
Read the complete manual before carrying out the installation and activating the system.
Function keys and LEDs
Begin and end a call by pressing briefly.
Switches off the ring tone. The red LED lights up.
Displays the camera image and pages through the available camera images.
Transmit control function 8 to operate relay 10-831.
Call up the menu.
Cabling The internal video unit 10-570 requires 6-wire cabling with a twisted cable for optimal image quality. The diameter of the wires determines the maximum distance allowable between the power supply and the internal video unit.


Installation diagram:

14 15 16 17 18 19 20 21 22 23 24 25
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17



OFF: The device is not the last monitor on the cable.


a b E P M C V1 V2
To add the device to an installation as the 3rd or 4th device on a bell push button, program it in parallel (as SLAVE) with another internal unit (see below, 4.2.3). To do this, you need the serial numbers of the other devices. The serial numbers of the internal and external units can be found on the device and can be affixed to the installation diagram for easy programming. It is also possible to look up the serial number in the menu (see 4.2.5, Device info.).
Example of a serial number Changing menu functions and settings

Press and use the instructions at the bottom of the screen to scroll through the menu or to change the settings.
1 Internal Call . 2 Control and Light 3 Automatic Function 4 Intercom Setting

If it is not possible to make an internal call, you receive the message “NO PRESET INTERNAL CALL”.
To set the calls, see the “INSTALLER SETTINGS” menu.

If internal calls are activated, then follow the instructions at the bottom of the screen to select another internal unit and make a call.

You can operate various contacts via this menu. When the contact is selected, the device transmits a specific control function. These control functions can be taught to a programmable relay (10-830, 10-836 or 10-837).
1 Contact 1 . 2 Contact 2 3 Contact 3 4 Licht Contact
“Contact 1” = control function 8 + serial number of the device. “Contact 2” = control function 9 + serial number of the device. “Contact 3” = control function 10 + serial number of the device. “Light Contact” switches the light circuit relay in the power supply.
You can operate relay 10-831, without programming, by using “Contact 1”.
Floor Door: After a floor call, the local door lock can be operated with a programmable relay 10-83x using control function 11 (CF 11). If is pressed within 30 seconds after a floor call, this control function is transmitted.
Call Divert: If this function is active, the call will be diverted to another internal unit.
Doormatic: If this function is active, the door will automatically open when there is a call (ring- and-come-in function). This option can be used in home practices of offices with free access. The green LED lights up if this function is activated.
At the time of delivery, only the “Doormatic” function is available. You, as the installer, can make the other functions available to the user. See section 4.2.3: “Changing the installation parameters”.
Both the user and the installer can change certain settings. However, the installer’s settings menu is secured so that the technical settings cannot be changed by the user.
1 User . 2 Installer
The beep sound that occurs when the keys on the internal unit are touched can be switched on or off here. Both the ring volume and the image settings can be changed.
Control and Light · Automat Functions · User

4.2:Changing the settings for the installer Installer
1 Ringtone . 2 AS Adress 3 Parameter 4 Internal Call 5 System 6 DeviceInfo
Intercom Ringtone As1 Tone: Alpha1 As2 Tone: Alpha2 As3 Tone: Alpha2 As4 Tone: Alpha2 As5 Tone: Alpha2 As6 Tone: Alpha2 As7 Tone: Alpha2 As8 Tone: Alpha2 Internalcall: Gong FloorCall: Alpha3
Use the instruction at the bottom of the screen to change the ring tones of the different types of calls.
The addresses of the different external units (AS1-8) can be changed using “Intercom AS”.
Use the instructions at the bottom of the screen to set the addresses of the external units. A specific ring tone can be set for the external units which have an address assigned to them.
AS1: 0 AS2: Empty AS3: Empty AS4: Empty AS5: Empty AS6: Empty AS7: Empty AS8: Empty
Select an address -0 to 31 for an external video unit -32 to 63 for an external audio unit
If the call originates from an internal audio unit, the screen will not light up.
Display Time: The screen darkens after a set time. This time can be set between 20s and 119s. At 120s, the screen stays on continuously.
Display Time: 60 Speech Time: 45 Parallel SN: 000000 Video Floor: Disable Floor Door Open: Allowed Call Divert: Allowed Call Divert SN: 000000 Doormatic: Allowed
Speech Time: The speech connection is interrupted after a set time. This time can be set between 20s and 119s. At 120s, the conversation will continue until it is dis connected by the user.
Parallel SN: The device can function in parallel (as slave) with another internal unit (the master). Enter the serial of the internal unit (master) with which the device must ring.
Video Floor: On the M and C terminals of each internal unit, a camera (standard CVBS) can be connected which displays the image of the apartment door. If you ac tivate this option, this image will always be displayed first when someone rings at the floor bell push button or if the screen is activated using .
Floor Door: After a floor call, the local door lock can be operated with a programmable relay 10-83x using control function 11. If is pressed within 30 seconds after a floor call, this control function is transmitted. If you make this function available to the user, then this function can be switched on or off in the automatic functions menu (see section 3: “Setting automatic functions”).
Call Divert: If this function is active, the call will be diverted to another internal unit. If you make this function available to the user, then this function can be switched on or off in the automatic functions menu (see section 3: “Setting automatic functions”).
Call Divert SN: Enter the serial number of the internal unit to which a call must be diverted here.
Doormatic: If this function is active, the door will automatically open when there is a call (ring-and-come-in function). The green LED lights up if this function is activated. If you make this function available to the user, then this function can be switched on or off in the automatic functions menu (see section 3: “Setting automatic functions”).
Intercom Parameter

Internal Call 01: Living SN 828725 02: Bisness SN 824065 03: Reception SN 213695 04: Room 001 SN 412690 05: Room 0 SN 0 06: Room 0 SN 0 07: Room 0 SN 0 08: Room 0 SN 0 09: Room 0 SN 0 10: Room 0 SN 0
Here you can assign names to and identify the internal units that can be called by the user. You can choose from 10 different name designations or assign a number to each internal call. The possible name designations are: Kitchen, Living room, Bedroom, Upstairs, Business, Private, Reception, Concierge, Doctor, Emergency.
By pressing you can move the cursor to the next changeable field. Using or choose the correct name designation or number of the internal unit that can be called and then enter the serial number of the internal unit in the same manner. Only the internal calls that you have programmed will be visible to the user.
OSD Info: If “Disabled”, the extra information (such as external unit number and key functions) which accompanies a call is no longer displayed on the screen.
Language: 5 languages can be set: English (standard), Dutch, French, German and Slovak.
VOL.: The volume of the micro and the speaker can be adjusted.
Factory Setting: All settings are erased and the device returns to the factory de faults.
RESET: The device is restarted and calibrates itself.
Here you can find serial number (SN), the article number and the software version.
ID: 194 Name:10-570 Ver: 5.A.6 SN: 481296 BBS: 1.2.0 Mode:Freehand Alarm:No PS: No Touch:Yes CUS: NIKO
Setting times By default, the following times are programmed:
Speech time after initiating a call (SPEECH TIME) 45s Automatic conversation cut-off time after the door is opened 4s Time that the camera image or the menu remains active (DISPLAY TIME) 60s Number of times that the green LED flashes when the video or speech channel is busy 3 times within 6s Time that a call from an external unit or a floor bell push button is signalled 120s Time that a floor call is remembered 30s
System Parameter · Device Info · Back

A list of other possible problems with their causes and solutions is given below.
Problem Cause Remedy You hear a negative tone when pressing .
Programming error. Erase the programming and programme again. System is still in programming mode. Exit programming mode. You press , but nothing happens.
Video internal unit is not connected correctly. Check the wiring.
Two functions assigned to the button. If a call is in progress, the relay switches to open the door. If no call is in progress, the light relay switches. The image on the video internal unit is not clear.
Replace the current cable with a suitable cable.
The gain on the splitters is not set correctly. Adjust the gain on the splitters with the potentiometers. No image on the video internal unit. The other functions work OK.
Check the wiring (see wiring diagram).
The terminal resistor is not correctly configured. Set the terminal resistor correctly
Additional copies are available on the Niko website or via the Niko support service. - During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations. - the technology currently available at the time of installation. - this user manual, which only states general regulations and should therefore be read within the scope of each specific installation. - the rules of proper workmanship.
is no invoice, the date of production applies. - The consumer is obliged to inform Niko in writing about the non-conformity, within two months after stating the defect. - In case of a non-conformity, the consumer only has the right to a product repair or replacement free of charge, which shall be decided by Niko. - Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or careless use, incorrect operation, transformation of
the product, maintenance that does not adhere to the maintenance instructions or an external cause, such as damage due to moisture or overvoltage. - The compulsory regulations of the national legislation concerning the sale of consumer goods and the protection of the consumer in the countries where
Niko sells, directly or via sister companies, subsidiaries, chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned rules and regulations.
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| You hear a negative tone when pressing . | Programming error. | Erase the programming and programme again. | p.8 |
| You hear a negative tone when pressing . | System is still in programming mode. | Exit programming mode. | p.8 |
| You press , but nothing happens. | Video internal unit is not connected correctly. | Check the wiring. | p.8 |
| You press , but nothing happens. | Two functions assigned to the button. | If a call is in progress, the relay switches to open the door. If no call is in progress, the light relay switches. | p.8 |
| The image on the video internal unit is not clear. | Conductors V1 and V2 have been reversed. | Reverse conductors V1 and V2. | p.8 |
| The image on the video internal unit is not clear. | Cable is unsuitable: • cable distance is too great; • cable is eroded; • cable cross-section too small; • cable is not a twisted pair cable. | Replace the current cable with a suitable cable. | p.8 |
| The image on the video internal unit is not clear. | The gain on the splitters is not set correctly. | Adjust the gain on the splitters with the potentiometers. | p.8 |
| No image on the video internal unit. The other functions work OK. | Wiring is not connected correctly: • M or P missing; • V1 or V2 not connected. | Check the wiring (see wiring diagram). | p.8 |
| No image on the video internal unit. The other functions work OK. | The terminal resistor is not correctly configured. | Set the terminal resistor correctly | p.8 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.