Read and follow the operating and safety instructions before you start working with this power tool.
Wear ear-muffs. The impact of noise can cause damage to hearing.
Do not expose the machine to rain. The device may only be stationed, stored and operated in dry ambient conditions.



The machine can only be operated by persons who were instructed concerning the operation of the machine and who are informed about the associated dangers. The minimum age requirement must be complied with. In addition to the safety notices contained in this op- erating manual and the particular instructions for your country, the generally recognised technical regulations for the operation of identical devices must be complied with. We accept no liability for damage or accidents which arise due to non-observance of these instructions and the safety information.
Manufacturer:
Scheppach GmbH Günzburger Straße 69 D-89335 Ichenhausen
Dear Customer, we hope your new tool brings you much enjoyment and success.
We recommend: Read through the complete text in the operating in- structions before installing and commissioning the device. The operating instructions are intended to help the user to become familiar with the machine and take advan- tage of its application possibilities in accordance with the recommendations. The operating instructions contain important informa- tion on how to operate the machine safely, profession- ally and economically, how to avoid danger, costly re- pairs, reduce downtimes and how to increase reliability and service life of the machine. In addition to the safety regulations in the operating instructions, you have to meet the applicable regula- tions that apply for the operation of the machine in your country. Keep the operating instructions package with the machine at all times and store it in a plastic cover to protect it from dirt and moisture. Read the instruction manual each time before operating the machine and carefully follow its information.
The compressor is designed to generate compressed air for compressed-air driven tools which can be driven with an air volume of up to approx. 89 l/min (e.g. tire inflator, blow-out pistol and paint spray gun).

The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of mis- use. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
– They work better and more safely in the spec- ified output range. 7. Wear suitable clothing
– Do not wear wide clothing or jewellery, which can become entangled in moving parts. – Rubber gloves and non-slip shoes are recom- mended when working outdoors. – Tie long hair back in a hair net. 8. Do not use the cable for purposes for which it is not intended
Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the equipment is used in commercial, trade or industrial businesses or for equivalent purposes.
– Do not use the cable to pull the plug out of the outlet. Protect the cable from heat, oil and sharp edges. 9. Take care of your tools
m Attention! The following basic safety measures must be observed when using electric tools for protec- tion against electric shock, and the risk of injury and fire. Read all these notices before using the electric tool and keep the safety instructions for later reference.
– Keep your compressor clean in order to work well and safely. – Follow the maintenance instructions. – Check the connection cable of the electric tool regularly and have it replaced by a recognised specialist when damaged. – Check extension cables regularly and replace them when damaged. 10. Pull the plug out of the outlet – During non-use of the electric tool or prior to maintenance and when replacing tools such as saw blades, bits, milling heads. 11. Avoid inadvertent starting
m Attention! The following basic safety actions must be taken when using this compressor in order to pro- tect the user from electric shocks and the risk of injury and fire. Read and follow these instructions before us- ing the equipment.
Safe work 1. Keep the work area orderly
– Make sure that the switch is switched off when plugging the plug into an outlet. 12. Use extension cables for outdoors – Only use approved and appropriately identi- fied extension cables for use outdoors. – Only use cable reels in the unrolled state. 13. Remain attentive – Pay attention to what you are doing. Remain sensible when working. Do not use the elec- tric tool when you are distracted. 14. Check the electric tool for potential damage – Protective devices and other parts must be carefully inspected to ensure that they are fault-free and function as intended prior to continued use of the electric tool. – Check whether the moving parts function faultlessly and do not jam or whether parts are damaged. All parts must be correctly mounted and all conditions must be fulfilled to ensure fault-free operation of the electric tool.
– Disorder in the work area can lead to acci- dents. 2. Take environmental influences into account
– Do not expose electric tools to rain. – Do not use electric tools in a damp or wet environment. There is a risk of electric shock! – Make sure that the work area is well-illumi- nated. – Do not use electric tools where there is a risk of fire or explosion. 3. Protect yourself from electric shock
– Avoid physical contact with earthed parts (e.g. pipes, radiators, electric ranges, cool- ing units). 4. Keep children away
– Do not allow other persons to touch the equipment or cable, keep them away from your work area. 5. Securely store unused electric tools
– Unused electric tools should be stored in a dry, elevated or closed location out of the reach of children.

– Damaged protective devices and parts must be properly repaired or replaced by a recog- nised workshop, insofar as nothing different is specified in the operating manual. – Damaged switches must be replaced at a customer service workshop. – Do not use any faulty or damaged connection cables. – Do not use any electric tool on which the switch cannot be switched on and off. 15. Have your electric tool repaired by a qualified electrician
m WARNING! This electric tool generates an elec- tromagnetic field during operation. This field can im- pair active or passive medical implants under certain conditions. In order to prevent the risk of serious or deadly injuries, we recommend that persons with medical implants consult with their physician and the manufacturer of the medical implant prior to operating the electric tool.
– This electric tool conforms to the applicable safety regulations. Repairs may only be per- formed by an electrician using original spare parts. Otherwise accidents can occur. 16. Important! – For your own safety you must only use the ac- cessories and additional units listed in the oper- ating instructions or recommended or specified by the manufacturer. The use of mounted tools or accessories other than those recommended in the operating instructions or catalogue may place your personal safety at risk. 17. Noise
– Wear ear muffs when you use the compressor. 18. Replacing the power cable – To prevent hazards, leave the replacement of damaged power cables strictly to the manu- facturer or a qualified electrician. There is a risk of electric shock! 19. Inflating tires – Directly after inflating tires, check the pres- sure with a suitable pressure gauge, for ex- ample at your filling station. 20. Roadworthy compressors for building site oper- ations
– Make sure that all lines and fittings are suit- able for the maximum permissible operating pressure of the compressor. 21. Place of installation – Set up the compressor on an even surface. 22. Supply hoses at pressures above 7 bar should be equipped with a safety cable (e.g. a wire rope). 23. Avoid over-stressing the piping system by using flexible hose connections to prevent kinking. 24. Use a residual current circuit breaker with a trigger current of 30 mA or less. Using a residual current circuit breaker reduces the risk of an electric shock.

Mains connection 230 V~ 50 Hz
Motor rating 750 W
Compressor speed 1400 min-1
Pressure vessel capacity 20 l
Operating pressure approx. 10 bar
Theoretical intake capacity approx. 200 l/min
Effective delivery quantity at 1 bar approx. 89 l/min
Weight of the unit approx. 30 kg
Max. altitude (above mean sea level) 1000 m
The noise emission values were measured in accord- ance with EN ISO 3744.
Wear hearing protection. The effects of noise can cause a loss of hearing.
m Warning: Noise can have serious effects on your health. If the machine noise exceeds 85 dB (A), please wear suitable hearing protection.
Do not lose these safety instructions
Sound power level LwA 80 dB(A)
Residual risks Comply with the stipulated maintenance and safety instructions in the operating instructions. Remain attentive at all times when working, and keep third parties at a safe distance from your work area.
Sound pressure level LpA 54 dB(A)
Uncertainty KwA/pA 3 dB
Even when the device is being used properly, there will always be certain residual hazards that cannot be completely ruled out. The following potential hazards can arise due to the type and design of the device: • Unintentional starting up of the product.
Operating mode S1 · Protection type IP20 · Protection class I

8.5 Setting the pressure switch (Fig. 1) • The pressure switch (14) is set at the factory. Cut in pressure approx. 8 Bar Cut-out pressure approx. 10 Bar.
m Important! You must fully assemble the appliance before using it for the first time!
8.1 Fitting the compressed air hose (fig. 2) • Connect the plug nipple of the compressed air hose (not included in the scope of delivery) to one of the quick couplings (13). Then attach the compressed air tool to the quick coupling of the compressed air hose.

Connections and repairs of electrical equipment may only be carried out by an electrician.
The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE and DIN provisions. The customer‘s mains connection as well as the extension cable used must also comply with these regulations.
When working with spray attachments and during tem- porary use outdoors, the device must be connected to a residual current circuit breaker with a trigger current of 30 mA or less.
m Important! Pull out the power plug before doing any cleaning and maintenance work on the equipment. Risk of injury from electric shock!
m Important! Wait until the equipment has cooled down completely! Risk of burns!
m Important! Always depressurize the equipment before carrying out any cleaning and maintenance work! Risk of injury!
10.2 Maintenance work on the pressure vessel (Fig. 1) Important! To ensure a long service life of the pressure vessel (2), drain off the condensed wa- ter by opening the drain valve (3) each time after using. Release the vessel pressure first (see 10.5.1). Open the drain screw by turning counter-clockwise (looking at the screw from the bottom of the compressor) so that all the condensed water can run out of the pres- sure vessel. Then close the drain screw again (turn it clockwise).
The printing of the type designation on the connection cable is mandatory.

Check the pressure vessel for signs of rust and dam- age each time before using. Do not use the compres- sor with a damaged or rusty pressure vessel. If you discover any damage, then please contact the custom- er service workshop.
10.5.1 Releasing excess pressure Release the excess pressure by switching off the com- pressor and using the compressed air which is still left in the pressure vessel, e.g. with a compressed air tool running in idle mode or with a blow-out pistol.
m Important! The condensed water from the pressure vessel will contain residual oil. Dispose of the condensed water in an environmentally compatible manner at a suitable collection point.
10.6 Service information Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consuma- bles. Wear parts*: belt, coupling
10.3 Safety valve (Fig. 2) The safety valve (9) has been set for the highest per- mitted pressure of the pressure vessel. It is not permit- ted to adjust the safety valve or remove the connection lock between the exhaust nut and its cap.
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our service centre. To do this, scan the QR code on the cover page.
Actuate the safety valve every 30 operating hours but at least 3 times a year, to ensure that it works when required. Turn the perforated drain nut anti-clockwise to open it. Now, the valve audibly releases air. Then, tighten the exhaust nut clockwise again.
Use the transport handle (1) to transport the device, and drive the compressor with it. The handle height can be adjusted on the height ad- justment (5), as shown in figure 5. The handle height can be adjusted from 53 cm up to 82.5 cm. When lifting the compressor, note its weight (see Technical data). Ensure that the load is well secured when transporting the compressor in a motor vehicle.
10.4 Cleaning the intake filter (Fig. 4) The intake filter prevents dust and dirt being drawn in. It is essential to clean this filter after at least every 300 hours in service. A clogged intake filter will decrease the compressor’s performance dramatically. Open the screw (18) to remove the intake filter.
Then pull off the filter cover (17). Now you can remove the air filter (16). Carefully tap out the air filter, filter cover and filter housing. Then blow out these parts with com- pressed air (approx. 3 bar) and reinstall in reverse order.
The packaging materials are recy-
clable. Please dispose of packag- ing in an environmentally friendly manner.
10.5 Storage m Important! Pull out the mains plug and ventilate the equip- ment and all connected pneumatic tools. Switch off the compressor and make sure that it is se- cured in such a way that it cannot be started up again by any unauthorized person.
m Important! Store the compressor only in a dry location which is not accessible to unauthorized persons. Always store upright, never tilted!

- Public disposal or collection points (e.g. municipal works yards) - Points of sale of electrical appliances (stationary and online), provided that dealers are obliged to take them back or offer to do so voluntarily. - Up to three waste electrical devices per type of device, with an edge length of no more than 25 centimetres, can be returned free of charge to the manufacturer without prior purchase of a new device from the manufacturer or taken to another authorised collection point in your vicinity.
Fault Possible cause Remedy
No supply voltage. Check the supply voltage, the power plug and the socket-outlet.
Insufficient supply voltage. Make sure that the extension cable is not too long. Use an extension cable with large enough wires.
The compressor does not start.
Outside temperature is too low. Never operate with an outside temperature of below +5° C.
Motor is overheated. Allow the motor to cool down. If necessary, remedy the cause of the overheating.
The non-return valve (9) leaks. Have a service center replace the non-return valve.
The compressor starts but there is no pressure.
The seals are damaged. Check the seals and have any damaged seals replaced by a service center.
The drain plug for conden- sation water (3) leaks.
Tighten the screw by hand. Check the seal on the screw and replace if necessary.
The hose connections have a leak.
Check the compressed air hose and tools and replace if necessary.
The compressor starts, pressure is shown on the pressure gauge, but the tools do not start.
A quick-lock coupling has a leak. Check the quick-lock coupling and replace if necessary.
Insufficient pressure set on the pressure regulator (11). Increase the set pressure with the pressure regulator.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.