Panasonic Air Conditioner (S-36PN1E5A)

56 Seiten·2 MB·HLK-Technik·PDF·ENJA
Panasonic Air Conditioner (S-36PN1E5A)
Inhaltsverzeichnis 37 Abschnitte Operating Instructions Air Conditioner · Ducted (N1 type) · INDOOR UNIT · Ducted Type S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A · … AnzeigenAusblenden
Page 1 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — — U-100PEY1E8 U-125PEY1E8 U-140PEY1E8
Seite 1 · Zum Vergrößern klicken
Seite 1

Operating Instructions Air Conditioner

Ducted (N1 type)

Model No.

INDOOR UNIT

Ducted Type S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A

ENGLISH 2 ~ 7 Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5A

FRANÇAIS 8 ~ 13 Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.

F RANÇAIS

OUTDOOR UNIT

Single Split (Single-phase) PE1 Type — — U-50PE1E5 U-60PE1E5A

ESPAÑOL 14 ~ 19 Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.

E SPAÑOL

U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A Single Split (3-phase) PE1 Type —

DEUTSCH 20 ~ 25 Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.

D EUTSCH

ITALIANO 26 ~ 31 Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.

I TALIANO

U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A Single Split (Single-phase) PEY1 Type — — — U-60PEY1E5

NEDERLANDS 32 ~ 37 Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en bewaar ze voor toekomstig gebruik.

N EDERLANDS

PORTUGUÊS 38 ~ 43 Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.

U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 — Single Split (3-phase) PEY1 Type —

P ORTUGUÊS

EΛΛΗΝΙΚΆ 44 ~ 49 Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και διατηρήστε τις για μελλοντική αναφορά.

E ΛΛΗΝΙΚΆ

БЪЛГАРСКИ 50 ~ 55 Преди да започнете експлоатация на този уред, прочетете внимателно тези инструкции и ги запазете, за да можете да правите справки с тях и в бъдеще.

— U-100PEY1E8 U-125PEY1E8 U-140PEY1E8

Б ЪЛГАРСКИ

Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan P07-T11610A

Page 3 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — Important Information Regarding The Refrigerant Used
Seite 3 · Zum Vergrößern klicken
Seite 3
Panasonic Air Conditioner (S-36PN1E5A) — NOTICE diagram (page 3)
Abb. 1

This appliance is intended to be used by expert or trained users in shops,in light industry and on farms, or for commercial use by lay persons. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Keep the fi re alarm and the air outlet at least 1.5m away from the unit. Do not cool or heat the room too much if babies or invalids are present. Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. Do not touch the air inlet or the sharp aluminum fi ns of the outdoor unit. You may get injured. Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.

Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, circuit breaker and earth leakage breaker for overcurrent protection should be provided in the exclusive line. Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fi xed wiring in accordance with the wiring rules. To prevent possible hazards from insulation failure, the unit must be grounded. Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.

  • Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure:
  • The ELCB trips frequently.
  • The product sometimes does not start when turned on.
  • The power is sometimes disconnected when the cord is moved.
  • Burnt odor or abnormal noise is detected during operation.
  • The body is deformed or abnormally hot.
  • Water leaks from the indoor unit.
  • Power cord or plug becomes abnormally hot.
  • Fan speed cannot be controlled.
  • The unit stops running immediately even if it is switched on for operation.
  • The fan does not stop even if the operation is stopped. Contact immediately your local dealer for maintenance/repair.

NOTICE

  • The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
  • The English text is the original instructions. Other languages are translation of the original instructions.

Important Information Regarding The Refrigerant Used

This product contains fl uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A GWP

(1) value1975

(1) GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.

Do not sit or step on the unit. You may fall down accidentally.

Page 4 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — NOTE
Seite 4 · Zum Vergrößern klicken
Seite 4

Precautions for Use

Installation

Operation Condition

z This air conditioner must be installed properly by qualifi ed

Use this air conditioner under the following temperature range.

installation technicians in accordance with the Installation Instructions provided with the unit. z Before installation, check that the voltage of the electric sup-

„Indoor temperature range: Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT) Heating mode 16°C ~ 30°C (*DBT)

ply in your home or offi ce is the same as the voltage shown on the nameplate.

„Outdoor temperature range: Cooling mode -15°C ~ 46°C (*DBT) -10°C ~ 43°C (*DBT)*1 Heating mode -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT) -15°C ~ 18°C (*WBT) / -15°C ~ 24°C (*DBT)*1

WARNING

Avoid the following locations for installation.

z Locations where smoke or combustible gas exists.

*DBT: Dry bulb temperature *WBT: Wet bulb temperature *1 When connecting U-60PEY1E5, U-71PEY1E5, U-100PEY1E5, U-100PEY1E8, U-125PEY1E5, U-125PEY1E8, U-140PEY1E8

Also locations of extremely high temperature such as a greenhouse. z Locations where excessively high heat-generating ob-

jects are placed.

Attention:

Information for Users on Collection and Disposal of Old Equipment and Used Batteries

z Avoid installing the outdoor unit where salty sea water can

splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)

These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

Wiring

z All wiring must conform to the local electrical codes.

(Consult your dealer or a qualifi ed electrician for details.) z Each unit must be properly grounded with a ground (or

earth) wire or through the supply wiring. z Wiring must be done by a qualifi ed electrician.

Operation Preparation

Turn the power mains on 5 hours before the start of operation. (For warm-up)

ON

z Leave the power mains ON for continuous use.

NOTE

Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.

For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.

[Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.

Pb

Page 5 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — Operation Mechanism
Seite 5 · Zum Vergrößern klicken
Seite 5

Names of Parts

Panasonic Air Conditioner (S-36PN1E5A) — Names of Parts diagram (page 5)
Abb. 2 · Names of Parts

Air outlet PE1 (50 type) PE1 (60, 71 type) PE1 (100, 125, 140 type) PEY1 (60, 71 type) PEY1 (100, 125 type) PEY1 (140 type)

Panasonic Air Conditioner (S-36PN1E5A) — Names of Parts diagram (page 5)
Abb. 3 · Names of Parts

Operation Mechanism

z Since this air conditioner utilizes outside air for heating,

z Once the room temperature reaches the level that was

its heating performance deteriorates as outside tempera- ture decreases. (Due to heat pump system) →In that case, use another heating appliance. „Defrosting

set, the outdoor unit repeats the cycle of turning on and off automatically. z When the outdoor unit is turned off, the indoor unit fan

will stop, too. (To prevent the humidity in the room from rising again) z When the room temperature is more likely to reach the

z This appliance may start defrosting operation to melt

level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. z ‘‘DRY’’ operation is not possible if the outdoor tempera-

frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). →” ” (STANDBY) appears. 2Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up suffi ciently. → ” ” (STANDBY) is shown. 3 Defrosting is complete: The indoor unit fan starts operation. → ” ” (STANDBY) disappears.

ture is 15 °C or less. „Should the power failure occurs while the

unit is running When the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off.

„Heating performance · „‘‘DRY’’ operation

Page 6 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — Before Requesting Services
Seite 6 · Zum Vergrößern klicken
Seite 6

Maintenance

WARNING

Tips for Energy Saving

z For safety, be sure to turn the air conditioner off and dis-

z Do not block the air intake and outlet of the unit.

connect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.) z Do not pour water on the indoor unit.

(If either is obstructed, the unit will not function well, causing malfunction.) z During cooling operation, use sunshades, blinds or cur-

(This may damage the internal components and cause an electric shock hazard.)

tains to prevent direct sunlight from entering the room.

z Always keep the air fi lter clean.

(A clogged fi lter will impair the performance of the unit.) → “Maintenance” z To prevent conditioned air from escaping, keep win-

CAUTION

dows, doors and any other openings closed.

z Never use solvents or harsh chemicals. Also, do not wipe

plastic parts using very hot water. (This may cause deformation or change in colour.) z Some metal edges and fi ns are sharp. Be careful when

you clean those parts. (Injury may result.) z Use a fi rm stool or ladder when cleaning an indoor unit

installed in high locations.

z The internal coil and other components of the outdoor unit

must be cleaned periodically. • Consult your dealer or service center.

Before Requesting Services

SymptomCauseAction The air conditioner does not operate although the power is turned on.Power failure or after power failure.Press the power ON/OFF button on the remote controller. The operation (power) button is turned off.• If the breaker is turned off, turn the power on. • If the breaker has been tripped, consult your dealer without turning it on. Fuse blow out.Contact your dealer. Poor cooling or heating performanceThe air intake or air outlet of indoor and outdoor units is clogged with dust.Remove the dust. The wind speed switch is set to “Low”.Change to “High” or “Strong”. Improper temperature settings.See “Tips for Energy Saving”. The room is exposed to direct sunlight in cooling mode. Doors or windows are open. The air fi lter is clogged.See “Maintenance”. Too many heat sources in the room in cooling mode.Use minimum heat sources and in a short time. Too many people in the room in cooling mode.Lower the temperature setting or change to “High” or “Strong”.

If your air conditioner does not work properly even after checking each item of “Before Requesting Services” and “Troubleshooting”

z Stop the operation immediately and turn the power off. Then contact your dealer and report the serial number and symptom.

You also report if the inspection mark and the letters E, F, H, L, P in combination with numbers appear on the LCD of the remote controller. z Never repair the air conditioner by yourself since it is very dangerous for you to do so.

„Avoid · „Do

Page 7 of the Panasonic Air Conditioner (S-36PN1E5A) user manual — Outdoor unit
Seite 7 · Zum Vergrößern klicken
Seite 7

Troubleshooting

Check before consulting or requesting services.

Symptom Cause / Action

NoiseSound like streaming water is heard during operation or after operation. Cracking noise is heard during operation or when operation stops. Discharged air smells during operation. Dewdrops accumulate near the air outlet during cooling operation. Fog occurs during cooling operation. Fog occurs during heating operation. The fan is rotating for a while even though operation stops. Dust is discharged. At the initial high-speed operation, the fan sometimes rotates faster than the setting speed. (3 to 30 minutes)
  • Sound of refrigerant liquid fl owing inside unit.
  • Sound of drainage water through drain pipe.
  • Indoor odor components, cigarette odor and cosmetic odor accumulated in the air conditioner and its air is discharged.
  • The unit inside is dirty. (Contact your dealer.)
  • Internal moisture is cooled by cool wind and accumulates as dewdrops.
  • If the air conditioner has been installed at places such as restaurants where large amounts of oil mist exist, cleaning is necessary because the unit inside (heat exchanger) is dirty. (Contact your dealer.)

Indoor unit

  • Fan rotation makes operation smooth.
  • The fan may rotate to dry the heat exchanger depending on the setting.
  • This is for operation check in order to confi rm whether the fan motor rotation is within the range of use.

No operation (When the power is turned on immediately / When operation is stopped and resumed immediately)

  • Operation is not activated for the fi rst approx. 3 minutes because the compressor protection circuit is activated.

Outdoor unit

Noise occurs during heating operation.

  • Defrost operation is in process. Steam comes out during heating operation.

The fan continues to rotate even after the operation is stopped using the remote controller.

  • This is for smooth operation.
Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
The air conditioner does not operate although the power is turned on.Power failure or after power failure.Press the power ON/OFF button on the remote controller. p.6
The air conditioner does not operate although the power is turned on.The operation (power) button is turned off.• If the breaker is turned off, turn the power on. • If the breaker has been tripped, consult your dealer without turning it on. p.6
The air conditioner does not operate although the power is turned on.Fuse blow out.Contact your dealer. p.6
Poor cooling or heating performanceThe air intake or air outlet of indoor and outdoor units is clogged with dust.Remove the dust. p.6
Poor cooling or heating performanceThe wind speed switch is set to “Low”.Change to “High” or “Strong”. p.6
Poor cooling or heating performanceImproper temperature settings.See “Tips for Energy Saving”. p.6
Poor cooling or heating performanceThe room is exposed to direct sunlight in cooling mode. p.6
Poor cooling or heating performanceDoors or windows are open. p.6
Poor cooling or heating performanceThe air fi lter is clogged.See “Maintenance”. p.6
Poor cooling or heating performanceToo many heat sources in the room in cooling mode.Use minimum heat sources and in a short time. p.6
Poor cooling or heating performanceToo many people in the room in cooling mode.Lower the temperature setting or change to “High” or “Strong”. p.6

Frage zu Panasonic Air Conditioner (S-36PN1E5A) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Panasonic Air Conditioner (S-36PN1E5A)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Panasonic Air Conditioner (S-36PN1E5A) PDF-Anleitung

56 Seiten·2 MB·HLK-Technik·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…