Symbols used to mark instructions
Before using the vacuum cleaner, always read the operating instruc- tions and keep them readily avail- able. Manuals are also available for download on the Makita website.
This symbol is used to mark safety instruc- tions that must be observed to prevent damage to the vacuum cleaner and its performance.
This symbol is used to mark safety instruc- tions that must be observed to prevent damage to persons.
This symbol in- dicates tips and instructions to simplify work and to ensure safe operation.
For your own safety The appliance must – only be used by persons, who
The use of the vacuum cleaner is subject to valid national regu- lations. Besides the operating instructions and the binding acci- dent prevention regulations valid in the country of use, observe recognized regulations for safety and proper use.
have been instructed in its correct usage and explicitly commis- sioned with the task of operating it – only be operated under supervi-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of expe- rience and knowledge.
Do not use any unsafe work techniques.
In case of emergency: Switch off the main switch and disconnect mains plug.
Children should be supervised to ensure that they do not play with the appliance.
Purpose and intended use The vacuum cleaners described in this operating manual are suitable for – sucking up dust and liquids – commercial use, e.g. in hotels,
The following materials should not be picked up by the vacuum cleaner: – hot materials (burning cigaret-
tes, hot ash, etc.) – flammable, explosive, ag-
schools, hospitals, factories, shops, offices and rental busi- nesses – separation of dust with an ex-
gressive liquids (e.g. petrol, solvents, acids, alkalis, etc.) – flammable, explosive dust
posure limit of greater than 0.1 mg/m³ (dust class M). Please observe regula- tions valid in your country.
(e.g. magnesium dust, etc.)
The appliance must – only be used indoors and not
outdoors – be protected against UV radi-
sion · ation

english When dust removers are used, the rate at which air is ex- changed in the room must be adequate if the exhaust air from the vacuum cleaner is blown into the room (please observe regu- lations valid in your country).
Before starting work, the operat- ing staff must be informed on – use of the vacuum cleaner – risks associated with the ma-
terial to be picked up – safe disposal of the picked
up material.
Precautions and safety regulations when using the vacuum cleaner
Inspect power cord regularly to detect signs of damage, e.g. cracks or ageing.
Check the rated voltage of the vacuum cleaner before con- necting it to the mains supply system. Ensure that the voltage shown on the rating plate corre- sponds to the voltage of the lo- cal mains power supply. If you are using an extension cord, use only those specified by the manufacturer or higher quality ones (see section 9.4 „Technical data“).
If the power cord is damaged, it must be replaced by the Service or an electrician to avoid danger before use of the vacuum clean- er is continued.
Use only the type of power cord specified in the operating man- ual.
It is recommended that the vac- uum cleaner should be connect- ed via a residual current circuit breaker. This stops the supply of electricity if the leakage cur- rent to earth exceeds 30 mA for 30 ms or it has an earth tester circuit.
Do not damage the power cord (e.g. by moving over it or pulling or crushing it).
Disconnect the power cord by pulling the plug only (do not pull or tug the power cord).
Inspect the vacuum cleaners to ensure that they are in proper condition. Plugs and couplings in power cords must at least have splash protection.
When using an extension lead, check the minimum cross-sec- tions of the cable:
Never use the vacuum cleaner if the filter element is damaged.
Arrange the electrical parts (sockets, plugs and couplings) and lay down the extension lead so that the protection class is maintained.
If foam develops or liquid emerges, stop work immediately and empty the dirt tank.
Never spray water on to the upper section of the vacuum cleaner. Danger for persons, risk or short-circuiting.
Regularly clean the built in level indicator hose to limit the wa- ter level and check that it is not damaged.
Observe the latest edition of the IEC regulations.
See section 5 for information on handling liquids and (hazard- ous) dust.
Before start-up · Electrical components · Picking up liquids

english Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only.
Before plugging an appliance into the appliance socket: 1. Switch off the vacuum clean- er 2. Switch off the appliance to be connected.
Maintenance, cleaning and repair
Only carry out maintenance work described in the operating instructions.
– clean the outside of the vac-
uum cleaner, wipe it clean or pack the vacuum cleaner in well sealed packaging – and avoid spreading depos-
Always pull out the mains plug before cleaning and mainte- nance of the vacuum cleaner.
ited harmful dust.
During maintenance and repair work all contaminated parts that could not be cleaned satisfacto- rily must be: – packed in well sealed bags – disposed of in a manner that
During maintenance and clean- ing, handle the vacuum cleaner in such a manner that there is no danger for maintenance staff or other persons.
complies with valid regula- tions for such waste removal.
In the maintenance area – use filtered compulsory ven-
tilation – wear protective clothing – clean the maintenance are
A dust test must be performed at least once every year by the Service or a trained person. This test includes, for exam- ple, whether there is damage to the filter, the vacuum cleaner is sealed to the air and the control equipment works properly.
so that no harmful substanc- es get into the surroundings.
Before removing the vacuum cleaner from the area contami- nated with harmful substances:
Disposal of filter elements, fil- ter bags and disposal bags
Discard filter elements, filter bags and disposal bags in ac- cordance with the national regu- lations.
Accessories and spare parts Use only the brushes supplied with the vacuum cleaner or specified in the operating manu- al. The use of other brushes can adversely affect safety.
Use only original accessories and spare parts (see section 9.5). The use of other parts can adversely affect safety.
2.1 Purpose This cleaner is suitable to pick up dry, nonflammable dust, liq- uids, sawdust and hazardous dusts with maximum room con- centration values ≥ 0.1 mg/m3 (dust class M).
Depending on how hazardous the dust is, the cleaner must be fitted with appropriate filters. See table in section 5.1.1.
Tool socket

english 2.2 Operating elements See fold-out page at the front of these operating instructions.
3 Retaining clamp 4 Dirt tank 5 Grip to empty tank 6 Inlet fitting 7 Tool socket 8 Hose diameter setting
1 Handle with cable hook 2 Switch with suction power control
3.1 Assembling the cleaner
On delivery some of the accesso- ries are lying in the tank and must be removed before the vacuum cleaner is used for the first time. Remove the upper section of the vacuum cleaner: The mains plug should not be in- serted into a socket.
4.1 Connections 4.1.1 Connecting the suction hose
The suction hose diameter must suit the position of the switch in order to pick up dry, nonflam- mable dust with maximum room concentration values.
4.1.2 Electrical connection The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply.

4.1.3 Connecting electrical appliances
To comply with regulations, only ap- proved dust producing tools should be connected. The maximum power consumption of the connected power tool is stat- ed in section 9.4 “Technical data”.
4.2.2 Switch position „auto“ Before switching the switch to position „auto“, ensure that the tool connected to the appliance socket is switched off.
The hose diameter and the setting for the suction hose diameter must be the same.
setting ø27 ø27 ø32 ø32 ø36 ø36 ø50 ø50
4.2.3 Suction power control The motor speed and the suc- tion power can be varied with the suction power control. This allows precise adaptation of the suction power for different cleaning tasks.
4.3 Check volume flow monitor
Before picking up dust with maxi- mum room concentration values:

english 4.4 Acoustic warning For safety reasons, an acoustic warning sounds if the air speed in the suction hose drops to be- low 20 m/s. See section “Trou- bleshooting”.

4.5 Cleaning the filter element
To ensure that suction performance is always at its best, the filter ele- ment is automatically cleaned dur- ing operation. We recommend com- plete cleaning if the filter element becomes extremely dirty.
After picking up harmless dust us- ing the waste bag.
of your hand. 3. Turn the switch to position „I“ and let the cleaner operate for approx. 10 seconds with the suction hose opening closed.
5.1 Techniques If used correctly, additional ac- cessories, suction nozzles and suction hoses can enhance the cleaning action and reduce the cleaning effort.
Effective cleaning is achieved if you follow just a few guidelines in combination with your own practical experience in special fields. Here are some basic tips.
5.1.1 Picking up dry substances
The suction hose diameter must suit the position of the switch in order to pick up dry, nonflam- mable dust with maximum room concentration values. There must always be a safety filter bag in the tank before dry substances with maximum room concentration values are picked up. See section 9.5 “Accesso- ries” for ordering number.
posal of the picked up material is then simple and hygienic.
After picking up liquids, the filter element is wet. A damp filter el- ement clogs more quickly when dry substances are picked up. For this reason the filter element should be washed and dried or replaced by a dry element be- fore dry substances are picked up.
Do not pick up flammable substanc- es.
To pick up harmless dust we recommend the use of a waste bag. See section 9.5 “Accesso- ries” for ordering number. Dis-
Always use a filter bag/waste bag that is suitable for the type of dust (see table):


5.1.2 Picking up liquids Before liquids are picked up, always remove the filter bag/ waste bag and check that the water level limit works properly. (See section 7.2.3 “Replacing the filter element“.)
If foam appears, stop work im- mediately and empty the tank.
To reduce the amount of foam, use foam killer Foam-Stop (see section 9.5 „Accessories“ for or- der number).
The use of a separate filter el- ement or filter screen is recom- mended.
Do not pick up flammable substances.
6.1 Switching the vacuum cleaner off and storage
1. After picking up hazardous dust, vacuum clean the out- side of the cleaner. 2. Switch off the vacuum clean- er and pull the mains plug out of the socket. 3. Wind up the power cord and hang it on the handle. 4. Empty the tank and clean the vacuum cleaner. 5. After picking up liquids: Store the upper section of the cleaner separately so that the filter element can dry. 6. Store the vacuum cleaner in a dry room where it is pro- tected from unauthorized use.

english

7.1 Maintenance plan

7.2.4 Emptying dirt tank after picking up liquids =
7.2 Maintenance work 7.2.1 Replacing the waste bag

Clean the filter element before re- placing the waste bag - see section 4.5.

During the following work, en- sure that dust is not unnecessarily spread around. Wear a P2 breath- ing mask.
7.2.2 Replacing the filter bag 1. Open the retaining clamps and remove the upper sec- tion of the cleaner from the dirt tank. 2. Carefully remove the filter bag connection from the inlet fitting. 3. Close the filter bag connec- tion with the slide. 4. Dispose of the filter bag in accordance with legal regu- lations. 5. Place a new filter bag into the cleaned tank as described in the instructions (printed on the filter bag).

During the following work, en- sure that dust is not unnecessarily spread around. Wear a P2 breath- ing mask.
english

english 7.2.3 Replacing filter element 1. Open the retaining clamps and remove the upper sec- tion of the cleaner from the dirt tank. Lay the upper sec- tion of the cleaner down with the filter element facing up- wards. Do not place the up- per section of the cleaner on the guard (1) and do not damage the filter element. 2. Open the bar handle (2) and remove it. 3. Remove the filter holder (3). 4. Carefully remove the filter el- ement. 5. Clean the filter seal (4). Check it for damage and re- place it if necessary. 6. Check the antistatic clamp (5) for damage and have it replaced by Service if neces- sary. 7. Check that the control flap (6) for filter cleaning works properly. The control flap should move back and for- wards easily. 8. Clean the level hose (7). 9. Fit a new filter element. 10. Fit the filter holder. Ensure that it is in the correct posi- tion. 11. Fit bar and close bar handle. 12. Dispose of the used filter ele- ment in accordance with le- gal regulations.
During the following work, en- sure that dust is not unnecessarily spread around. Wear a P2 breath- ing mask.

Never use the vacuum cleaner without a filter.
7.2.4 Emptying dirt tank 1. Remove the upper section of cleaner from the dirt tank. 2. Using one hand, take hold of the dirt tank underneath and tip out the dirt. 3. Dispose of the dirt in accordance with legal regulations. 4. Clean the rim of the tank before fitting the upper section of clean- er. Before reinserting the suction hose: 5. Clean the inlet fitting and hose collar.
Only after picking up harmless dust without a filter bag.

‡ Motor does not start > Fuse of the mains socket has blown.
> Overload protection switch has tripped.
> Self-acting carbon brush is worn.
‡ Motor does not run in auto- matic mode
> Power tool is defective or not connected properly.
> The power rating of the elec- trical tool is too low.
‡ The acoustic warning sounds. (Reduced suction power)
> Suction power selected with suction power control is too low.
> Hose diameter is not right for switch position.
> Clogged suction hose/nozzle. • Clean suction hose/nozzle
> Filter bag is full. • See section 7.2.2 „Replacing filter bag“.
> Filter element is clogged. • See section 4.5 „Cleaning filter element“ and 7.2.3 „Replacing filter element“.
> Defective cleaning mecha- nism
‡ The vacuum cleaner switches off during wet cleaning
> Tank is full. • Switch off the cleaner. Empty the tank.
‡ Voltage fluctuations > Impedance of power supply is too high.
Fault Cause Remedy

9.1 Recycling the vacuum cleaner
Make the old cleaner unusable immediately.
In accordance with European guideline 2012/19/EG on Waste Electrical and Electronic Equip- ment all used up electrical appli- ances must be collected sepa- rately and supplied to a environ- mentalfair recycling.
Do not dispose electrical ap- pliances as unsorted domestic waste.
Contact your local authorities or your nearest dealer for further information.
9.2 Guarantee Our general conditions of busi- ness are applicable with regard to the guarantee. Subject to change as a result of technical advances.
9.3 Tests and approvals The vacuum cleaners have been tested as specified in EN 60335-2-69 (2012) including ap- pendix AA. All the requirements were fulfilled for equipment in dust class M.
The vacuum cleaners must be inspected regularly in accord- ance with national accident pre- vention regulations (in Germany as specified in BGV A3 and DIN VDE 0701 Part 1 and Part 3, at regular intervals and after re- pairs or modifications).
A dust test must be performed at least once every year by the manufacturer or a trained per- son. This test covers, for exam- ple, whether there is damage to the filter, the vacuum cleaner is sealed to the air and the control equipment works properly.

english 9.4 Technical data

EU AU CH GB 110 V GB 230 V USA
Power consumption / Rated current Watt / A 1200 1000 1040 / 8.7
Connected load for appliance socket Watt 2400 1200 1100 1750 2000 400
Total connected load/fuse Watt 3600 2400 2300 2750 3000 1440
Volume flow (air) m³/h / l/min / cfm 216 / 3600 / 127 186 / 3100 / 109 192 / 3200 / 113
Sound pressure level at a distance of 1 m, ISO 3744 dB(A) 60 ± 2
Power cord type H07RN-F 3G1,5 mm² H07BQ-F 3G2,5 mm² H07RN-F 3G1,5 mm² SJTW-A AWG14/3
Tank volume l / UKgal / USgal 45 / 9.9 / 12
9.5 Accessories

Description Order No. Filter bag (5 pcs.) W 302001138 Waste bag (5 pcs.) W 302001311 Filter element W 302000751 Foam-Stop (6 x 1 l) W 8469
Suction hose, antistatic, ø27 mm x 3.5 m W 15325

15
2.1 Verwendungszweck 17 2.2 Bedienelemente 18
3 Vor der Inbetriebnahme
3.1 Sauger zusammenbauen 18
4 Bedienung / Betrieb
4.1 Anschlüsse 18 4.1.1 Saugschlauch anschließen 18 4.1.2 Elektrischer Anschluss 18 4.1.3 Elektrogerät anschließen 19 4.2 Sauger einschalten 19 4.2.1 Schalterstellung „ I “ 19 4.2.2 Schalterstellung „auto“ 19 4.2.3 Saugkraftregulierung 19 4.3 Volumenstrom-Überwachung prüfen 19 4.4 Akustisches Warnsignal 20 4.5 Filterelement abreinigen 20
5 Anwendungsgebiete und Arbeitsmethoden
5.1 Arbeitstechniken 20 5.1.1 Trockene Stoffe saugen 20 5.1.2 Flüssigkeiten saugen 21
6 Nach der Arbeit
6.1 Sauger ausschalten und aufbewahren 21
7.1 Wartungsplan 22 7.2 Wartungsarbeiten 22 7.2.1 Entsorgungssack wechseln 22 7.2.2 Filtersack wechseln 22 7.2.3 Filterelement wechseln 23 7.2.4 Schmutzbehälter entleeren 23
8 Behebung von Störungen
24
9.1 Gerät der Wiederverwertung zuführen 25 9.2 Garantie 25 9.3 Prüfungen und Zulassungen 25 9.4 Technische Daten 26 9.5 Zubehör 26
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| ‡ Motor does not start | > Fuse of the mains socket has blown. > Overload protection switch has tripped. > Self-acting carbon brush is worn. | • Connect mains fuse. • Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If the cleaner can- not be started again, contact the service department. • Have carbon brushes changed by Service. | p.10 |
| ‡ Motor does not run in auto- matic mode | > Power tool is defective or not connected properly. > The power rating of the elec- trical tool is too low. | • Check that the power tool works or that the plug is insert- ed correctly. • Note that minimum power rat- ing is P>40W | p.10 |
| ‡ The acoustic warning sounds. (Reduced suction power) | > Suction power selected with suction power control is too low. > Hose diameter is not right for switch position. > Clogged suction hose/nozzle. > Filter bag is full. > Filter element is clogged. > Defective cleaning mecha- nism | • Set suction power in accord- ance with section 4.2.3. „Set- ting suction power“. • Set correct switch position for hose diameter. • Clean suction hose/nozzle • See section 7.2.2 „Replacing filter bag“. • See section 4.5 „Cleaning filter element“ and 7.2.3 „Replacing filter element“. • Contact Service | p.10 |
| ‡ The vacuum cleaner switches off during wet cleaning | > Tank is full. | • Switch off the cleaner. Empty the tank. | p.10 |
| ‡ Voltage fluctuations | > Impedance of power supply is too high. | • Connect the cleaner to another socket closer to the fuse box. Voltage fluctuations over 7% should not occur if the imped- ance at the transfer point is ≤ 0.15 Ω . | p.10 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.