ponds and in the protected areas around them, the provisions of DIN VDE 0100-702 and -738 must be observed. The device must be supplied via a residual-current device (RCD) with a rated residual current of max. 30 mA. The device must not be used if there are persons in the water. When used for domestic water supply, the statutory water and waste water specifications according to DIN 1988 must be observed. The following residual risks essentially remain when operating pumps and pressure vessels can- not be fully eliminated (depending on features) – even if safety meas- ures have been introduced.
4.3 Danger! Risk of electric shock! Never direct the water jet directly at the device or other electrical components! Risk of fatal electric shock! Prior to installation and mainte- nance tasks, always disconnect the device from the power-supply system. Do not touch the plug with wet hands! To disconnect, always pull on the plug, not the power cable. Do not buckle, squeeze, drag or drive over power cable or exten- sion cables; protect from sharp edges, oil and heat.
Under our sole responsibility, we hereby declare that these pumps/domestic water systems, identi- fied by type and serial number *1), comply with all relevant requirements of the directives *2) and standards *3). Technical documents for *4) - see Page 3.
This device is used for conveying clean water in the house and garden area, for sprinkling and watering, as a well pump, rain pump and domestic water pump and for pumping out swimming pools, garden ponds and water tanks. The maximum permissible temperature of the conveyed medium is 35 °C. The device must not be used for drinking water supply or for conveying food supplies. Explosive, combustible, aggressive or other substances that are harmful to health must not be conveyed. The device is not suitable for commercial or indus- trial use. This device is not designed for the use of persons with limited physical, sensory or mental aptitude or lack of experience and/or knowledge. Children should be supervised to ensure that they do not play with the device. Unauthorised modifications to the device and the use of parts that are not tested and approved by the manufacturer are prohibited. All improper use of the device is regarded as non- specified use; this can result in unpredictable damage! The user bears sole responsibility for any damage caused by improper use. Generally accepted accident prevention regula- tions and the enclosed safety information must be observed.
4.4 Danger due to device defi- ciencies or malfunctions! Before each use, check the device for possible damage - especially the mains cable, mains plug and electrical components. Risk of fatal electric shock! A damaged device must only be reused after it has been correctly repaired. Do not attempt to repair the pump yourself! Only specialists are per- mitted to repair pumps and pres- sure vessels (depending on fea- tures).
4.1 Danger from the environ- ment! Do not expose device to rain. Do not operate device in a damp or wet environment. Do not use the pump in hazardous locations or near inflammable liq- uids and gases!
For your own protection and for the protection of your device, pay attention to all parts of the text that are marked with this symbol! WARNING – Reading the operating instructions will reduce the risk of injury.
4.2 Danger: Hot water! Danger! Install a check valve at the suction connection (4) to prevent water from flowing back into the suction line. This can reduce the following danger: Hot water can cause damage and leaks on the pump and the con- nection lines, allowing hot water to escape. Danger of scalding! Devices with the designation HWW...: If the shut-off pressure of the pressure switch cannot be reached due to poor pressure conditions or a defective pressure switch, the water can heat up within the pump as a result of internal circulation. Devices with the designation P...: Operate the pump a max. of 5 min- utes against the closed discharge line. Water that circulates inside the device is heated up. In the event of a fault, unplug the pump from the power-supply sys- tem and allow to cool. A specialist must check the system to make sure it is in perfect working order before it can be used again.
ures, e.g.: alarm system or col- lecting tank with monitor The manufacturer is not liable for any damage caused by: - improper use of the pump; - overloading of the pump through
pump in a frost-free environment; - unauthorised modification of the
pump (repairs to electrical equip- ment may only be carried out by qualified electricians!); - use of spare parts which have
Children, adolescents and per- sons who are not familiar with the operating instructions must not used the device. Never allow children to use the machine. Children should be supervised to ensure that they do not play with the tool. When the pump is being used in swimming pools and garden
not been tested and approved by the manufacturer; or - use of unsuitable installation
materials (fittings, connection lines etc.). Suitable installation materials: - pressure-resistant (min. 10 bar) - heat-resistant (min. 100 °C).
ENGLISH en

When using universal swivel cou- plings (bayonet couplings), only use versions with an additional securing ring to ensure safe seal- ing.
the discharge line can burst during operation. Inju- ries are possible if highly pressurised fluids are ejected!
6.5 Connection to a pipe network To reduce vibration and noises, the device should be connected with flexible hose lines to the pipe network.
Domestic water system (device designation HWW...) Functional principle: the device switches on when the removal of water causes the water pressure to fall below the switch-on pressure; it switches off again when switch-off pressure is reached. The pressure vessel contains a rubber bellows, which is under air pressure (pilot pressure) when deliv- ered; this permits the removal of small volumes of water without the pump starting up. 1. Insert mains plug. 2. Turn on at switch (8). 3. Open the discharge line (open water tap or spray nozzle). 4. Check that water emerges!
6.6 Mains connection Danger! Risk of electric shock! Never operate the device in a wet environment and only under the following conditions: - Connect only to an earthed outlet
See page 2. The illustrations serve as examples for all devices.
1 Water drain screw 2 Pressure switch * 3 Pressure gauge (water pressure) * 4 Suction connection 5 Water filling screw 6 Pressure connection 7 Pump 8 On/off switch 9 Air valve for pilot pressure * 10 Pressure vessel * * depending on model
and fuse protection must corre- spond to those stated in the 'Technical Specifications'. - The device must be supplied via
- Unplug mains cable. - Ensure that the device and connected accesso-
ries are depressurised. - Repair and maintenance work other than
6.1 Setting pilot pressure Set the pilot pressure before initial operation. See section 9.4.
a residual-current device (RCD) with a rated residual current of max. 30 mA. - The electrical connections must
described in this section should only be carried out by qualified specialists.
8.1 Regular maintenance - Check device and accessories, in particular,
6.2 Installation The device must be positioned on a horizontal, flat surface that is suitable for the device weight with water filling. To avoid vibrations, the device should not be bolted on but rather should be positioned on a resilient base. The place of installation should be well ventilated and protect against weather influences. Protect against frost - see section 8.2. For operation in garden ponds and swimming pools, the device must be installed in a flood-proof loca- tion and secured against falling in. Additional statutory requirements must be taken into consideration.
not be under water and must be located in a flood-proof area. The connections must be splash- proof for outdoor use. - Extension cables must have
electrical and pressurised components, for damage and repair if necessary. - Check suction and discharge lines for leaks. - If the conveying capacity decreases, clean intake
filter and filter element (if installed) and replace if necessary. - Check the pilot pressure of the pressure vessel
(10) (depending on features) and increase it if necessary (see section 9.4 Increasing pilot pres- sure).
tions must be observed.
8.2 Danger of frost Caution! Frost (< 4 °C) destroys the pump and accessories as both always contain water! - If there is a danger of frost, disassemble pump
6.7 Filling pump and suction Caution! In the case of a new connection, water loss or air intake, the pump must be filled with water. Operation of the pump without water filling will destroy it! - Unscrew water filling screw (5) including gasket. - Slowly pour in clean water until the pump is filled. - Screw in water filling screw (5) with gasket again. - Open the discharge line (open water tap or spray
and accessories and store in frost-free condi- tions (see following section).
6.3 Connecting suction line Caution! The suction line must be installed such that no mechanical or twisting forces are exerted on the pump.
8.3 Removing and storing device - Turn off at switch (8). Unplug mains cable. - Open the discharge line (open water tap or spray
nozzle), allow water to drain off completely. - Completely drain the pump (7) and vessel (10)
nozzle) so that air can escape during suction. - Switch on the device (see section 7.). - When water emerges evenly, the device is ready
Caution! Use an intake filter to protect the pump against sand and contamination. Caution! The check valve is absolutely necessary to prevent the water from draining when the pump is switched off. We recommend the installation of check valves at the intake opening of the suction hose and at the suction connection (4) of the pump. Depending on the model, a check valve may already be integrated (see section 13. Technical Specifications). Seal all screw-coupling with thread sealing tape. Leaks result in air intake and reduce or prevent the water intake. The suction line should have an inside diameter of at least 1" (25 mm); it must be kink- and vacuum- resistant. The suction line should be as short as possible because the longer the line length, the lower the conveying capacity. The suction line should rise uniformly towards the pump to prevent air inclusions. A sufficient water supply must be guaranteed and the end of the suction line should always be under water.
for operation. Note: The suction line does not need to be filled because the pump is self-priming. Depending on the length and diameter of the line, however, it may take some time until pressure is built up. To shorten the suction time: install a check valve at the intake opening of the suction hose and fill the suction line too.
device. - Store device in a frost-free room (min. 5 °C).
ries are depressurised.
9.1 Pump is not running • No mains voltage. - Check on/off switch, cables, plug, socket and
mains fuse. • Mains voltage too low. - Use an extension cable with sufficient
7.1 Using the device
conductor diameter. • Motor overheated; motor protection relay tripped.
Pump (device designation P...) Functional principle: the device runs as long as the on/off switch (8) is activated.
6.4 Connecting the discharge line Caution! The discharge line must be installed such that no mechanical or twisting forces are exerted on the pump. Seal all screw-couplings with thread sealing tape to prevent water discharge. All components of the discharge line must be pres- sure-resistant and installed correctly.
- After cooling the pump will switch on again. - Guarantee sufficient ventilation, keep air slots
free. - Observe maximum supply temperature. • Motor hums, but does not start. - With the motor switched off, insert a screw-
driver or similar object through the air slots on the motor and turn the fan impeller.
ENGLISH en · f

You can download spare parts lists from www.metabo.com
replace if necessary. Clean impeller, replace if necessary. See section 11.
Observe national regulations on environmentally compatible disposal and on the recycling of disused machines, packaging and accessories.
Only for EU countries: Never dispose of power tools in your household waste! In accordance with European Guideline 2002/ 96/EC on used electronic and electric equipment and its implementation in national legal systems, used power tools must be collected separately and handed in for environmentally compatible recy- cling.
Explanatory notes on the specifications on page 3. Changes due to technological progress reserved. The pump characteristic curve (diagram on page 3) shows the conveying capacity that can be reached depending on the conveying height (suction height 0.5 m and 1" suction hose). U =Mains voltage f =Frequency P1 =Rated power I =Rated current C =Operating condenser n =Rated speed FV,max =max. conveying capacity Fh,max =max. conveying height Fp,max =max. conveying pressure p1 =Pressure switch: switch-on pressure p2 =Pressure switch: switch-off pressure Sh,max =max. suction height Stemp =max. supply temperature Ttemp =Ambient temperature S1 =Splash protection class S2 =Protection class S3 =Insulation class MP =Pump housing material
the pressure gauge (3) and check values (see section 13 Technical Specifications). If an adaptation is necessary, please contact Metabo Customer Service. See section 11. • HWW...: Pump starts up even after removal of small volume of water (approx. 0.5 l). - Check whether the pilot pressure in the pres-
G = Grey cast iron MR =Pump shaft material MW =Pump impeller material Ds =Suction connection female thread Dp =Pressure connection female thread TV =Pressure vessel volume Tp,max =max. vessel pressure Tp,1 =Vessel pilot pressure A =Dimensions:
sure vessel is too low. Increase pressure if necessary. See section 9.4. • HWW...: Water is running out of the air valve. - Rubber bellows in pressure vessel leaking,
replace it. See section 11.
Length x Width x Height m =Weight (with mains cable) ~ Alternating current The technical specifications quoted are subject to tolerances (in compliance with the relevant valid standards).
9.4 Increasing pilot pressure (only HWW...) If – in the course of time – the pump starts up even after the removal of a small volume of water (approx. 0.5 l), the pilot pressure in the vessel must be restored. Note: The pilot pressure cannot be read off at the pressure gauge (3). 1. Unplug mains cable. 2. Open the discharge line (open water tap or spray nozzle), allow water to drain off completely. 3. Unscrew plastic cap on front face of pressure vessel; the air valve is located behind it. 4. Mount air pump or compressor hose with a "tyre valve" connection and pressure gauge on the air valve. 5. Pump up to the specified pilot pressure (see section 13. Technical Specifications). 6. Connect device again and check operation.
Emission values Using these values, you can estimate the emissions from this power tool and compare these with the values emitted by other power tools. The actual values may be higher or lower, depending on the particular application and the condition of the tool or power tool. In estimating the values, you should also include work breaks and periods of low use. Based on the estimated emission values, specify protective measures for the user - for example, any organisational steps that must be put in place. Typical A-effective perceived sound levels:: LpA =Sound pressure level LWA =Acoustic power level KpA, KWA= Uncertainty LWA(G) =Guaranteed acoustic power level as per
2000/14/EC
Use only genuine Metabo accessories. Use only accessories that fulfil the requirements and specifications listed in these operating instruc- tions. For a complete range of accessories, see www.metabo.com or the catalogue.
ENGLISH en · f · Wear ear protectors!
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.