NEXUS Autopilot 1510 summary of known checkpoints All Autopilot systems are complex systems dependant of a number of transducers and control algorithms why faultfinding needs to be done carefully to lead to correct remedy. Checkpoints: Power: It is essential to Power the Pilot servo and the Pump motor to get current enough without risk of voltages drops. Wireing can be effective by using Relay to get shorter length of cables.

In a system without relay the Nexus system should never be powered up later than the AP Servo. To avoid ”backdrain” of current do not connect the Green wire (+12V) from the Nexus system.

Nexus 21 1510 diagram (page 1)
Abb. 1

Wire thickness dependant of Power Cable length :

Nexus 21 1510 diagram (page 1)
Abb. 2
Cable Length Max. m. (ft)Wire Area mm2Wire Area AWG 3 (10)2,514 5 (16)412 7,5 (25)610 12 (40)88

15A fuse

Page 2 of the Nexus 21 1510 user manual
Seite 2 · Zum Vergrößern klicken
Seite 2

Check dip switches:

Nexus 21 1510 diagram (page 2)
Abb. 3
Nexus 21 1510 diagram (page 2)
Abb. 4
Nexus 21 1510 diagram (page 2)
Abb. 5
Page 3 of the Nexus 21 1510 user manual
Seite 3 · Zum Vergrößern klicken
Seite 3

If a linear Rudder angle transmitter is used there should be two end- resistors, one on Black and one on Red wire from the RAT/RFU according to separate instruction, see Silva support: Autopilot Installation of the Linear rudder angle transmitter. Hydraulics: Check for Air in the system and bleed if needed (not valid for Silva HP 40 pumpset). Compass transducer: If the system has a Nexus Server, connect the Compass transducer to the Server for optimal function. Auto-deviation: Confirm that the Auto-deviation is good. In the Autopilot Manual § 5.5.5 you find the ”Auto CHK” , C4. Automatic Pilot Calibration ”APC”: Is the APC successfully performed in a speed close to the crushing speed of the boat? Autopilot set-up group ”P”. The APC will set the ”RUD”, ”SEA”, ”CRD”, ”ATC”, and ”RRS”. Be aware of those settings are not altered to unfavourable values. Remote Control: If a Nexus Remote Control is used in the system check that it is of Version 1.14 or higher to avoid risk for Err 25. Multi Center: The Autopilot button according to § 9 in Installation & Operation Manual for the Multi Center (P/N 21646-1) should be of momentary type, not a switch.

P ink W ire fr.

M u lticente r

Further investigations: If further investigations is needed, Note! Serial No. and Version No. on units.

Frage zu Nexus 21 1510 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.