Benutzeranleitung / Produktwartung MIU9.6FPD des Produzenten Telenetics
Zur Seite of 22
Document No. 49-0002-013 Rev. A Installation, Operation & Diagnostics for the MIU9.6FPD Industrial Grade, Digital Fast Poll Standalone Modem.
Document No. 49-0002-013 Rev. A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 1 TABLE OF CONTENTS 1. STANDARDS .... ............................................................................ .............. 2 2. PRODUCT OVERVIEW .. .......................
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 2 1. STANDARDS Meets FCC Rules Part J, Subpart 15 , Class A for radi at ed emissions.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 3 2. PR ODUCT OV ERVIEW The MIU9.6FPD is an industri al grade Digi tal Fast Poll m odem designed for multidropping appli cat ions over unconditioned me tallic l ines (eg; pilot wires).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 4 3. GENERAL PR ODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model : 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV” ): 9 to 36VDC Current Requirements : 12VDC 24VDC 125V DC 120VAC 220VAC MIU9.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 5 4. MODEM SPECIFICATIONS Modulation: Pulse Position Mo dulation ( PPM) Synch/Async: Asynchronous Only Data Rate: 0 – 1200bps Error Correction: None Data Compression: None Data Modulation Connectivity: Using 16m s Polli ng Test 99.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 6 Other Features Receiver Equali zation: Compromi se Equalizati on Self Test Diagnostics: None Local Analog Loopback: See Secti.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 7 5. METALLIC CONDUCTOR SP ECIFICATIONS The MIU9.6FPD contains di gital c irc ui try for connection 2 or 4-wire metal lic conductors (eg; pilot wires) . The M IU9.6FPD will also interface to Power Line Carrier or Mi crowa ve radio voice c hannel networks.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 8 6. POWER CONNECTIONS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 9 7. SERIAL DATA PORT PIN-OUTS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 10 8. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem t o vi ew dip switches as shown above Table 1 Switch Function ON OFF S.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 11 9. LED INDICATOR.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 12 10. OUTLINE DRAWING & MOUNTING.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 13 11. DIAGNOSTICS The following pages provide har dware techni ques for diagnosing comm unicati on problems and there by is olating the problem at the local mod e m, th e re mo t e mo d em o r the interconnecting line.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 14 Test 3: Received Signal Level Set Dip Switch 1 OFF (TxA = -10dBm ) and Dip Swit ch 3 OFF (RxA = -43dB m). CD will be ON. Run a test m essage a t TxD and verify that the sam e m essage is receive d at RxD with no data errors.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 15 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and re mote mo de ms a s f oll ow s: Swit.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 16 (d) LINE DIAGNOSTICS (i) Typical m odem configuration for 4-w ire Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Constant Carrier m ode).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 17.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 18.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 19.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 20 NOTES:.
Ein wichtiger Punkt beim Kauf des Geräts Telenetics MIU9.6FPD (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Telenetics MIU9.6FPD noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Telenetics MIU9.6FPD - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Telenetics MIU9.6FPD reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Telenetics MIU9.6FPD erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Telenetics MIU9.6FPD besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Telenetics MIU9.6FPD verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Telenetics MIU9.6FPD. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Telenetics MIU9.6FPD gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.