts to motion and heat in its environment. It is most sensitive to diagonal movement (walking direction) with respect to the detection beams (fig. 1).
Installation tips: - The recommended mounting height is 2 to 3 m. At a height of 2.5 m, the White outdoor motion detector has a maximum
detection range of 14 m at a detection angle of 180°. Note: The maximum detection range of the Anthracite outdoor motion detector is 11 m. - Do not install the outdoor motion detector near moving objects (such as tree branches and leaves), heat sources or air
currents. This can result in undesired activation of the outdoor motion detector. - Do not position the outdoor motion detector towards the light source it is meant to activate.
2.2. Mounting
Opening the outdoor motion detector (fig. 2)
A. Insert a screwdriver into the opening at the bottom of the outdoor motion detector. Open the locks on the cover using a
screwdriver. B. Click the cover off.
Mounting (fig. 2) and connecting the outdoor motion detector
C. Ensure the arrows on the sensor portion and the outdoor motion detector housing are pointing in opposite directions. D. Pull on the top of the sensor portion. E. Release the clamp on the bottom. F. Remove the sensor portion. G. Guide the cable through the openings in the bottom of the housing and attach the unit to the wall. Connect the sensor
(fig. 3.1). Connect a push button if manual operation of the outdoor motion detector is also desired (fig. 3.2). H. Mount the assembly by placing the sensor portion back onto the bottom of the housing. Pay attention to the direction of
the arrows. I. Hook the cover over the top and click it onto the sensor portion.

3. OPERATION AND SETTINGS
3.1. Operation
3.1.1. General The outdoor motion detector is ready to use three to five minutes after connecting to the mains voltage (warm-up time). The connected lighting will be switched off as soon as the device is ready to use.
3.1.2. Automatic ON The integrated light sensor continuously measures the light level in the detection zone and compares this level with the preset value specified using the LUX key. The light sensor automatically switches the lighting on only when the detector detects motion within the detection range and when the daylight level drops below the preset lux value. The lighting remains on as long as motion is detected.
3.1.3. Automatic OFF The lighting automatically switches off when the preset daylight level is reached. The integrated timer is used to set the switch-off delay as desired. The lighting will remain on for the specified delay time after the last motion is detected. Once the switch-off delay has expired, the lighting will switch off.
3.1.4. Manual ON The lighting can also be manually switched on by pressing the 230 Vac NC push button. Press and hold the push button for more than four seconds to switch the lighting on, regardless of the measured daylight level.
3.2. Settings At delivery, the light sensitivity, switch-off delay and detection range are set as follows (factory settings):
light sensitivity ± 35 lux switch-off delay ± 7 min detection range Anthracite: 11 m White: 14 m
These values can be adjusted using the potentiometers under the cover as follows (fig. 4):
light sensitivity 5 lux to infinite (regardless of daylight level) switch-off delay 8 s to 30 min detection range Anthracite: 6, 8 or 11 m
To adjust the settings for the light sensitivity and switch-off delay, open the cover and turn the potentiometers to the desired position using a screwdriver. To change the detection range, move the adjustable sensor portion up or down.
If a section of the detection area is to be excluded from detecting any motion, cover the sensor lens using the cover cap supplied. You can cut the cover cap to size according to the desired range. Figure 5 shows the range corresponding to a cap customised for a range set to 14 m. Follow the instructions in figure 6 to slide the cap into the slot.

4. MAINTENANCE
Dirt may prevent the outdoor motion detector from functioning properly. Therefore, always keep the lens clean and dry. Use a damp cloth and water with some detergent to clean the lens. Never exert pressure to wipe the lens clean. The outdoor motion detector should be replaced if the lens or other parts of the outdoor motion detector are defective.
The outdoor motion detector is not activated.
The outdoor motion detector is connected incorrectly.
Connect the outdoor motion detector as described.
No/little detection during the walking test.
The outdoor motion detector is positioned incorrectly.
Install the outdoor motion detector as described.
The lens is covered, dirty or defective. - Remove the cover and/or clean the
lens. - If the lens is defective, the sensor
should be replaced.
Dimensions: 125 x 72 x 63 mm (HxWxD) Power supply voltage: 230 Vac ± 10% Power consumption: 0.6 W Relay contact: NO (max. 10 A), light- and motion-sensitive Maximum load: incandescent lamps (2300 W) 230 V halogen lamps (2300 W) all low-voltage halogen lamps (2300 VA) fluorescent lamps (non-compensated) (1200 VA) economy lamps (CFLi) (1200 VA) Maximum switching capacity: 140 uF Maximum inrush current: 80 A/20 ms Detection angle: 180° Mounting height: 2 – 3 m Detection range (at a height of 2.5 m): semicircular, up to max. 11 m (350-20158) semicircular, up to max. 14 m (350-20058) Light sensitivity: 5 lux – infinite Switch-off delay: 8 s – 30 min Protection degree: IP54 Protection class: class II devices Ambient temperature: -20 – 45°C Cabling: 3 x 1.5 mm² Cable inlet: 2 x 12.5 mm Quality mark: CE marked in compliance with EN 60669-2-1
Problem Cause Solution

7. WARNINGS REGARDING INSTALLATION
- The installation should be carried out by a registered installer and in compliance with the statutory regulations. - This user manual should be presented to the user. It should be included in the electrical installation file, and it should be
passed on to any new owners. Additional copies are available on the Niko website or via the Niko support service. - During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations. - the technology currently available at the time of installation. - this user manual, which only states general regulations and should therefore be read within the scope of each specific
installation. - the rules of proper workmanship.
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can be found at www.niko.eu under the “Help and advice” section.
- The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of purchase of the
product by the consumer. If there is no invoice, the date of production applies. - The consumer is obliged to inform Niko in writing about the non-conformity, within two months after stating the defect. - In case of a non-conformity, the consumer only has the right to a product repair or replacement free of charge, which shall
be decided by Niko. - Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or careless use, incorrect
operation, transformation of the product, maintenance that does not adhere to the maintenance instructions or an external cause, such as damage due to moisture or overvoltage. - The compulsory regulations of the national legislation concerning the sale of consumer goods and the protection of the
consumer in the countries where Niko sells, directly or via sister companies, subsidiaries, chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned rules and regulations.

180°



minder gevoelig moins sensible weniger empfindlich less sensitive
gevoeliger plus sensible empfindlicher more sensitive









L'
N
L L'
N
N
Fig./Abb. 3.1 Fig./Abb. 3.2






sa Niko nv Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — www.niko.eu
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| The outdoor motion detector is not activated. | The outdoor motion detector is connected incorrectly. | Connect the outdoor motion detector as described. | p.3 |
| No/little detection during the walking test. | The outdoor motion detector is positioned incorrectly. | Install the outdoor motion detector as described. | p.3 |
| No/little detection during the walking test. | The lens is covered, dirty or defective. | - Remove the cover and/or clean the lens. - If the lens is defective, the sensor should be replaced. | p.3 |