Dimplex SmartRad Fan Convector SRX 080M, SRX 120M, SRX 140M & SRX 180M
FR NO DE FI NL PL
The product complies with the European Safety Standards EN60335-1 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2
and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
srx_ba 01/11/C



590 MIN 535 150 MIN 150 MIN 235 MIN






Power Output

PLEASE STORE THESE INSTRUCTIONS IN A SAFE PLACE.
Important safety information The air inlet and outlet guards must not be covered or blocked. Before performing maintenance work on the device, discon- nect it from the power supply. THE DEVICE MUST BE GROUNDED. The heater must not be installed directly below a permanently installed socket. Combustible materials or liquids and other highly flammable furnishings must be kept away from the heater. For the necessary minimum distances (in mm), see fig. 4. Install the device such that it is not possible for someone in the bath or shower to touch the control elements. The heater must not be operated in very dusty areas. This device is not suitable for children or persons who cannot use the device safely as a result of physical or mental disability or reduced perception without the assistance or supervision of another person. Children should be supervised to ensure they do not play with the device.

A warning symbol is attached to the heater. This in- dicates that the device must not be covered. The operating instructions belong to the device and must be stored in a safe place. In case of the owner changes, the operating instructions should be passed on to the new owner. IMPORTANT – If the mains cable of the device is damaged, it must be replaced by the manufacturer, a customer service representative or a similarly qualified person. Always ensure proper operation. Device description
Remove packaging material. Unscrew the four fixing screws from underside of device (see fig. 2) to remove casing cover. Store the casing cover such that it cannot be damaged during installation. Fixing to the wall
The SmartRad model is a fan convector for heating living spaces. The fan convector is intended for connection to a central heat- ing system. The fan convector is suitable for use in heat pump systems, but it can also be operated in conjunction with other heating systems, e.g. with oil or gas fires. The device draws in air from the underside. This is heated up in the heat exchanger and discharged at the top.
For drywalls, use suitable fixing material (not supplied)! Draw and drill four holes on a sturdy wall as shown in fig. 4. All dimensions are in mm. Insert dowels and pre-fit the two top screws (don't completely screw in yet). Hang device on the two top screws. Insert and tighten the two bottom screws, then tighten the two top screws. Hydraulic connection
Fig. 1: (a) Casing cover (b) Control panel (c) Air outlet guard (d) 1 m connection cable
To ensure a sufficient heating water flow rate through the fan convectors, observe the following points:
Fan convectors may only be used in central heating systems with a closed control circuit. The heating system must be operated as a dual-pipe system. The devices must be of a sufficient rating such that they can compensate for heat losses in the room.
- The devices are not suitable for installation in single-pipe
systems. - The nominal width of the connection pipe must have a
minimum diameter of 15 mm. - If the devices are installed in a heating system with various
heat distribution systems (e.g. underfloor heating), a sepa- rate circuit is required to guarantee a sufficient water flow rate. - For optimum operation (heat output) of the fan convectors,
Technical data

a hydraulic balance is required on the heating system.
external voltage (via a timer contact or pilot device with pro- gramming cassette). Final installation
Fig. 5 shows the various hydraulic connection options on the device. The recommended flow and return connections are shown in fig. 5 and fig. 4 (below). The heating pipes can be laid in the floor or in the wall. The device is supplied with two cop- per pipes with a diameter of 15 mm that are fitted on the heat exchanger at the factory. Before and during filling of the heating system, all pipe connec- tions must be checked for leaks. During filling, the bleeder valve (see fig. 4) must be open such that air can escape from the de- vice. If necessary, bleed again following commissioning (circulat- ing pump running). Electrical connection
Fit casing cover following completion of installation work. To do this, screw in the four fixing screws on the underside of the de- vice, see fig. 2. Operation
The control panel is shown in fig. 3. The individual elements have the following meaning: A – Operating mode button B – On/off indicator C – Manual mode indicator D – Automatic mode indicator E – Fan level button F – Low fan level indicator G – Medium fan level indicator H – High fan level indicator J – Thermostat setting wheel K – Cover for programming cassette slot Manual operation
WARNING: The device must be grounded. WARNING – phase conductor (brown) and neutral conductor (blue) must not be swapped as this may cause malfunctions. The electrical connection should have a supply voltage of ~230- 240V, 50 Hz. The device must be installed by a qualified electrician in compli- ance with the existing standards and local installation guide- lines. Before performing installation, ensure that the power supply is switched off. The device is equipped with a flexible 1 m connection cable (4 x 0.75 mm²), which can be used to connect the heater directly to the power supply via a suitable wall socket. In the electrical supply line, fit a circuit breaker for each pole with a contact opening width of at least 3 mm. Automatic fuses are also permitted as separators. Automatic fuses should have a delayed tripping characteristic.
Press the button once or several times until the yellow indicator lights up. Press the button once or several times to select the de- sired fan level (fan speed). The set fan level is indicated by the red indicator (1, 2, 3). Set the desired room tempera- ture with the knob. The set fan level is switched on and off depending on the room temperature. The temperature re- duction is forwarded to any downstream devices via the control conductor. Automatic mode (eco)
Conductor configuration of the connection cable: Brown: 'L' – supply voltage phase conductor Blue: 'N' – supply voltage neutral conductor Green/yellow: 'PE' grounding conductor Black: control conductor (temperature reduction; on/off)
Press the button once or several times until the red eco indicator lights up. Set the desired room temperature with the knob. Depend- ing on the current room temperature and the target tem- perature set on the thermostat, the electronics calculate which of the three fan levels (fan speeds) to use. The elec- tronics select the required fan level depending on the dif- ference between the current room temperature and the de- sired target temperature. If necessary, the number of possible fan levels can be reduced. For instance, to limit the fan levels to a maximum of 2, press the button once or several times until the red 2 indicator lights up. Operation with a programming cassette or a timer can only take place in automatic mode (eco). If there is a control signal, the green eco indicator lights up. Fault indication
For circuit diagram, see fig. 6. Control conductor
The black control conductor has the following functions:
Lowering temperature using an external timer or switch By activating the control conductor, see fig. 6 on the left, the set target temperature on the device is lowered. The temperature reduction is forwarded to any downstream devices via the control conductor.
Operation with programming cassette The control signals of the programming cassette, which is plugged into the pilot device, are forwarded to any downstream devices via the control conductor, see fig. 6 on the right. The control conductor does not have to be in phase with the supply connection. If the control conductor is not used, it must be properly insulated. WARNING – if you switch over to controlled operation, the mains voltage is on this conductor! WARNING – do not ground the control conductor. When taking out of service, e.g. for maintenance work, ensure that both the mains supply and the control conductor are dis- connected from the power supply, because this may result in
If the water temperature is too low, operation of the device is interrupted and the red indicator flashes. In this case, check that the heating system and circulating pump are operating cor- rectly. For more information, please refer to the "Troubleshoot- ing" chapter.

Operation with air/water heat pumps
When operating with an air/water heat pump, particularly when temperatures are low outside, the heat pump's buffer tank must be at a temperature of at least 14°C to ensure that the heat pump evaporator can defrost. You should therefore en- sure that thawing has taken place if necessary before opening the valves to the heating circuit. Troubleshooting
The heater must be switched off and cooled for cleaning. The surfaces of the heater can be cleaned by wiping with a soft, damp cloth and then dried. Do not use abrasive powder or fur- niture polish to clean as these may damage the surface. Maintenance – to be performed by a specialist
Dust or lint that collects inside the heater must be removed at regular intervals. To do this, disconnect the device from the power supply, loosen the 4 fixing screws on the underside of the casing and carefully remove the casing cover. Remove dirt with a soft brush or a vacuum cleaner. Build-up of air in the heat exchanger can be remedied by open- ing the bleeder valve (fig. 4). Warranty
The following causes can result in the fan convector producing insufficient heat:
We offer a two-year warranty for this device in accordance with our warranty conditions.
Glen Dimplex Deutschland GmbH Phone +49 9221 709564 Am Goldenen Feld 18 Fax +49 9221 709589 D-95326 Kulmbach www.glendimplex.de Subject to modifications EN 01/11/C
Cleaning outer surfaces