Benutzeranleitung / Produktwartung Blood Glucose Meter des Produzenten Bayer HealthCare
Zur Seite of 44
For Use With Ascensia ® C ONTOUR ® Blood Glucose Meter and Ascensia ® M ICROFILL ® T est Strips User Guide.
T h a n k y o u f o r c h o o s i n g t h e A s c e n s i a ® C O N T O U R ® Bl oo d Gl uc o se Mo n it or i ng Sy s te m! W e ar e pr ou d to be your partner in helping you manage your diabetes. Our goal is to make this the simplest, most straightforward meter you will ever use.
Y our T esting T ools 2 Y our Meter Display 3 Y our Meter Features 4 Symptoms of High or Low Blood Glucose 5 Important Things to Know 6 Before Y ou Begin 7 Getting Ready to T est 8 Getting the Blood D.
2 Important Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Y our Ascens ia ® C ONTO UR ® Meter: Y our Ascens ia ® M I CR OFI LL ® T est Strip: Grey Electr ode End: The end of the test strip that is inserted into the test strip port on the meter with the grey end facing up.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) 3 Important www .ascensia.co.uk Y our Meter Display Th e pi ct ur e bel ow sho ws all the s ymbo ls tha t wi ll a ppea r on you r me te r di sp la y . Whe n the me te r is of f, pr ess an d co nt in ue hol di ng the ▲ or ▼ button.
4 Important Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Y our Meter Features Programmed: Y our Ascensia C ONTOUR Meter has been preset at the factory with the standard date, time, and meter features used wher e you live.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) 5 Important www .ascensia.co.uk Symptoms of High or Low Blood Glucose Y ou can better understand your test r esults by being awar e of the symptoms of high or low blood glucose; this will also help you decide what to do if your results seem unusual.
6 Important Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Important Things to Know Y our Asc ens ia C O NTO UR Blo od Gl uco se Me ter is specifi c for glucose and has been referenced to plasma /s erum values.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) 7 Important www .ascensia.co.uk Before Y ou Begin 1. Have all the materials you will need ready before you b e g in t es t in g.
T esting 8 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Getting Ready to T est: Read the Ascensia M ICROLET Lancing Device insert for complete instructions. Re mov e the e ndc ap f ro m the Asc ens ia M ICROLET Lanci ng Device.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) T esting 9 www .ascensia.co.uk Replace the device endcap. Remove a test strip from the bottle. T ightly close the bottle lid immediately after you have removed the test strip. NOTE: Check the expir y and dis- card dates.
Shallow Deep Puncture Puncture T esting 10 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Getting the Blood Drop: Fingertip T esting— The depth of the puncture depends upon the adjustable endcap setting you choose and the amount of pressure applied to the puncture site.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) T esting 11 www .ascensia.co.uk Getting the Blood Drop Multiple Site T esting— Read the lancing device insert for complete instructions. Blo od samp les for glu cos e testi ng m a y b e t a k e n f r om si te s o t h e r t h a n yo ur fi ng ert ip s.
T esting 12 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk I mm edi ate ly touch the tip o f th e te s t st r i p to th e dr op of blood. The blood is pul led into the tes t stri p through the tip. Do not press the tip against the skin or place the blood on top of the test strip.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) T esting 13 www .ascensia.co.uk T o tur n your meter of f, simply remove the test strip. Carefully dispose of the used test strip.
T esting 14 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk T o remove the used lancet: Place the protective cap on a fl at surface with the Bayer lo go fa cing d ow n. R em ov e t he endcap. (Do not use the same endcap on another person.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Help 15 www .ascensia.co.uk WHA T YOU SEE WH A T IT MEA NS WHA T YOU SHOULD DO (will remain on the display ) Lo w b at te r ie s Replace the batteries as soon as possible. (wil l fl ash for 1 0 seconds then the meter will turn off) Dead batteries Replace the batteries.
Help 16 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk WHA T YOU SEE WH A T IT MEA NS WHA T YOU SHOULD DO E7 Wr ong test strip Remo ve the tes t st rip and re tes t us ing Asc ens ia M ICR OFI LL T est Str ip. If you cont inu e to ha ve p ro ble ms, cont act Bay er Cust ome r Serv ice .
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Help 17 www .ascensia.co.uk WHA T YOU SEE WH A T IT MEA NS WHA T YOU SHOULD DO Control test result is out-of- range (too high or too low). • T est strip or control solution is past the expiry date or is past the discard date.
Help 18 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Control Solution T esting: Con tro l Sol utio n T est in g Use Ascensia M ICROFILL Control Solutions to practice on the sys- tem or to run a check to make sure the meter and the test strips are working properly .
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Help 19 www .ascensia.co.uk Con tro l Sol utio n T est in g Gently rock the control bottle before opening to ensure it i s mixed well. Squeeze a small drop of control solution on a clean nonabsorbent surface (such as a piece of wax paper).
Help 20 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Compare your contr ol test result with the Normal Control Range printed on the test strip bottle label or on the bottom of the test strip box. NOTE: Low and High control range values can be found on the bottom of the test strip box.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 21 www .ascensia.co.uk Setting the Date, Time, and Sound: Y ou ca n se t yo ur meter to dis pla y differ ent options. T o get into set-up mode, press and hold M for three seconds. A complete display will briefly appear , then go to a display with the time.
Options 22 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Th e da te wil l n ow a pp ear on t he di spl ay . The year wi ll be fl as hin g. Pr ess ▲ or ▼ to r ea ch the cu rr ent year . Press M to set. The month will now fl ash.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 23 www .ascensia.co.uk 24H wi ll now fl ash on the dis pla y . Press ▲ or ▼ to choose the 12H or 24H setting. Thi s option let s you se t the met er to display time as a 12 hour setting with AM and PM or as a 24 hour display (military time).
Options 24 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Set tin g the Marke rs and Alar m: Markers and Alarm: Y ou will now see three markers displayed on your meter along with the word “ ”. Y o ur As ce ns ia C O N T O U R M et er c a n give you the option of marking your test results.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 25 www .ascensia.co.uk Using the Markers and Alarm Using the Markers and Alarm: If you have set your meter with the marker option on (see pages 21 –2 4 ), yo ur m e t er wi ll display three markers next to your blood glucose test result.
Options 26 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Press M or r emove the used test strip to automatically save the test result in the meter memory . OR Press ▲ or ▼ until all three markers disappear fr om the display .
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 27 www .ascensia.co.uk Using the Markers and Alarm Wh en the alar m s ou nd s, the me ter wi ll autom ati - cal ly turn on , t he alarm wi ll sou nd 20 tim es, and th e dis pl ay wi ll sh ow th e pre-meal test result you m a r k e d wh en yo u s e t th e alarm.
Options 28 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk TO MARK RESUL TS YO U WI LL S EE TO SET YOU WILL SEE WHA T IT MEANS Pre-Meal Press ▲ or ▼ ON Press M Result is marked as a pre-meal test. Y ou can now set an alarm.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 29 www .ascensia.co.uk TO MARK RESUL TS YO U WI LL S EE TO SET YOU WILL SEE WHA T IT MEANS Pre-Meal Press ▲ or ▼ ON Press M Result is marked as a pre-meal test. Y ou can now set an alarm.
Options 30 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) www .ascensia.co.uk Using the Memory: With the meter off, press the M b u t t o n o n t he me te r t o v ie w s to re d test results. The 14 day average will appear on the display with the average for test results taken over the last 14 days.
Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Options 31 www .ascensia.co.uk Press ▼ to review pr evious results. Previous results: Results will be shown starti ng wit h t he most recent. Each r esult will show the dat e and tim e the test was take n as wel l as any symb ols you chos e to mark the test result.
Extras 32 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Changing the Batteries: Bat ter ies shou ld be rep lac ed when the meter continually displays or the meter briefl y shows and the n turns of f (See Error Codes and Symbols, page 15).
Extras 33 www .ascensia.co.uk Caring for the System • Store meter in the carrying case provided whenever possible. • W ash hands and dry thoroughly before handling to keep the meter and test strips free of oils and other contaminants. • Handle the meter carefully to avoid damaging the electronics or causing other malfunctions.
Extras 34 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) IMPORT ANT : The Ascensia C ONTOUR Meter has not been tested or certified by Bayer for use with any so ftw are ot her th an t he Ba yer d ia bet es m an age men t so ftw are . Ba yer is n ot re sp ons ibl e f or an y err one ous re sul ts fro m t he use of ot her so f tw are .
Extras 35 www .ascensia.co.uk Accuracy T h e ac cu ra cy o f th e A sc e n s i a C O N T O U R Bl oo d G l u c o s e M o n i t o r - i n g S ys te m h as be en a s s e s s e d i n a c or re la ti on st ud y c o n d u c t e d b y he al t h c a re p r o f e s s i o n a l s.
Extras 36 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Specifi cations: T est Sample: Whole blood T est Result: Referenced to plasma/serum glucose Sample V olume: 0.
Extras 37 www .ascensia.co.uk The following symbols are used throughout the product labeling for the Ascensia ® C ONTOUR ® Blood Glucose Monitoring System (meter packaging and labeling, test strip packaging and labeling and contr ol solution packaging and labeling).
Extras 38 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Manufacturer’ s W arranty: Ba yer H ea l th Ca r e wa rr an ts to the original purchaser that this instrument will be free from defects in materials and workmanship for 5 years fr om the da te of or ig ina l p ur ch as e (ex cep t as no te d bel ow) .
Extras 39 www .ascensia.co.uk 4. Bayer HealthCare has no knowledge of the perform - ance of the Ascensia ® C ONTOUR ® Blood Glucose Met er when used with any test strips other than A sc e ns ia M IC.
Extras 40 Need Help? Call: 0845 600 6030 (UK)/1 890 920 111 (Ireland) Service Information: If you hav e a prob lem and none of the pr obl em sol vin g step s in the user guide help, call your Bayer Customer Service Representative. W e have trained specialists to help you.
Extras 41 www .ascensia.co.uk Supplies: When calling or writing for supplies be sure to include the number with the name of the replacement part or acces- sory item.
© 2006 Bayer HealthCare LLC N1146C Printed in UK Rev . 7/06 Bayer HealthCare LLC Subsidiary of Bayer Corporation Mishawaka, IN 46544 USA Bayer Diagnostics Europe Ltd. Chapel Lane, Swords, Co. Dublin, Ireland Ba yer , the Bayer Cross , Ascensia, C ONT OUR , M ICROFILL , M ICROLET and M ICR OLET V ACULANCE are trademarks of Ba yer .
Ein wichtiger Punkt beim Kauf des Geräts Bayer HealthCare Blood Glucose Meter (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bayer HealthCare Blood Glucose Meter noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bayer HealthCare Blood Glucose Meter - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bayer HealthCare Blood Glucose Meter reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bayer HealthCare Blood Glucose Meter erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bayer HealthCare Blood Glucose Meter besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bayer HealthCare Blood Glucose Meter verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bayer HealthCare Blood Glucose Meter. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bayer HealthCare Blood Glucose Meter gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.