Read the complete manual before attempting installation and activating the system.
- Power up time (stabilization time). The lighting on channel 2 and the integrated indicator LED are switched on for 4min after which the lighting in channel 1 is switched on. Both channels are switched off after 7min. - Connect ground to terminal . The 350-20053 can switch a load of 2300W (incandescent lamps) per channel. See also ‘7. TECHNICAL DATA’.
2. MOUNTING 2.1. Installation (fig.1) A The ideal amount of daylight is obtained by positioning the 350-20053 with its light opening facing incident daylight. B If the 350-20053 is mounted directly on the ceiling, the opening distance of 105mm can be used. Please note that the cable inlet is turned 45° in relation to the fixing holes. C If the 350-20053 is fitted to a flush mounting box, the holes provided for this purpose are used, and the base cap is punched out. Insert the cable correctly in accordance with the instructions for a fixed installation. Please note that all installation work must take place with the mains voltage disconnected. - Do not expose the presence detector to direct sunlight, air flows of air
2.4. Parallel switching Mounting 2 sensors on the same contact affects the light control system through the lux function and is advized against.
3. OPERATION AND USE 3.1. General operation The integrated light sensor continuously measures the light level in the zone and compares it with the preset value specified via the lux button (fig.7). The lighting is switched on if the light level drops below the preset value and the movement sensor detects activity in the detection zone. The integrated ‘delayed off’ function (1-30min.) ensures that the lighting remains on until the sensor does not detect activity anymore or the selected light level is reached. Set the ‘delayed off’ time with the TIME button (fig.7).
conditioning systems, heating... - Please make sure the lens is kept clean and dry. You can clean it with
3.2. Classroom function (fig.8) Fig. 8 shows how the sensor has to be positioned and how the classification of channel 1 and 2 has to be set for an optimum use of the sensor. a) The 350-20053 PIR sensor 360° switches on the lighting if the manual
a slightly damp cloth.
2.2. Mounting the sensor (fig. 2) - Press the sensor into the terminal strip in the base and fit the safety screw Pozidriv (PZ) 0 / Philips (PH) 1. - Set the 350-20053 as described in ‘4. SETTINGS’. - The detection zone can be limited (fig. 6). - Mount the sensor’s cover.
switch is pressed. - The channel 2 lighting is switched on. - The channel 1 lighting is switched on if the light level is lower than the
preset value and the movement sensor registers activity in the coverage area. If there is no activity in the coverage area and the cut-out delay of 1-30min has expired, the lighting in channel 1 and subsequently channel 2 is switched off. The sensor is then blocked. For switching the light on again, press the manual switch. b) The lighting can be switched off/on manually, e.g. to show a film or
2.3. Connection (fig.3 and 4) - Switch off all power. - Power from the mains is supplied via the terminals labelled L and N. - Channel 1: The charge is connected via the terminals labelled 1, N. - Channel 2: The charge is connected via the terminals labelled 2, N. - The manual switch can be connected between the terminals labelled L1 ( ).
video.

3.3. 2-channel lighting The use of 2-channel lighting provides optimal control and significant energy saving. Channel 1: If the sensor is activated manually, the lighting is switched on/off automatically, depending on the preset lux value, in relation to the measured light level and movement. Channel 2: The lighting is switched on and off manually. Channel 2 is also switched off when the cut-out delay expires.
4.2. PIR TEST mode: testing the PIR function Switch on the contacts DIP1 and DIP2. Due to the PIR activation, the lighting is switched on for 5s. The integrated indicator (LED) indicates that the PIR is activated. Attention: During this test, the daylight blocking is disabled. Finish by switching off the contacts DIP1 and DIP2.
4.3. LED indication ON: indication of PIR activation Switch on the contact DIP1. You are recommended to switch off this contact if you do not wish to indicate ‘supervision’.
3.4. Detection zone The detector 350-20053 is designed for mounting on a ceiling. When mounted on a height of 2.5m, the sensor detects activity over a diameter of 20m and motion within a zone of 360°. The detector has a lens area with a diameter of 5m and over 618 fields that guarantees an optimum detection of the slightest motions. Mount the 350-20053 on the ceiling at a height of 2.5m to 3.0m. Position it above the desk, at approx. 1m away from the seat. The sensor has an optics with 2 detection zones: one for small distances (A + B) to detect small motions and one for larger distances (C + D) to detect body motions. This combination guarantees excellent lighting control and optimum energy saving (fig. 5). If the detection zone is too large, you can limit it by mounting the supplied cover. This enables the max. reach of Ø20m to be reduced to Ø12m, Ø5m or Ø3m. The angle of 360° can be reduced in steps of 45° (fig.6).
4.4. PIR sensitivity setting Contacts DIP3 and DIP4 enable you to set the sensor’s sensitivity.
5.2. The lighting does not switch off - Check whether the value of the TIME button is not too high. - Leave the detection field, so the sensor cannot be activated. - Check whether the voltage is constant. - Make sure the sensor is not pointing at an object that can cause temperature fluctuations, such as air conditioning, a heating installation...
4.1. Lux TEST mode: measuring the level of daylight Switch on the contacts DIP1 and DIP2. In this position, the lighting is switched off. Slowly turn the lux button from min. to max. until the integrated indicator (LED) is switched on. At this point, the lux setting is identical to the daylight level measured by the sensor. If the lux button is turned to the min. value, the lighting is switched off at a lower level of daylight. If the lux button is turned to the max. value, the lighting is switched off at a higher level of daylight. Finish by switching off the contacts DIP1 and DIP2.
5.3. After setting the lux value, the detector continues to switch, regardless of the setting. Turn off the mains during min. 5s. and switch it on again.

- In case of questions, you can consult Niko’s support service or contact
a registered control organisation. Support Belgium: Support UK: +32 3 778 90 80 +44 1525877707 website : http://www.niko.be http://www.nikouk.com e-mail: [email protected] sales@nikouk.com In case of a defect, you can return your product to a registered Niko wholesaler, together with a clear description of your complaint (Conditions of use, stated defect…).
7. TECHNICAL DATA Supply voltage 230V ac ±10% 50Hz Switch for channels 1 and 2 μ 10A 250V AC, N.O. Connection current 80A/20ms Load R 2300W (filament lamp) L 1200VA (fluorescent tube) C max. 140μF Lux range 10...1000lx Hysteresis +10% Cut-out delay 1-30min Sensitivity selected manually Manual on/off via power switch Activation indicator on/off selected manually Test modes selected manually Inherent consumption approx. 1.5W Protection class IP20 Ambient temperature -5°C...+50°C Cable entry duct 2 x Ø12mm Installation height max. 3m EMC + LVD compliant in accordance with EN 60669-2-1
the invoice date of purchase of the product by the consumer. If there is no invoice, the date of production applies. - The consumer is obliged to inform Niko in writing about the defect, within
two months after stating the defect. - In case of a failure to conform, the consumer has the right to a repair or
replacement (decided by Niko) free of charge. - Niko cannot be held liable for a defect or damage as a result of an incorrect
installation, improper or careless use or wrong usage or transformation of the goods. - The compulsory regulations of the national legislation concerning the
sales of consumer goods and the protection of the consumers in the countries where Niko sells, directly or via sister or daughter companies, chain stores, distributors, agents or permanent sales representatives, take priority over the rules and regulations mentioned above.
with the statutory regulations. - This user manual has to be handed over to the user. It has to be included in the
electrical installation file and has to be passed on to any new owners. Additional copies are available on the Niko website or via the support service. - During installation, the following has to be taken into account (not limited
to list below): - The statutory laws, standards and regulations; - The state of the art technique at the moment of installation; - This user manual, which must be read within the scope of each specific
installation, only states general regulations; - The rules of proper workmanship


L 1 N L 1 L 2 1 2
/ 0 ) Z P ( vir d iz o P
1 2 L 1 N L 1 L 2
L :et o N 1 e s a h p e m a s &


m 0 5 2 5 , 3 1 ø


s g nitt e s y r o t c a F
s g nitt e s y r o t c a F F F O
e d o m t s e T - X U L ) A
e d o m t s e T - R I P ) B
ytivitis n e s . ni M ) D
ytivitis n e s w o L ) D
ytivitis n e s h g i H ) D
ytivitis n e s .x a M ) D


nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel.: + 32 3 778 90 00 — fax: + 32 3 777 71 20
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.