DE
Dimplex logo
Offizielle Bedienungsanleitung

Dimplex SRX 120C

36 Seiten·3 MB·Konvektor·PDF·ENITJA
Dimplex SRX 120C
Inhaltsverzeichnis 4 Abschnitte Seite1 · Seite2 · Seite3 · Seite4 AnzeigenAusblenden
Page 1 of the Dimplex SRX 120C user manual — Seite1
Seite 1 · Zum Vergrößern klicken
Seite 1
Dimplex SRX 120C — Seite1 diagram (page 1)
Abb. 1 · Seite1
Page 2 of the Dimplex SRX 120C user manual — Seite1
Seite 2 · Zum Vergrößern klicken
Seite 2
Dimplex SRX 120C — Seite1 diagram (page 2)
Abb. 2 · Seite1
Page 3 of the Dimplex SRX 120C user manual — Seite1
Seite 3 · Zum Vergrößern klicken
Seite 3
Dimplex SRX 120C — Seite1 diagram (page 3)
Abb. 3 · Seite1
Page 4 of the Dimplex SRX 120C user manual — Seite1
Seite 4 · Zum Vergrößern klicken
Seite 4
Dimplex SRX 120C — Seite1 diagram (page 4)
Abb. 4 · Seite1
Page 5 of the Dimplex SRX 120C user manual — EN
Seite 5 · Zum Vergrößern klicken
Seite 5

- 1 - Dimplex SmartRad fan convector Models: SRX 070C, SRX 120C & SRX 160C

EN

PLEASE STORE THESE INSTRUCTIONS IN A SAFE PLACE.

Important safety information The air inlet and outlet guards must not be covered or blocked. Before performing maintenance work on the device, discon- nect it from the power supply. THE DEVICE MUST BE GROUNDED. The heater must not be installed directly below a permanently installed socket. Combustible materials or liquids and other highly flammable furnishings must be kept away from the heater. For the necessary minimum distances (in mm), see fig. 4. Install the device such that it is not possible for someone in the bath or shower to touch the control elements. The heater must not be operated in very dusty areas. This device is not suitable for children or persons who cannot use the device safely as a result of physical or mental disability or reduced perception without the assistance or supervision of another person. Children should be supervised to ensure they do not play with the device.

The devices must be of a sufficient rating such that they can compensate for heat losses in the room. The cooling function will only work in suitable systems, e.g. in combination with a reversible heat pump with both heat- ing and cooling modes. Technical data

SRX 070CSRX 120CSRX 160C Setting range of thermostat (°C)5 - 30 Flow temperature (°C) in heating mode> 25 Maximum permissible flow temperature (°C)85 Flow temperature (°C) in cooling mode< 20 Permissible operating overpressure (MPa)1 Pressure drop (kPa)11,313,113,7 Air volume flow (m³/h)3228410540 2125225300 160120160 Sound pressure level at 1 m (dB(A))347 238 127 Nominal voltage~ 230-240 V, 50 Hz Power consumption of fan (W)3265650 2193633 1162423 Standby energy consumption (W)< 1 Protection categoryIP 20 Volume of heat exchanger (ml)230385555 Dimensions W x H x D (mm)503 x 530 x 145740 x 530 x 145911 x 530 x 145 Weight (kg)121517,5
Dimplex SRX 120C — EN diagram (page 5)
Abb. 5

A warning symbol is attached to the heater. This in- dicates that the device must not be covered. The operating instructions belong to the device and must be stored in a safe place. If the owner changes, the op- erating instructions should be passed on to the new owner. IMPORTANT – If the mains cable of the device is damaged, it must be replaced by the manufacturer, a customer service representative or a similarly qualified person. Always ensure proper operation. Device description

The SmartRad model is a fan convector for heating or cooling living spaces. The fan convector is intended for connection to a central heating system. The fan convector is designed for use in heat pump systems, but when being used for heating only it can also be operated in conjunction with other heating systems, e.g. with oil or gas boilers. The device draws in air from the under- side. This is heated or cooled, depending on the mode of opera- tion, in the heat exchanger and discharged at the top.

For more technical data, refer to table in fig. 7. Installation preparation

Remove packaging material. Unscrew the four fixing screws from underside of device (see fig. 2) to remove casing cover. Store casing cover such that it cannot be damaged during installation. Fixing to the wall

Fig. 1: (a) Casing cover (b) Control panel (c) Air outlet guard (d) 1 m connection cable

For drywalls, use suitable fixing material (not supplied)! Draw and drill four holes on a sturdy wall as shown in fig. 4. All dimensions are in mm. Insert dowels and pre-fit the two top screws (don't completely screw in yet). Hang device on the two top screws. Insert and tighten the two bottom screws, then tighten the two top screws.

Fan convectors may only be used in central heating systems with a closed control circuit. The heating system must be operated as a dual-pipe system.

Page 6 of the Dimplex SRX 120C user manual — Seite1
Seite 6 · Zum Vergrößern klicken
Seite 6

- 2 - Hydraulic connection

To ensure a sufficient water flow rate through the fan convec- tors, observe the following points:

By activating the control conductor, see fig. 6.1, the set tem- perature on the device is lowered or raised depending on the selected mode. See also "Changing automatically the set temperature" The temperature change is forwarded to any downstream de- vices via the control conductor.

- The devices are not suitable for installation in single-pipe

systems. - The nominal width of the connection pipe must have a

minimum diameter of 15 mm. - If the devices are installed in a heating system with various

If a programming cassette is used, the control signal from the cassette, which is plugged into the pilot device, is forwarded to any downstream devices; see fig. 6.2. The control conductor does not have to be in phase with the supply connection. If the control conductor is not used, it must be properly insulated. WARNING – if you switch over to controlled operation, the mains voltage is on this conductor! WARNING – do not ground the control conductor. When taking out of service, e.g. for maintenance work, ensure that both the mains supply and the control conductor are dis- connected from the power supply, because this may result in external voltage (via a timer contact or pilot device with pro- gramming cassette). Final installation

heat distribution systems (e.g. underfloor heating), a sepa- rate circuit is required to guarantee a sufficient water flow rate. - For optimum operation (heat output) of the fan convectors,

a hydraulic balance is required on the heating system.

Fig. 5 shows the various hydraulic connection options on the device. The recommended flow and return connections are shown in fig. 5 and fig. 4. The heating pipes can be laid in the floor or in the wall. The device is supplied with two copper pipes with a diameter of 15 mm that are fitted on the heat exchanger at the factory. Before and during filling of the heating system, all pipe connec- tions must be checked for leaks. During filling, the bleeder valve (see fig. 4) must be open such that air can escape from the de- vice. If necessary, bleed again following commissioning (circulat- ing pump running). Connect the condensate pipe supplied to the outlet nozzle and route to a suitable outlet with a gradient of at least 5°. Electrical connection

Fit casing cover following completion of installation work. To do this, screw in the four fixing screws on the underside of the de- vice, see fig. 2. Operation

WARNING – The device must be grounded! WARNING – Phase conductor (brown) and neutral conductor (blue) must not be swapped as this may cause malfunctions. The electrical connection should have a supply voltage of ~230- 240V, 50 Hz. The device must be installed by a qualified electrician in compli- ance with the existing standards and local installation guide- lines. Before performing installation, ensure that the power supply is switched off. The device is equipped with a flexible 1 m connection cable (4 x 0.75 mm²), which can be used to connect the heater directly to the power supply via a suitable wall socket. In the electrical supply line, fit a circuit breaker for each pole with a contact opening width of at least 3 mm. Automatic fuses are also permitted as separators. Automatic fuses should have a delayed tripping characteristic. Conductor configuration of the connection cable: Brown: 'L' – supply voltage phase conductor Blue: 'N' – supply voltage neutral conductor Green/yellow: 'PE' – grounding conductor Black: control conductor (temperature reduction; on/off) For circuit diagram, see fig. 6.1 resp. fig. 6.2.

The control panel is shown in fig. 3. The individual elements have the following meaning: A – Operating mode button B – On/off indicator C – Cooling mode indicator D – Heating mode indicator E – Fan level button F – Low fan level indicator G – Medium fan level indicator H – High fan level indicator J – Thermostat setting wheel K – Cover for programming cassette slot Heating mode

Press the button once or several times until the red in- dicator lights up. Set the desired room temperature with the setting wheel. Depending on the current room temperature and the tem- perature set on the thermostat, the electronics calculate which fan level (fan speed) to use. There are 3 possible fan levels. If necessary, the number of pos- sible fan levels can be reduced. For instance, to limit the fan levels to a maximum of 2, press the button once or sev- eral times until the red 2 indicator lights up.

Control conductor

Page 7 of the Dimplex SRX 120C user manual — Seite1
Seite 7 · Zum Vergrößern klicken
Seite 7

- 3 - Cooling mode

The cooling function is only available if cooling mode has been set on the heat pump. Press the button once or several times until the yellow indicator lights up. Set the desired room temperature with the setting wheel. Depending on the current room temperature and the tem- perature set on the thermostat, the electronics calculate which fan level (fan speed) to use. There are 3 possible fan levels. If necessary, the number of pos- sible fan levels can be reduced. For instance, to limit the fan levels to a maximum of 2, press the button once or sev- eral times until the red 2 indicator lights up. Changing automatically the set temperature

The following causes can result in the unit producing insufficient output:

  • Indicator flashes: Insufficient flow temperature. See "Fault indication"
  • Indicator , flashes: Set temperature automatically lowered or raised. See "Changing automatically the set temperature"
  • Air trapped in heat exchanger: Disconnect device from power supply, remove casing and bleed heat exchanger. For position of bleeder screw, see fig. 4.
  • Insufficient water flow rate through device: Adjust flow rate (hydraulic balance). To do this, close thermostat valves on the other heaters.
  • Dirt on heat exchanger: Clean heat exchanger, see "Maintenance". Cleaning outer surfaces

You can change the set temperature automatically using a suit- able programming cassette or by directly activating the control conductor, for example with an external timer. How the set temperature is changed depends on the selected operating mode: - In heating mode the set temperature is lowered - In cooling mode the set temperature is increased If there is a control signal, then depending on the selected mode, either the indicator lamp (heating) or the indica- tor lamp (cooling) flashes. The temperature change is forwarded to any downstream de- vices via the control conductor. Fault indication

The heater must be switched off and cooled for cleaning. The surfaces of the heater can be cleaned by wiping with a soft, damp cloth and then dried. Do not use abrasive powder or fur- niture polish to clean as these may damage the surface. During Installation: If the appliance is being installed in a dusty environment we recommend covering the appliance to prevent the ingress of dust. Maintenance – to be performed by a specialist

If the flow temperature is not within the required range (see ta- ble under "Technical data"), operation is interrupted and the red indicator flashes. In this case you should check that the settings of the heating system and circulating pump are correct and that they are work- ing properly. For more information, please refer to the "Trou- bleshooting" chapter. Operation with air/water heat pumps

Dust or lint that collects inside the heater must be removed at regular intervals. To do this, disconnect the device from the power supply, loosen the 4 fixing screws on the underside of the casing and carefully remove the casing cover. Remove dirt with a soft brush or a vacuum cleaner. Build-up of air in the heat exchanger can be remedied by open- ing the bleeder valve (fig. 4). Warranty

When operating with an air/water heat pump, particularly when temperatures are low outside, the heat pump's buffer tank must be at a temperature of at least 14°C to ensure that the heat pump evaporator can thaw. You should therefore ensure that thawing has taken place if necessary before opening the valves to the heating circuit.

We offer a two-year warranty for this device in accordance with our warranty conditions.

United Kingdom Dimplex – a division of the GDC Group Millbrook House Phone +44 0845 600 5111 Grange Drive, Hedge End Fax +44 0148 977 3050 Southampton, Hants, SO30 2DF www.dimplex.co.uk

Republic of Ireland Dimpco Ltd Airport Road Phone (+353) 01 842 839 Cloghran Fax (+353) 01 842 839 Co. Dublin www.dimpco.ie Subject to modifications

Troubleshooting

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Dimplex SRX 120C stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Dimplex SRX 120C

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Dimplex SRX 120C PDF-Anleitung

36 Seiten·3 MB·Konvektor·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…