Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device. !

Function / application High-performance laser receiver with extremely large receiving range for red and green rotary lasers – Receives information on the height which is shown on LC displays at front

and rear and by three bright LEDs to the front – Beep acts as acoustic signal – LC displays show the height difference to the laser level and graphically

using arrows and the central line as well as numerically

General safety instructions – The device must only be used in accordance with its intended

purpose and within the scope of the specifications. – The measuring tools and accessories are not toys.

Keep out of reach of children. – The structure of the device must not be modified in any way. – Do not expose the device to mechanical stress, extreme temperatures

or significant vibration. – The device must no longer be used if one or more of its functions

fail or the battery charge is weak. – Risk of pinching! Do not reach into the clamping bracket!

Safety instructions Dealing with electromagnetic radiation – The measuring device complies with electromagnetic compatibility

regulations and limit values in accordance with EMC-Directive 2014/30/EU. – Local operating restrictions – for example, in hospitals, aircraft, petrol

stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Page 2 of the Laserliner SensoMaster (M350) user manual
Seite 2 · Zum Vergrößern klicken
Seite 2
Laserliner SensoMaster (M350) diagram (page 2)
Abb. 1

A quality product from GmbH & Co. KG Donnerfeld 2, 59757 Arnsberg Germany, Tel.: +49 2932 638-300 Fax: -333, www.laserliner.com

Laserliner SensoMaster (M350) diagram (page 2)
Abb. 2
4Loudspeaker beep 5Horizontal vial 6Receiver field for laser beam 7LC display 8All-round marking groove 9Convert unit cm / mm; Backlighting ON/OFF 10Accurancy 11Threaded hole for locating the universal retainer 12Magnets 13LC display (rear side) 14Battery compartment
b Numeric elevation c Gra Han precde indication arrows: d-held receiver below, isely on or above laser d Loudspeaker beep indicat e Accuracy (deadband) indic f Lowbattery indicator g Backlighting ON/OFF
2 Vertical vial 3 ON/OFF button
Page 3 of the Laserliner SensoMaster (M350) user manual — OFF
Seite 3 · Zum Vergrößern klicken
Seite 3

Special product features and functions

The receiver speeds up response times - rapid detection accelerates work rates.

For many measuring tools, the key to optimum working is magnetic adhesion. This leaves the hands free to complete other tasks.

IP 66

Protection against dust and water – The laser receiver is exceptionally well protected against dust and rain.

Insertion of batteries Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.

ON/OFF 2

ON

In order to preserve the battery life, the receiver switches off automatically if it is not used for around 15 minutes.

OFF

magnetic · 2 sec · 1 sec

Page 4 of the Laserliner SensoMaster (M350) user manual — Special product features and functions
Seite 4 · Zum Vergrößern klicken
Seite 4

Working with the laser receiver Set the rotary laser to maximum speed and switch the laser receiver on. It is able to detect the laser beam at a great distance now. Move the SensoLite up and down through the laser beam until the middle indicator appears. Mark the measured height at the perimeter marking groove.

Laserliner SensoMaster (M350) — Special product features and functions diagram (page 4)
Abb. 3 · Special product features and functions

Slow beeping Continuous tone = mark the reference Fast beeping

Grade indication arrows 4 5 individual levels of grade information for above and below grade. Horizontal bar indicates on-grade.

Laserliner SensoMaster (M350) — Special product features and functions diagram (page 4)
Abb. 4 · Special product features and functions

Out-of Beam display: a sequence of arrows will indicate if the receiver has moved beyond the vertical reception range and will indicate which direction to move to get back to the laser beam. The display can be turned on or off.

Page 5 of the Laserliner SensoMaster (M350) user manual — Backlighting
Seite 5 · Zum Vergrößern klicken
Seite 5

Accurancy

Set the accuracy by pressing button 10.

Switch between the three accuracies, coarse, medium or fine, by repeatedly pressing the button.

Switch units of measurement

Select centimetres (cm) or millimetres (mm) as the unit of measurement by briefly pressing button 9.

Backlighting

The backlighting is switched ON/OFF by pressing and holding button (9).

Loudspeaker beep 8 Toggle button 4 to set the volume to loud, quiet or off. One beep is emitted at the selected volume when changed.

Universal mount The laser receiver can be installed on levelling staffs with the aid of the universal mount. The Flexi measuring staff is always recommended when measuring from floor heights. It also allows you to determine heights directly without any need for calculation.

Coarse Medium Fine

Page 6 of the Laserliner SensoMaster (M350) user manual — Accurancy
Seite 6 · Zum Vergrößern klicken
Seite 6

Danger - powerful magnetic fields Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks). With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety - electromagnetic fields) in the Federal Republic of Germany. To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm away from the magnet.

Information on maintenance and care Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

EU directives and disposal This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: http://laserliner.com/info?an=AHU

Page 7 of the Laserliner SensoMaster (M350) user manual — Technical data
Seite 7 · Zum Vergrößern klicken
Seite 7

Technical data

Laser reception range 350 m (The maximum range depends on the rotary laser) Length of receiver unit 127 mm Necessary rotation speed 300 - 1100 RPM

± 1 mm / 50 m ± 5 mm / 50 m ± 10 mm / 50 m Auto power off 15 minutes Protection class IP 66 Power supply 4 x 1.5V LR6 (AA) Operating time approx. 40 hours

0°C...50°C, max. humidity 80% rH, no condensation, max. working altitude 4000 m above sea level

Storage conditions 0°C...70°C, max. humidity 80% rH Weight (incl. batteries, without universal retainer) 426 g

Dimensions (W x H x D) 77 x 178 x 35 mm

Subject to technical alterations. 21W12

Accuracy (deadband, absolute) · Operating conditions

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Laserliner SensoMaster (M350) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Laserliner SensoMaster (M350)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Laserliner SensoMaster (M350) PDF-Anleitung

72 Seiten·1.9 MB·Sensor·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…