The use of symbols in this manual is intended to draw your attention to possible risks. The safety symbols and the explanations that accompany them must be perfectly understood. The warnings in themselves do not remove the risks and cannot replace correct actions for preventing accidents.
Dispose of waste oil correctly (waste oil collection point on site). Do not dump waste oil in the ground or mix it with waste.
Do not remove or modify protection and safety devices.


The machine must only be operated by one person!
Loosen the vent bolt two revolutions, before starting work. Close before transport.
Do not transport the device in the horizontal position!
m Attention! In this operating manual, we have used this sign to mark all sections that concern your safety.



We accept no liability for accidents or damage that occur due to a failure to observe this manual and the safety instructions.
Dear Customer, We hope your new tool brings you much enjoyment and success.
A. Splitter B. Supporting arm C. Log lifter D. Holder arm for trunk lifter E. Enclosed accessories bag F. Operating manual
We recommend: Read through the complete text in the operating in- structions before installing and commissioning the device. The operating instructions are intended to help the user to become familiar with the machine and take advantage of its application possibilities in accordance with the recommendations. The operat- ing instructions contain important information on how to operate the machine safely, professionally and economically, how to avoid danger, costly repairs, re- duce downtimes and how to increase reliability and service life of the machine. In addition to the safety regulations in the operating instructions, you have to meet the applicable regu- lations that apply for the operation of the machine in your country. Keep the operating instructions pack- age with the machine at all times and store it in a plastic cover to protect it from dirt and moisture. Read the instruction manual each time before op- erating the machine and carefully follow its informa- tion. The machine can only be operated by persons who were instructed concerning the operation of the machine and who are informed about the associat- ed dangers. The minimum age requirement must be complied with. In addition to the safety instructions in this operating manual and the separate regulations of your country, the generally recognised technical rules for operat- ing woodworking machines must also be observed.
The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufactur- er will be liable for any damage or injuries of any kind caused as a result of this. The equipment is to be operated only with suitable saw blades. It is prohibited to use any type of cut- ting-off wheel. To use the equipment properly you must also ob- serve the safety information, the assembly instruc- tions and the operating instructions to be found in this manual. All persons who use and service the equipment have to be acquainted with this manual and must be in- formed about the equipment’s potential hazards. It is also imperative to observe the accident preven- tion regulations in force in your area. The same ap- plies for the general rules of health and safety at work. The manufacturer will not be liable for any changes made to the equipment nor for any damage resulting from such changes. • The hydraulic log splitter can only be used in a ver- tical position. Logs may only be split along the di- rection of the fiber. Log dimensions are: Log lengths 106 cm Ø min. 10 cm, max. 40 cm

The machine may be operated only with original parts and original accessories of the manufacturer. The safety, work and maintenance instructions of the manufacturer as well as the dimensions indicat- ed in the Technical Data section must be adhered to.
Please note that our equipment has not been de- signed for use in commercial, trade or industri- al applications. Our warranty will be voided if the equipment is used in commercial, trade or industrial businesses or for equivalent purposes.

Open the packaging and remove the device carefully. Remove the packaging material as well as the pack- aging and transport bracing (if available). Check that the delivery is complete. Check the device and accessory parts for transport damage. In case of complaints the dealer must be informed immediately. Subsequent complaints will not be ac- cepted. If possible, store the packaging until the warranty pe- riod has expired. Read the operating manual to make yourself familiar with the device prior to using it. Only use original parts for accessories as well as for wearing and spare parts. Spare parts are available from your specialized dealer. Specify our part numbers as well as the type and year of construction of the device in your orders.
m ATTENTION The device and packaging materials are not toys! Children must not be allowed to play with plas- tic bags, film and small parts! There is a risk of swallowing and suffocation!
9.1 Mount (14) wheels (fig. 2) Slide the wheel axle Through the drilled hole on the bottom, rear end of the splitter. Now insert the wheels on the wheel axle and fasten them with two splints.
Motor V/Hz 230V / 50Hz
9.2 Mount (2) controller handles (fig. 3) Insert the controller arm with slotted hole onto the rocker switch (b) and the drilled hole onto the threaded rod (a) . Secure the controller arm with a washer and fasten it with a spring splint pin on the rocker switch and a self-locking nut on the threaded rod. Now fasten the other control arm on the other side in accordance with the method described
Input P1 W 3700
Output P2 W 2700
Operating mode S6 40%
Motorspeed min-1 2800
Dimensions D/W/H 1030 x 990 x 2370 mm
Log length 1060 mm
Power max. tons* 10
9.3 Mount (12) holder arm (fig. 4) Insert both holder arms into the rectangular steel tubes, which are located on the left side of the splitter. Fasten the holder arms with two M10 x 45 mm hexagon screws and self/locking nuts each.
Piston stroke 860 mm
Forward speed cm/s 6
Return speed cm/s 7
Oil quantity l 9
9.4 Mount (6) holder arm for trunk lifter (fig. 5) Fasten the holder arm with two hexagonal screws (M10 x 25) on the frame, but do not tension the screws tightly yet. (more at 9.5)
Subject to technical changes!
Drive E-motor · Phase inverter yes · Weight kg 168

9.5 Mount (5) trunk lifter (fig. 6) Fasten the trunk lifter with a hexagon screw (M10 x 55) and a self-locking nut between both of the brackets, which are located on the right, lower end of the splitter. Next, align the holder arm (6) on the trunk lifter. A gap of approx. 0.5 - 1 mm must be present between the holder arm and trunk lifter. Next, cut in the chain (4) on the splitting blade. (fig. 7)
If the splitting blade does not move despite activation of the handles or return bracket, immediately turn off the machine. Turn the pole reversing unit in the plug- in module (Fig. 10) to change the rotational direction of the motor.
Never let the motor run in the wrong direction! This will inevitably destroy the pump system and no warranty claim can be made.
9.6 Putting the splitter into the work position Connect the splitter to the mains power. Be aware of the motor’s direction of rotation. Lower both controller handles until the cylinder is present above the drilled holes (d) is located in the upper position. Insert both shafts into the drilled holes and secure them with spring pins. Then bring the splitting blade to the top position and remove the support. You must store the support safe- ly because it is needed every time the splitter is trans- ported.
Functional test Test the function before every use.
Push both handles towards below.
Splitting knife goes down to approx. 20 cm above the table.
Let one handle loose, then the other.
Splitting knife stops in the desired position.
Warning! Loosen the filling screw (d) before commission- ing. Never forget to loosen the filling screw! Other- wise, the air in the system will constantly be com- pressed and decompressed with the result that the seals of the hydraulic circuit will be destroyed and the wood splitter can no longer be used. In this case, the seller and the manufacturer will not be liable to warranty services.
m IMPORTANT! You must fully assemble the appliance before using it for the first time!
Switching on and off (10) Press the green button for switching on. Press the red button for switching off. Note: Check the function of the ON/OFF unit before every use by switching on and off once.
Checking the oil level (fig. 9) The hydraulic unit is a closed system with oil tank, oil pump and control valve. Check the oil level regularly before every use. Too low an oil level can damage the oil pump. The level of oil must be checked when the riving knife is pulled back. If the oil level is at the lower notch, then the oil level is at a minimum. Should this be the case, oil must be immediately added. The upper notch indicates the maximum oil level. The ma- chine must be on level ground. Screw in the oil dip- stick fully, to measure the oil level.
Restarting safety in case of current interruption (no-volt release). In case of current failure, inadvertent pulling of the plug, or a defective fuse, the machine is switched off automatically. For switching on again, press anew the green button of the switch unit.
E- Motor Check the running direction of the motor. If the split- ting arm is not in the top position, bring the splitting blade in the top position, using the return bracket or handles. If the splitting arm is already in the top posi- tion, activate the splitting mechanism by moving both levers down. This will move the splitting arm down.

Such damaged electrical connection cables must not be used and are life-threatening due to the insula- tion damage.
Check the electrical connection cables for damage regularly. Make sure that the connection cable does not hang on the power network during the inspection.
Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use con- nection cables with the marking „H07RN“.
The printing of the type designation on the connec- tion cable is mandatory.
For single-phase AC motors, we recommend a fuse rating of 16A (C) or 16A (K) for machines with a high starting current (starting from 3000 watts)!
Three-phase motor 400 V / 50 Hz Mains voltage 400 V / 50 Hz Mains voltage and extension cables must be 5-lead (3P + N + SL (3/N/PE). Extension cables must have a minimum cross-section of 1.5 mm². Mains fuse pro- tection is 16 A maximum.
Resetting the log lifter This is used as a second guard arm when not using the trunk lifter. For this, the arm is moved up until it locks in.
When connecting to the mains or relocating the ma- chine, check the direction of rotation (swap polarity in the wall socket if necessary). Turn pole inverter in the machine socket.
Transport position of the log lifter: • Using your hand, move the log lifter up until it locks in position.
Comply with these notices to ensure quick and safe work.
The electrical motor installed is connected and ready for operation. The connection complies with the ap- plicable VDE and DIN provisions.
Clean the equipment regularly with a damp cloth and some soft soap. Do not use cleaning agents or sol- vents; these may be aggressive to the plastic parts in the equipment. Ensure that no water can get into the interior of the equipment.
The customer‘s mains connection as well as the ex- tension cable used must also comply with these reg- ulations.

The system is complete when the machine is deliv- ered, and may not be changed or manipulated.
Before transporting the kindling splitter, ensure it is in the transport position. To do this, lower the riving knife until it rests on the metal support. Next, remove both shafts and allow the cylinder to move down- wards finally. You can set the splitter onto a palette with the help of a crane, but never lift the splitter by the splitting blade. The top part of the splitter features an eyelet, where the crane hook may be engaged.
Connections and repairs Connections and repairs of electrical equipment may only be carried out by an electrician.
Store the device and its accessories in a dark, dry and frost-proof place that is inaccessible to children. The optimum storage temperature is between 5 and 30˚C. Cover the electrical tool in order to protect it from dust and moisture. Store the operating manual with the electrical tool.
Service information Please note that the following parts of this product are subject to normal or natural wear and that the fol- lowing parts are therefore also required for use as consumables. Wear parts*: hydraulic oil, splitting wedge, Transmis- sion oil * Not necessarily included in the scope of delivery!
The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equip- ment and its accessories are made of various types of material, such as metal and plastic. Defective components must be disposed of as spe- cial waste. Ask your dealer or your local council.
When must the oil be changed? First oil change after 50 operating hours, then every 250 operating hours.
Oil change Position the kindling splitter on a slightly raised sur- face (e.g. euro pallet). Place a sufficiently large con- tainer (at least 15 litres) under the drain plug on the splitting column. Open the drain plug and carefully let the oil run into the container. Open the filling screw on the top of the split- ting column so the oil can drain more easily. Re- place the drain plug and its seal and tighten it.
Old devices must not be disposed of with house- hold waste!
This symbol indicates that this product must not be disposed of together with domestic waste in compliance with the Directive (2012/19/EU) pertaining to waste electrical and elec- tronic equipment (WEEE). This product must be dis- posed of at a designated collection point. This can occur, for example, by handing it in at an authorised collecting point for the recycling of waste electrical and electronic equipment. Improper handling of waste equipment may have negative consequences for the environment and human health due to poten- tially hazardous substances that are often contained in electrical and electronic equipment. By properly disposing of this product, you are also contributing to the effective use of natural resources. You can obtain information on collection points for waste equipment from your municipal administration, pub- lic waste disposal authority, an authorised body for the disposal of waste electrical and electronic equip- ment or your waste disposal company.
Pour in fresh hydraulic oil (Contents: see Technical data) and check the oil level with the dipstick. After changing the oil, operate the kindling splitter a few times without actually splitting.
We recommend oil from the HLP 32 range.
Hydraulic system The hydraulic unit is a closed system with oil tank, oil pump and control valve.

The table below contains a list of error symptoms and explains what you can do to solve the problem if your tool fails to work properly. If the problem persists after working through the list, please contact your nearest service workshop.
Malfunction Possible cause Remedy
No electric power Check cable for electric power
The hydraulic pump does not start
Thermal switch of motor cut off Engage thermal switch inside the motor casing again
Low oil level Check oil level and refill
The column does not move down
One of the levers not connected Check fixing of lever
Dirt in the rails Clean the column
Motor starts but column does not move down
Wrong turning direction of 3-phase motor Check turning direction of motor and change
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.