Cordless Impact Driver Drill Akku-Schlagbohrschrauber Perceuse percussion/visseuse à batterie Trapano avvitatore a percussione a batteria Snoerloze klop-boor-schroefmachine Taladro atornillador de impacto a batería Berbequim aparafusador de impacto a bateria ∆ραπανκατσά ιδ µπαταρίας κρυστικ
DV 14DL • DV 18DL
Read through carefully and understand these instructions before use. Diese Anleitung vor Benutzung des Werkzeugs sorgfältig durchlesen und verstehen. Lire soigneusement et bien assimiler ces instructions avant usage. Prima dell’uso leggere attentamente e comprendere queste instruzioni. Deze gebruiksaanwijzing s.v.p. voor gebruik zorgvuldig doorlezen. Leer cuidadosamente y comprender estas instrucciones antes del uso. Antes de usar, leia com cuidado para assimilar estas instruções. ∆ιαάστε πρ σεκτικά και καταν ήσετε αυτές τις δηγίες πριν τη ρήση.
Handling instructions Bedienungsanleitung Mode d’emploi Istruzioni per l’uso Gebruiksaanwijzing Instrucciones de manejo Instruções de uso δηγίες ειρισµ ύ










d) Remove any adjusting key or wrench before
turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. e) Do not overreach. Keep proper footing and balance
at all times. This enables better control of the power tool in unexpected situations. f) Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts. g) If devices are provided for the connection of dust
SAVE THESE INSTRUCTIONS 1) Work area a) Keep work area clean and well lit.
Cluttered and dark areas invite accidents. b) Do not operate power tools in explosive
extraction and collection facilities, ensure these are connected and properly used. Use of these devices can reduce dust related hazards.
atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust of fumes. c) Keep children and bystanders away while operating
a power tool. Distractions can cause you to lose control.
power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. b) Do not use the power tool if the switch does not
turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired. c) Disconnect the plug from the power source before
Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. b) Avoid body contact with earthed or grounded
making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally. d) Store idle power tools out of the reach of children
surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded. c) Do not expose power tools to rain or wet
and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users. e) Maintain power tools. Check for misalignment or
conditions. Water entering a power tool will increase the risk of electric shock. d) Do not abuse the cord. Never use the cord for
binding of moving parts, breakage of parts and any other condition that may affect the power tools operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools. f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control. g) Use the power tool, accessories and tool bits etc.,
carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. e) When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
in accordance with these instructions and in the manner intended for the particular type of power tool, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from intended could result in a hazardous situation.
common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury. b) Use safety equipment. Always wear eye protection.
Safety equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. c) Avoid accidental starting. Ensure the switch is in
person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
the off position before plugging in. Carrying power tools with your finger on the switch or plugging in power tools that have the switch on invites accidents.
PRECAUTION Keep children and infirm persons away. When not in use, tools should be stored out of reach of children and infirm persons.

CAUTION ON LITHIUM-ION BATTERY
To extend the lifetime, the lithium-ion battery equips with the protection function to stop the output. In the cases of 1 and 2 described below, when using this product, even if you are pulling the switch, the motor may stop. This is not the trouble but the result of protection function. 1. When the battery power remaining runs out (The battery voltage drops to about 12V (DV18DL) / about 8V (DV14DL)), the motor stops. In such case, charge it up immediately. 2. If the tool is overloaded, the motor may stop. In this case, release the switch of tool and eliminate causes of overloading. After that, you can use it again.
1. Always charge the battery at a temperature of 0 – 50°C. A temperature of less than 0°C will result in over charging which is dangerous. The battery cannot be charged at a temperature higher than 50°C. The most suitable temperature for charging is that of 20 – 25°C. 2. When one charging is completed, leave the charger for about 15 minutes before the next charging of battery. Do not charge more than two batteries consecutively. 3. Do not allow foreign matter to enter the hole for connecting the rechargeable battery. 4. Never disassemble the rechargeable battery and charger. 5. Never short-circuit the rechargeable battery. Short- circuiting the battery will cause a great electric current and overheat. It results in burn or damage to the battery. 6. Do not dispose of the battery in fire. If the battery is burnt, it may explode. 7. When drilling in wall, floor or ceiling, check for buried electric power cord, etc. 8. Bring the battery to the shop from which it was purchased as soon as the post-charging battery life becomes too short for practical use. Do not dispose of the exhausted battery. 9. Using an exhausted battery will damage the charger. 10. Do not insert object into the air ventilation slots of the charger. Inserting metal objects or inflammables into the charger air ventilation slots will result in electrical shock hazard or damaged charger. 11. When mounting a bit into the keyless chuck, tighten the sleeve adequately. If the sleeve is not tight, the bit may slip or fall out, causing injury.

POWER TOOL
screws, tapping screws, etc. Drilling of various metals Drilling of various woods
Standard accessories are subject to change without notice.

Never short-circuit the battery. 2. Battery installation Insert the battery while observing its polarities (see Fig. 2).
not only recharging will become impossible, but it may also cause problems in the charger such as a deformed recharging terminal. 3. Charging When inserting a battery in the charger, charging will commence and the pilot lamp will light continuously in red. When the battery becomes fully recharged, the pilot lamp will blink in red (At 1-second intervals) (See Table 1). (1) Pilot lamp indication
Before using the impact driver drill, charge the battery as follows. 1. Connect the charger’s power cord to a receptacle When the power cord is connected, the charger’s pilot lamp will blink in red (At 1-second intervals).
The indications of the pilot lamp will be as shown in Table 1, according to the condition of the charger or the rechargeable battery.
(2) Regarding the temperatures of the rechargeable
(3) Regarding recharging time
battery The temperatures for rechargeable batteries are as shown in Table 2, and batteries that have become hot should be cooled for a while before being recharged.
Depending on the combination of the charger and batteries, the charging time will become as shown in Table 3.
Table 3 Charging time (At 20°C)
Table 2 Recharging ranges of batteries
The charging time may vary according to temperature and power source voltage.
Table 1

(2) When using this unit as a drill, align the cap drill mark
” with the triangle mark on the outer body. (3) When using this unit as an impact drill, align the cap
” with the triangle mark on the outer body. CAUTION The cap cannot be set between the numerals “1, 4, 7
After operation, pull out batteries from the charger first, and then keep the batteries properly.
Regarding electric discharge in case of new batteries, etc.
... 22” or the black dots. Do not use with the cap numeral between “22” and
the black line at the middle of the drill mark. Doing so may cause damage (See Fig. 5). 2. Tightening torque adjustment (1) Tightening torque
As the internal chemical substance of new batteries and batteries that have not been used for an extended period is not activated, the electric discharge might be low when using them the first and second time. This is a temporary phenomenon, and normal time required for recharging will be restored by recharging the batteries 2 – 3 times.
Tightening torque should correspond in its intensity to the screw diameter. When too strong torque is used, the screw head may be broken or be injured. Be sure to adjust the cap position according to the screw diameter. (2) Tightening torque indication
How to make the batteries perform longer.
The tightening torque differs depending on the type of screw and the material being tightened. The unit indicates the tightening torque with the numbers “1, 4, 7 ... 22” on the cap, and the black dots. The tightening toque at position “1” is the weakest and the torque is strongest at the highest number (See Fig. 4). (3) Adjusting the tightening torque
(1) Recharge the batteries before they become completely
exhausted. When you feel that the power of the tool becomes weaker, stop using the tool and recharge its battery. If you continue to use the tool and exhaust the electric current, the battery may be damaged and its life will become shorter. (2) Avoid recharging at high temperatures.
Rotate the cap and line up the numbers “1, 4, 7 ... 22” on the cap, or the black dots, with the triangle mark on the outer body. Adjust the cap in the weak or the strong torque direction according to the torque you need. CAUTION The motor rotation may be locked to cease while the
A rechargeable battery will be hot immediately after use. If such a battery is recharged immediately after use, its internal chemical substance will deteriorate, and the battery life will be shortened. Leave the battery and recharge it after it has cooled for a while. CAUTION When the battery charger has been continuosly used,
unit is used as drill. While operating the impact driver drill, take care not to lock the motor. Too long hammering may cause the screw broken
the battery charger will be heated, thus constituting the cause of the failures. Once the charging has been completed, give 15 minutes rest until the next charging. If the battery is recharged when it is warm due to
due to excessive tightening. 3. Rotation to Impact changeover (See Fig. 4) The “Rotation (Rotation only)” and “Impact (Impact + Rotation)” can be switched by aligning the drill mark “
battery use or exposure to sunlight, the pilot lamp map light in green. The battery will not be recharged. In such a case, let the battery cool before charging. When the pilot lamp flickers in red (at 0.2-second
” with the triangle mark on the outer body. To make holes in the metal, wood or plastic, switch
” or the hammer mark “
to “Rotation (Rotation only)”. To make holes in bricks or concrete blocks, switch to
intervals), check for and take out any foreign objects in the charger’s battery installation hole. If there are no foreign objects, it is probable that the battery or charger is malfunctioning. Take it to your authorized Service Center.
“Impact (Impact + Rotation)”. CAUTION
If an operation which is normally performed at the “Rotation” setting is performed at “Impact “ setting, the effect of making holes does not only increase but it may also damage the bit or other parts. 4. Change rotation speed By making a combination of the switch-over of “HIGH” or “LOW” with the shift knob and the switch-over of Power mode (P) or Save mode (S) with the lever on the side of the handle, the rotational speed can be set to four (4) steps. (See “SPECIFICATIONS”.) How to switch over “HIGH” or “LOW”
Operate the shift knob to change the rotational speed. Move the shift knob in the direction of the arrow (see Figs. 6 and 7). When the shift knob is set to “LOW”, the drill rotates at a low speed. When set to “HIGH”, the drill rotates at a high speed.
of the numbers “1, 4, 7 ... 22” on the cap, or the black dots, with the triangle mark on the outer body.
“ · hammer mark “

How to switch over the Power mode (P) or Save
If the motor is locked, immediately turn the power
mode (S) To set to the Power mode (P), slide the lever on the side of handle to the lower side, and to set to the Save mode (S), slide the lever to the upper side. (Fig. 8) CAUTION When changing the rotational speed with the shift
off. If the motor is locked for a while, the motor or battery may be burnt. In the work of the save mode (S), avoid the continuous
screw-tightening as temperature of electronic components of the converter switch increases. To extend the lifetime, the lithium-ion battery equips
knob, confirm that the switch is off. Changing the speed while the motor is rotating will damage the gears. When setting the shift knob to “HIGH” (high speed)
with the protection function to stop the output. Therefore, if the tool is overloaded, the motor may stop. However, this is not the trouble but the result of protection function. In this case, release the switch of tool and eliminate the causes of overloading. 5. The scope and suggestions for uses The usable scope for various types of work based on the mechanical structure of this unit is shown in Table 4.
and the position of the cap is bitween “16” and “22”, it may happen that the clutch does not engaged and that the motor is locked. In such a case, please set the shift knob to “LOW” (low speed).
The use of the battery BCL1430, EBL1430, EBM1430 and EBM1830 in a cold condition (below 0 degree Centigrade) can sometimes result in the weakened tightening torque and reduced amount of work. This, however, is a temporary phenomenon, and returns to normal when the battery warms up.
considered as general standard. As different types of tightening screws and different materials to be tightened are used in actual works proper adjustments are naturally necessary. When using the impact driver drill with a machine
screw at HIGH (high speed), a screw may damage or a bit may loose due to the tightning torque is too strong. Use the impact driver drill at LOW (low speed) when using a machine screw.
Table 4

Injury may result if you carry the equipment suspended from the waist belt with sharp tipped components such as drill bit attached.
Loosen the sleeve by turning it toward the left (in the counterclockwise direction as viewed from the front) to open the clip on the keyless chuck. After inserting a driver bit, etc., into the keyless drill chuck, and tighten the sleeve by turning it toward the right (in the clockwise direction as viewed from the front) (See Fig. 9). If the sleeve becomes loose during operation, tighten
The hook can be installed on the right or left side and the angle can be adjusted in 5 steps between 0° and 80°. (1) Operating the hook
(a) Pull out the hook toward you in the direction of
arrow (A) and turn in the direction of arrow (B) (Fig. 11). (b) The angle can be adjusted in 5 steps (0°, 20°, 40°,
it further. The tightening force becomes stronger when the sleeve is tightened additionally. (2) Dismounting the bit
60°, 80°). Adjust the angle of the hook to the desired position for use. (2) Switching the hook position CAUTION
Loosen the sleeve by turning it toward the left (in the counterclockwise direction as viewed from the front), and then take out the bit, etc. (See Fig. 9). NOTE
Incomplete installation of the hook may result in bodily injury when used. (a) Securely hold the main unit and remove the screw
If the sleeve is tightened in a state where the clip of the keyless chuck is opened to a maximum limit, a click noise may occur. This is the noise that occurs when the loosening of the keyless chuck is prevented and is not a malfunction. CAUTION When it is no longer possible to loosen the sleeve,
using a slotted head screwdriver or a coin (Fig. 12). (b) Remove the hook and spring (Fig. 13). (c) Install the hook and spring on the other side and
securely fasten with screw (Fig. 14). NOTE
Pay attention to the spring orientation. Install the spring with larger diameter away from you (Fig. 14). (3) Using the bit holder (Hook with bit holder)
use a vise or similar instrument to secure the bit. Set the clutch mode between 1 and 7 and then turn the sleeve to the loose side (left side) while operating the clutch. It should be easy now to loosen the sleeve. 8. Automatic spindle-lock mechanism This unit has automatic spindle-lock mechanism for quick bit changes. 9. Confirm that the battery is mounted correctly 10. Check the rotational direction The bit rotates clockwise (viewed from the rear side) by pushing the R-side of the selector button. The L-side of the selector button is pushed to turn the bit counterclockwise (See Fig. 10). (The L and R marks are provided on the selector button.) CAUTION Always use this unit with clockwise rotation, when
Installing the bit
Slide the bit from the side, and then insert firmly until the groove on the bit locks in the protruded section of the hook. Removing the bit
Securely hold the main unit and pull out the bit by holding the tip with your thumb (Fig. 15). CAUTION Only Hitachi STANDARD ACCESSORIES phillips bit
(No. 2 × 65L; Code No. 983006) may be used. Do not use other bits since they may come loose. (4) Using as an auxiliary light (Hook with light)
(a) Press the switch to turn off the light.
If forgotten, the light will turn off automatically after 15 minutes. (b) The direction of the light can be adjusted within
using it as an impact drill. 11. Switch operation When the trigger switch is depressed, the tool rotates.
the range of hook positions 1 - 5 (Fig. 16). Lighting time
When the trigger is released, the tool stops. The rotational speed of the drill can be controlled by
varying the amount that the trigger switch is pulled. Speed is low when the trigger switch is pulled slightly and increases as the trigger switch is pulled more. NOTE A buzzing noise is produced when the motor is about
Do not look directly into the light. Such actions could result in eye injury. (5) Replacing the batteries (Hook with light)
to rotate. This is only a noise, not a machine failure. 12. For drilling into brick Excessive pressing force never increases drilling speed. It will not only damage the drill tip or reduce working efficiency, but could also shorten the service life of drill bit. Operate the impact driver drill within 10-15 kg pressing force while drilling into brick. 13. Using the hook CAUTION When using the hook, pay sufficient attention so that
(a) Loosen the hook screw with a phillips-head
screwdriver (No. 1) (Fig. 17). Remove the hook cover by pushing in the direction of the arrow (Fig. 18). (b) Remove the old batteries and insert the new
batteries. Align with the hook indications and position the plus (+) and minus (–) terminals correctly (Fig. 19). (c) Align the indentation in the hook main body with
the protuberance of the hook cover, press the hook cover in the direction opposite to that of the arrow shown in Fig. 18 and then tighten the screw. Use commercially available AAAA batteries (1.5 V).
the main equipment does not fall. If the tool falls, there is a risk of accident. Do not attach the tip tool except phillips bit to the tool
main unit when carrying the tool main unit with the hook suspended from a waist belt.

NOTE
Do not tighten the screw excessively. Such action could strip the screw threads. CAUTION Failure to observe the following can result in battery
When replacing the carbon brush with a new one, be sure to use the Hitachi Carbon Brush Code No. 999054. 5. Replacing carbon brushes Take out the carbon brush by first removing the brush cap and then hooking the protrusion of the carbon brush with a flat head screw driver, etc., as shown in Fig. 25. When installing the carbon brush, choose the direction so that the nail of the carbon brush agrees with the contact portion outside the brush tube. Then push it in with a finger as illustrated in Fig. 26. Lastly, install the brush cap. CAUTION
leakage, rust or malfunction. Position the plus (+) and minus (–) terminals correctly. Replace both batteries at the same time. Do not mix old and new batteries. Remove exhausted batteries from the hook immediately. Do not discard batteries together with normal trash
and do not throw batteries into fire. Store batteries out of the reach of children. Use batteries correctly in accordance with the battery
Be absolutely sure to insert the nail of the carbon brush into the contact portion outside the brush tube. (You can insert whichever one of the two nails provided.) Caution must be exercised since any error in this operation can result in the deformed nail of the carbon brush and may cause motor trouble at an early stage. 6. Cleaning on the outside When the Impact driver drill is stained, wipe with a soft dry cloth or a cloth moistened with soapy water. Do not use chloric solvents, gasoline or paint thinner, for they melt plastics. 7. Storage Store the Impact driver drill in a place in which the temperature is less than 40°C and out of reach of children. 8. Service parts list CAUTION
specifications and indications. 14. Using the bit holder CAUTION Stow the bit in the specified location on the tool. If
the tool is used with the bit stowed improperly, the bit may fall and cause bodily injury. Do not stow bits that are of a different length, gauge
or dimension than the plus driver bit (65 mm long) included in the STANDARD ACCESSORIES. The bit may fall and cause bodily injury. (1) Removing the bit
Securely hold the main unit and pull out the bit by holding the tip with your thumb (Fig. 20). (2) Installing the Bit
Install the bit with steps opposite of when removing. Insert the bit so that the right and left sides are equal, as shown in Fig. 21. 15. Installing/Removing the side handle CAUTION Firmly install the side handle. If loose, the side handle
Repair, modification and inspection of Hitachi Power Tools must be carried out by a Hitachi Authorized Service Center. This Parts List will be helpful if presented with the tool to the Hitachi Authorized Service Center when requesting repair or other maintenance. In the operation and maintenance of power tools, the safety regulations and standards prescribed in each country must be observed. MODIFICATIONS
may gyrate or fall out and cause bodily injury. (1) Install the side handle so that the protrusions on the
main unit and grooves on the side handle interlock. Tighten the grip after checking that the side handle is not riding on the slip prevention protrusion (Fig. 22). (2) Loosen the grip to remove the side handle.
Hitachi Power Tools are constantly being improved and modified to incorporate the latest technological advancements. Accordingly, some parts may be changed without prior notice.
1. Inspecting the tool Since use of as dull tool will degrade efficiency and cause possible motor malfunction, sharpen or replace the tool as soon as abrasion is noted. 2. Inspecting the mounting screws Regularly inspect all mounting screws and ensure that they are properly tightened. Should any of the screws be loose, retighten them immediately. Failure to do so could result in serious hazard. 3. Maintenance of the motor The motor unit winding is the very “heart” of the power tool. Exercise due care to ensure the winding does not become damaged and/or wet with oil or water. 4. Inspecting the carbon brushes (Fig. 23) The motor employs carbon brushes which are consumable parts. Since and excessively worn carbon brush can result in motor trouble, replace the carbon brush with new ones when it becomes worn to or near the “wear limit”. In addition, always keep carbon brushes clean and ensure that they slide freely within the brush holders.
We guarantee Hitachi Power Tools in accordance with statutory/country specific regulation. This guarantee does not cover defects or damage due to misuse, abuse, or normal wear and tear. In case of complaint, please send the Power Tool, undismantled, with the GUARANTEE CERTIFICATE found at the end of this Handling instruction, to a Hitachi Authorized Service Center.

Blue: – Neutral Brown: – Live As the colours of the wires in the mains lead of this tool may not correspond with the coloured markings identifying the terminals in your plug proceed as follows: The wire coloured blue must be connected to the terminal marked with the letter N or coloured black. The wire coloured brown must be connected to the terminal marked with the letter L or coloured red. Neither core must be connected to the earth terminal. NOTE This requirement is provided according to BRITISH STANDARD 2769: 1984. Therefore, the letter code and colour code may not be applicable to other markets except United Kingdom.
Information concerning airborne noise and vibration The measured values were determined according to EN 60745 and declared in accordance with ISO 4871.
DV14DL Measured A-weighted sound power level: 93 dB(A) Measured A-weighted sound pressure level: 82 dB(A) Uncertainty KpA: 3 dB(A)
The typical weighted root mean square acceleration value: 7.6 m/s2.
DV18DL Measured A-weighted sound power level: 93 dB(A) Measured A-weighted sound pressure level: 82 dB(A) Uncertainty KpA: 3 dB(A)
The typical weighted root mean square acceleration value: 9.5 m/s2.
Wear ear protection.