Before using the appliance, always read the operating instructions and keep them readily available.
Purpose and intended use
Besides the operating instructions and the binding accident prevention regulations valid in the country of use, observe recognised regulations for safety and proper use.
– – only be used by persons, who have been instructed in its correct usage and explicitly commis- sioned with the task of operating it – – only be operated under supervision
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
Children should be supervised to ensure that they do not play with the appliance.
The vacuum cleaners described in this operating manual are suitable for
– – sucking up dust and liquids – – dust suction for handheld power tools – – commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices and rental businesses – – separation of dust with an exposure limit of greater than 1 mg/m³ (dust class L). Please observe regulations valid in your country.
– – hot materials (burning cigarettes, hot ash, etc.) – – flammable, explosive, aggressive liquids (e.g. petrol, solvents, acids, alkalis, etc.) – – flammable, explosive dust (e.g. magnesium dust, etc.)
– – only be used indoors and not outdoors – – be protected against UV radiation
Before starting work, the operating staff must be informed on
– – use of the vacuum cleaner – – risks associated with the material to be picked up – – safe disposal of the picked up material
When dust removers are used, the rate at which air is exchanged in the room must be adequate if the exhaust air from the vacuum cleaner is blown into the room (please observe regulations valid in your country).
Only use the appliance if it is in undamaged condition. Never use the vacuum cleaner without a filter, or if the filter is damaged.
Ensure that the voltage shown on the rating plate corresponds to the voltage of the local mains power supply. It is recommended that the vacuum cleaner should be connected via a residual current circuit breaker.
Inspect power cord regularly to detect signs of damage, e.g. cracks or ageing. If the power cord is damaged, it must be replaced by Makita-Service or an electrician to avoid danger before use of the vacuum cleaner is continued. Use only the type of power cord specified in the operating manual.
As an extension lead, only use the version specified by the manufacturer or one of a higher quality.
Before start-up

When using an extension lead, check the minimum cross-sections of the cable:
Cable length Cross section < 16 A < 25 A up to 20 m 1,5 mm2 2,5 mm2
20 to 50 m 2,5 mm2 4,0 mm2
Switch position Function I On 0 Off AUTO Auto-On/Off
Before liquids are picked up, always remove the filter bag.
Cleaning the filter element
If suction performance drops: 1. Switching on the vacuum cleaner. 2. Close the nozzles or suction hose opening with the palm of your hand. 3. Press the button to start filter cleaning for at least three times for two seconds each. The resulting stream of air removes attached dust from the slats of the filter elements. 4. If the suction power is too low after filter cleaning: replace filter.
E Connecting electrical appliances
Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only.
Before plugging an appliance into the appliance socket: 1. Switch off the vacuum cleaner. 2. Switch off the appliance to be connected.
F + G Maintenance, cleaning and repair
Only carry out maintenance work described in the operating instructions. Always pull out the mains plug before cleaning and maintenance of the vacuum cleaner. Never spray water on to the upper sec- tion of the vacuum cleaner: Danger for persons, risk or short-circuiting.
The use of non-genuine spare parts and accessories can impair the safety of the appliance. Only use spare parts and accessories from Makita.
During maintenance and cleaning, handle the vacuum cleaner in such a manner that there is no dan- ger for maintenance staff or other persons.
In the maintenance area
– – use filtered compulsory ventilation – – wear protective clothing – – clean the maintenance are so that no harmful substances get into the surroundings
During maintenance and repair work all contaminated parts that could not be cleaned satisfactorily must be
– – packed in well sealed bags – – disposed of in a manner that complies with valid regulations for such waste removal
Operation · Picking up liquids

A dust test must be performed at least once every year by Makita service or a trained person. This test includes, for example, whether there is damage to the filter, the vacuum cleaner is sealed to the air and the control equipment works properly.
Disposal of filter elements, filter bags and disposal bags
Discard filter elements, filter bags and disposal bags in accordance with the national regulations.
Before transporting the dirt tank, close all the locks. Do not tilt the cleaner if there is liquid in the dirt tank. Do not use a crane hook to lift the cleaner.
Recycling the vacuum cleaner
As specified in European Directive 2012/19/EC on old electrical and electronic appliances, used electrical goods must be collected separately and recycled ecologically. Contact your local authorities or your nearest dealer for further information.
Our general conditions of business are applicable with regard to the guarantee. Subject to change as a result of technical alterations.
Spare parts and accessories
Description Order no.
Fleece filter bag 107418007
Exploded drawings and parts lists are available on our homepage: www.makita.com
Fault Cause Remedy ‡ Motor does not start > Fuse in mains plug has blown. • Reset the fuse. > Overload protection switch has
tripped.
> Power tool is defective or not
connected properly.
suction power control is to low.
upper section of the cleaner and the dirt tank is dirty/ defective.
> Filter bag is full. • See section “Replacing the filter bag”.

Fault Cause Remedy > Filter element is clogged. • See section “Cleaning the filter element” and “Replacing the filter element”. ‡ No suction power during wet
> Tank is full (floater closes the
suction opening).
too high.
For European countries only:
EC Declaration of Conformity
Makita declares that the following Machine(s): Designation of the Machine: Wet and dry vacuum cleaner Model No./Type: VC3012L Conforms to the following European Directives:
2006/42/EC, 2014/30/EU, 2011/65/EU They are manufactured in accordance with the following Standard or standardized documents:
EN 60335-1: 2012 + A11:2014, EN 60335-2-69:2012 The Technical file in accordance with 2006/42/EC is available from:
Makita Europe N.V., Jan-Baptist Vinkstraat 2, 3070 Kortenberg, Belgium
06.06.2016 Yasushi Fukaya
Director Makita Europe N.V., Jan-Baptist Vinkstraat 2, 3070 Kortenberg, Belgium
cleaning

EU/RU AU CH GB 230 V CDN Mains Voltage V 230 240 230 120
Mains frequency Hz 50 60 Power consumption / Rated current W / A 1200 840 / 7
Connected load for appliance socket W 2400 1200 1100 1750 600
Total connected load W 3600 2400 2300 2950 1440 Fuse A 16 10 13 15 Volume flow (air) m³/h (cfm) 222 (130) 192 (113)
Vacuum mbar / hPa (inH2O) 250 / 250 (100) 230 / 230 (92)
Sound pressure level at a distance of 1 m, ISO 3744 dB(A) 62 ±2
Sound level dB(A) 59 ±2 Hand-arm vibration m/s²
Power cord type H07RN-F 3G1,5 mm² SJTW-A AWG14/3 Protection class I Type of protection IPX4 Radio interference suppression level EN 55014-1
Tank volume l (UKgal / USgal) 30 (6,6 / 8,9)
Width mm (in) 385 (15,2) Depth mm (in) 485 (19,1) Height mm (in) 500 (19,7) Weight (net, most common application) kg (lb) 10 (22)
Technical data · Dust class L
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| ‡ Motor does not start | > Fuse in mains plug has blown. > Overload protection switch has tripped. | • Reset the fuse. • Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If it can not be started again, contact the Makita service department. | p.3 |
| ‡ Motor does not run in automatic mode | > Power tool is defective or not connected properly. | • Check that the power tool works or that the plug is inserted correctly. | p.3 |
| ‡ Reduced suction power | > Suction power selected with suction power control is to low. > Clogged suction hose/nozzle. > Seal/tank rim between the upper section of the cleaner and the dirt tank is dirty/ defective. > Filter bag is full. | • Set suction power in accordance with section “Suction power control”. • Clean suction hose/nozzle. • Clean/replace seal. • See section “Replacing the filter bag”. | p.3 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.