Perel EVM892

80 Seiten·799 KB·Messgeräte·PDF·ENITJA
Perel EVM892
Inhaltsverzeichnis 17 Abschnitte MULTIFUNCTIONAL DIGITAL MULTIMETER · MULTIFUNCTIONELE DIGITALE MULTIMETER · MULTIMÈTRE NUMÉRIQUE MULTIFONCTIONS · MULTÍMETRO DIGITAL MULTIFUNCIÓN · … AnzeigenAusblenden
Page 1 of the Perel EVM892 user manual — MULTIFUNCTIONAL DIGITAL MULTIMETER
Seite 1 · Zum Vergrößern klicken
Seite 1

MULTIFUNCTIONAL DIGITAL MULTIMETER

MULTIFUNCTIONELE DIGITALE MULTIMETER

MULTIMÈTRE NUMÉRIQUE MULTIFONCTIONS

MULTÍMETRO DIGITAL MULTIFUNCIÓN

MULTIFUNKTIONALES DIGITALMULTIMETER

Perel EVM892 — MULTIFUNCTIONAL DIGITAL MULTIMETER diagram (page 1)
Abb. 1
Perel EVM892 — MULTIFUNCTIONAL DIGITAL MULTIMETER diagram (page 1)
Abb. 2

USER MANUAL 3 GEBRUIKERSHANDLEIDING 14 NOTICE D’EMPLOI 27 MANUAL DEL USUARIO 39 BEDIENUNGSANLEITUNG 51 MANUAL DO UTILIZADOR 64

Page 2 of the Perel EVM892 user manual — MULTIFUNCTIONAL DIGITAL MULTIMETER
Seite 2 · Zum Vergrößern klicken
Seite 2
Perel EVM892 — MULTIFUNCTIONAL DIGITAL MULTIMETER diagram (page 2)
Abb. 3
Perel EVM892 — MULTIFUNCTIONAL DIGITAL MULTIMETER diagram (page 2)
Abb. 4
Page 3 of the Perel EVM892 user manual — 2. Used symbols
Seite 3 · Zum Vergrößern klicken
Seite 3

User manual

1. Introduction

To all residents of the European Union Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. The DVM892 is a 600V CAT II digital multi-meter with a 3½ digit LCD. This device is can be used to measure direct and alternating voltages, direct and alternating currents, resistance, continuity, capacity, temperature, frequency, diode and transistors (hFE). Be very careful when using this device: carelessness can lead to serious or even fatal injury. Besides the usual safety-precautions for working with electrical circuits you must follow the safety guidelines as described in this manual. Do not use this device if you do not have preliminary knowledge of circuits and test procedures. This device is not suitable for commercial or industrial use. Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.

2. Used symbols

This symbol indicates: Read instructions Not reading the instructions and manual can lead to damage, injury or death.

This symbol indicatesDanger A hazardous condition or action that may result in injury or death

This symbol indicates: Risk of danger/damage Risk of a hazardous condition or action that may result in damage, injury or death

This symbol indicates: Attention; important information Ignoring this information can lead to hazardous situations.

alternatingA

= alternating current (AC); V

directA

= direct current(DC); V

Double insulation (class II-protection)

Show 6 more labels / short text on this page
= AC voltages · =DC voltages · Earth · Fuse · Resettable fuse · Diode
Page 4 of the Perel EVM892 user manual — ON/OFF
Seite 4 · Zum Vergrößern klicken
Seite 4

ON/OFF

3. Warnings and safety instructions

Read this manual thoroughly. Familiarise yourself with the functions of the device before actually using it.

Only use the device for its intended purpose. Using the device in an unauthorized way will void the warranty. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.

Keep the device away from children and unauthorised users.

Protect this device from shocks and abuse. Avoid brute force when operating.

Avoid cold, heat and large temperature fluctuations. When the unit is moved from a cold to a warm location, leave it switched off until it has reached room temperature. This to avoid condensation and measuring errors.

This is an installation category CAT II 600V measuring instrument. Never use this equipment in a higher category than indicated. Refer to §4 Overvoltage /installation category.

Pollution degree 2-device. For indoor use only. Keep this device away from rain, moisture, splashing and dripping liquids. Not for industrial use. Refer to §5 Pollution degree.

Before each use, make sure the test probes are in good condition. Always place your fingers behind the protective edges of the test probes while measuring! Never touch free terminals when the meter is connected to a circuit.

Make sure the meter is in the appropriate measuring range before connecting it to a test circuit.

Risk of electric shock during operation. Be very careful when measuring live circuits. Use extreme caution when measuring voltages higher than 60Vdc or 30Vac rms.

Do not measure circuits that may contain voltages > 600V

Do not measure current in circuits with voltages > 250V

Do not conduct resistance, diode- or continuity measurements on live circuits. For transistor tests, use the included transistor socket.

Continuity · /

Page 5 of the Perel EVM892 user manual — 4. Overvoltage/installation category
Seite 5 · Zum Vergrößern klicken
Seite 5

When measuring currents up to 10A, max. 10s continuous measurement followed by a 15 minutes break between 2 measurements.

When carrying out measurements on a TV set or switching power circuits, always be aware that high amplitude voltage pulses at the test points might damage the meter.

Do not replace internal parts yourself. Replace damaged or lost accessories by identical ones with the same specifications. Order spare accessories e.g. test probes at your dealer.

Switch off the meter and remove test probes prior to replacing the battery or fuses.

All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.

4. Overvoltage/installation category

DMMs are categorized depending on the risk and severity of transient overvoltage that might occur at the point of test. Transients are short-lived bursts of energy induced in a system, e.g. caused by lightning strike on a power line.

The existing categories according EN 61010-1 are:

CAT IA CAT I-rated meter is suitable for measurements on protected electronic circuits which are not directly connected to mains power, e.g. electronics circuits, control signals… CAT IIA CAT II-rated meter is suitable for measurements in CAT I-environments and mono-phase appliances which are connected to the mains by means of a plug and circuits in a normal domestic environment, provided that the circuit is at least 10m apart from a CAT IIIor 20m apart from a CAT IVenvironment. E.g. household appliances, portable tools… CAT IIIA CAT III-rated meter is suitable for measurements in CAT Iand CAT IIenvironments, as well as for measurements on (fixed) monoor polyphased appliances which are at least 10m apart from of a CAT IVenvironment, and for measurements in or on distribution level equipment (fuse boxes, lighting circuits, electric ovens). CAT IVA CAT IV-rated meter is suitable for measuring in CAT I-, CAT IIand CAT III-environments as well as on the primary supply level. Note that for all measurements on equipment for which the supply cables run outdoors (either overhead or underground) a CAT IV meter must be used.
  • This device is suitable for measurements up to 600V on:
  • Protected electronic circuits which are not directly connected to mains power, e.g. electronics circuits, control signals, circuits behind isolating transformer…
  • circuits which are directly connected to mains power, but limited to:
Page 6 of the Perel EVM892 user manual — 5. Pollution degree
Seite 6 · Zum Vergrößern klicken
Seite 6
  • o measurements on mono-phase appliances which are connected to the mains by means of a plug o mono-phase appliances and circuits directly connected to the mains in a normal domestic environment, provided that the circuit is at least 10m apart from a CAT IIIor 20m apart from a CAT IV-environment. E.g. household appliances, portable tools, light circuits at more than 10m from a distribution board … This device is NOT suitable for:
  • Voltages above 600V
  • measurements in/on low-voltage distribution boards (distribution boards behind meter box)
  • measurements on (fixed) monoor poly-phased appliances and circuits in CAT III / CAT IV-environments (e.g. mains outlets, electric ovens, lighting circuits, bus bars, low-voltage distribution boards and circuit breakers).
  • Measurements on distribution equipment and outdoor installations including meter boxes and equipment/circuits outside or remote from the domestic environment e.g. circuits in sheds, garden houses and free-standing garages , or circuits using underground wiring e.g. garden lighting, pool-pump...

This device is only suitable for measurements up to 600V in CAT II environments.

5. Pollution degree

IEC 61010-1 specifies different types of pollution environments, for which different protective measures are necessary to ensure safety. Harsher environments require more protection, and the protection against the pollution which is to be found in a certain environment depends mainly on the insulation and the enclosure properties. The pollution degree rating of the DVM indicates in which environment the device may be used.

Pollution degree 1No pollution or only dry, nonconductive pollution occurs. The pollution has no influence (only to be found in hermetically sealed enclosures). Pollution degree 2Only nonconductive pollution occurs. Occasionally, temporary conductivity caused by condensation is to be expected (home and office environments fall under this category). Pollution degree 3Conductive pollution occurs, or dry nonconductive pollution occurs that becomes conductive due to condensation that is to be expected (industrial environments and environments exposed to outside air - but not in contact with precipitation). Pollution degree 4The pollution generates persistent conductivity caused by conductive dust or by rain or snow. (exposed outdoor environments and environments where high humidity levels or high concentrations of fine particles occur)

This device is only suitable for measurements in Pollution degree class 2 environments.

Page 7 of the Perel EVM892 user manual — 7. Maintenance / battery and fuse replacement
Seite 7 · Zum Vergrößern klicken
Seite 7

6. Description of the front panel

Refer to the illustrations on page 2 of this manual.

1LCD 2Power ON/OFF button 3"10A" jack 4"mA/TEMP/CAP/hFe" jack
5"COM" jack 6"VΩHz" jack 7RANGE and FUNCTION switch

This push-button activates and deactivates the device. The DVM892 is also equipped with an energy-saving feature: the meter is automatically deactivated when the RANGE and FUNCTION selector has not been used for 15 minutes. The user will have to press the ON/OFF button twice to switch the device on again when the energy-saving feature has deactivated the DVM892.

RANGE and FUNCTION switch

This rotary switch is used to select the desired range or function. Always remove the test probes from the device under test before selecting a different range/function!

7. Maintenance / battery and fuse replacement

Do not replace internal parts yourself. Replace damaged or lost accessories by identical ones with the same specifications. Order spare accessories e.g. test probes at your dealer.

Switch off the meter and remove test leads prior to replacing the battery or fuses.

a. General maintenance: • Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol, solvents or abrasive products. b. Battery/fuse replacement

  • Replace the battery as soon as the “
  • ” indication appears on the display. Low/bad batteries can produce false readings. The fuse rarely needs to be replaced and a blown fuse is almost always caused by a human error.
  • Switch off the multi-meter.
  • Remove test probes from the circuit under test. Remove all test leads from the input jacks.
  • Remove the protective cover and release the three screws at the back of the meter and gently open the housing.
  • Replace the battery (9V 6LF22). Do not use rechargeable batteries and insert following the right polarity.
  • To replace the fuse, carefully release the 4 screws that hold the PCB; these screws are located at the top, around the LCD.
  • Gently lift the PCB.

Power ON/OFF button

Page 8 of the Perel EVM892 user manual — 9. Operating instructions
Seite 8 · Zum Vergrößern klicken
Seite 8
  • Replace the fuse (ceramic – high breaking capacity 5x20mm F10A/250V)
  • Place the PCB back. Make sure the LCD connection, buttons and jacks are lined up. Tighten the 4 screws.
  • Close the housing and tighten the 3 screws. Put the protective cover back.

8. Accessories

  • Set test probes 10A CAT II 600V
  • Thermo couple type K, RVS probe (max. 400°C)
  • Battery (inside meter)
  • User manual
  • Adaptor socket for easily measuring transistors and capacitors, and to connect thermocouples.
  • Cover: protects the meter and provides a comfortable grip. For positioning features, refer to the images on page 2 of this manual. A & B : Use either the small or large foldable stand C : Use the small stand to hang the meter to a wall: remove the small stand and

insert it in the slots near the top of the cover. Drive a nail in the wall and hang the meter. D: The test probes can be stored in the two provisions at the back.

9. Operating instructions

Risk of electric shock during operation. Be very careful when measuring live circuits.

  • Before measuring, always make sure the meter and/or test probes are not damaged and verify the connections, selected function and range.
  • Never exceed the limit value for protection. This limit value is listed separately in the specifications for each range of measurement.
  • Do not touch unused terminals when the meter is linked to a circuit which is being tested.
  • Only use the meter in the indicated overvoltage/installation category. Never measure voltages that might exceed the indicated category values.
  • Disconnect the test leads from the tested circuit before rotating the range selector in order to change functions.
  • When carrying out measurements on a TV set or switching power circuits, always remember that high amplitude voltage pulses at the test points might damage the meter.
  • Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers at all times during measurement.
  • Do not measure current in circuits with voltages > 250V
  • Never perform resistance, diode, transistor or continuity measurements on live circuits. Make sure all capacitors in the circuit are discharged.
  • Automatic power-off: The device will be deactivated automatically when the FUNCTION and RANGE switch has not been used for 15 minutes. This energy-saving feature extends the life of your battery.
Page 9 of the Perel EVM892 user manual — 8. Accessories
Seite 9 · Zum Vergrößern klicken
Seite 9

Limits of the meter:

FUNCTIONRED LEAD CONNECTIONINPUT LIMITS 200mVVΩHz250V DC or rms AC V& V ∼VΩHz600V DC, 600V AC (sine wave) HzVΩHz250V DC or rms AC ΩVΩHz250V DC or rms AC /VΩHz250V DC or rms AC mA& mAmA/temp/CAP/hFe200mA DC or rms AC 10 & 10A10A10A DC or rms AC for max. 10 seconds
  • Connect the black test lead to the "COM" jack and the red test lead to the "V Ω Hz" jack.
  • Select the appropriate V
  • (AC voltage) range with the FUNCTION switch. When the range is unknown, always select the highest possible range and lower to the appropriate range.
  • Connect the test probes to the circuit under test.
  • The measured value appears on the display. Notes :
  • For DC-measurements: when a negative polarity is present at the red test lead, the indicated value is preceded by a “-” sign.
  • When the measured value is higher than the selected range limit, the display will show “1”. Select a higher range.

Do not measure current in circuits with voltages > 250V

Current measurements: mA/TEMP/CAP/hFE jack max. 200mA; for measurements up to 10A use the 10A jack. When measuring currents up to 10A, max. 10s continuous measurement followed by a 15 minutes break between 2 measurements.

Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers at all times during measurement.

  • Connect the black test lead to the "COM" jack and the red test lead to the "mA/TEMP/CAP/hFE" jack for measurements of max. 200mA or to "10A" jack for measurements of max. 10A.
  • Select the appropriate A
  • (AC) range with the FUNCTION switch. Select the 200m/20m10 range when the red test lead is connected to the "mA/TEMP/CAP/hFE" jack; select the 20m10 range when the red test lead is connected to the "10A" jack. When the range is unknown, always select the highest possible range and lower to the appropriate range.
  • Connect the test probes in series with the circuit.
  • Read the measured value from the display. Notes:
Show 4 more labels / short text on this page
Measuring voltages · (DC voltage)or V · Measuring currents · (DC) or A
Page 10 of the Perel EVM892 user manual — 8. Accessories
Seite 10 · Zum Vergrößern klicken
Seite 10
  • For DC-current measurements, when a negative polarity is present at the red test lead, the indicated value is preceded by a “-” sign.
  • The mA-range is protected against over-current with an automatic resettable fuse type 200mA/250V; the 10A range is protected by a ceramic 10A/250V fuse.
  • When measuring currents up to 10A, max. 10s continuous measurement followed by a 15 minutes break between 2 measurements.

Do not perform resistance measurements on live circuits.

  • Connect the black test lead to the "COM" jack and the red test lead to the "V Ω Hz" jack.
  • Select the appropriate " Ω " range with the FUNCTION switch. When the range is unknown, always select the highest possible range and lower to the appropriate range.
  • Connect the test probes to the circuit/component under test.
  • The measured value appears on the display. Notes:
  • Never perform resistance measurements on a live circuit and make sure all capacitors are completely discharged.
  • To increase accuracy when measuring low resistance values, first hold the tips of the measuring probes together to determine the resistance value of the test leads. Subtract this value from the measured value of the circuit.
  • For resistance measurements above 1MΩ the meter needs a few seconds to stabilize the read-out.
  • Should the measured resistance exceed the selected range or in case of an open circuit, the display will show “1”.

Testing diodes & continuity

Do not perform continuity or diode measurements on live circuits.

  • Connect the black test lead to the "COM" jack and the red test lead to the "V Ω Hz" jack.
  • Select the 2K
  • for continuity tests.
  • Connect the test leads to the circuit/component under test.
  • Continuity: When the measured resistance is less than 30Ω a continuous beep is produced and the resistance is displayed. Should the measured resistance exceed the selected range or in case of an open circuit, the display will show “1”.
  • Diode test: Connect the red test lead to the anode; connect the black test lead to the cathode of the diode. The meter will display the approximate forward voltage drop. If the lead connection is reversed, the meter will display “1”.

range for testing diode or the 200

Measuring resistance

Page 11 of the Perel EVM892 user manual — 8. Accessories
Seite 11 · Zum Vergrößern klicken
Seite 11
  • Never perform continuity or diode measurements on a live circuit and make sure all capacitors are completely discharged.
  • Measuring diodes that are part of a circuit might produce faulty results. Consider disconnecting them from the circuit.

Do not perform capacitance measurements on live circuits. Use the included adaptor socket.

  • Connect the black test lead to the "COM" jack and the red test lead to the "mA/TEMP/CAP/hFE" jack.
  • Connect the test probes to the included adaptor socket respecting the polarity.
  • Select the appropriate "CAP" range with the FUNCTION switch. When the range is unknown, always select the highest possible range and lower to the appropriate range.
  • Place the capacitor under test in the adaptor socket, respecting the polarity in case of a polarised capacitor (the “+” of the capacitor must be inserted in the Lx jack, the “-” with the Cx jack).
  • The measured value appears on the display. Notes:
  • Never perform capacitance measurements on a live circuit and make sure all capacitors are completely discharged.
  • Should the measured capacitance exceed the selected range the display will show “1”.

Do not perform transistor measurements on live circuits. Use the included adaptor socket.

  • Connect the black test lead to the "COM" jack and the red test lead (+) to the "mA/TEMP/CAP/hFE" jack.
  • Connect the test probes to the included adaptor socket respecting the polarity.
  • Select the hFE-range with the FUNCTION switch.
  • Determine whether the transistor is of the NPNor PNP-type and locate the emitter, the base and the collector. Insert the leads into the proper holes in the included adaptor socket.
  • The display will show the approximate hFE-value (current gain). Base current 10µA, Vce 2.8V.

Do not touch any live parts with the temperature measuring probe. Use the included adaptor socket.

  • Connect the black test lead to the "COM" jack and the red test lead to the "mA/TEMP/CAP/hFE" jack.
  • Connect the test probes to the included adaptor socket respecting the polarity.
  • Select the TEMP-range with the FUNCTION switch.
  • Insert the plug of the K-thermocouple in the adaptor socket according to the indicated polarity. Note: push the temperature probe firmly into the socket.

Measuring capacitance · Transistor test (hFE) · Measuring temperature

Page 12 of the Perel EVM892 user manual — 10. Specifications
Seite 12 · Zum Vergrößern klicken
Seite 12
  • The display will show the temperature. Note: without the thermocouple in place, the display will show the ambient

temperature.

Do not perform frequency measurements in circuits with voltages > 250V.

Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers at all times during measurement.

  • Connect the black test lead to the "COM" jack and the red test lead to the "V Ω Hz" jack.
  • Select the "20KHz" range with the FUNCTION switch.
  • Connect the test leads to the circuit under test.
  • Read the measured value from the display. Notes:
  • Use a shielded cable for measuring small signals in a noisy environment (min. visible amplitude: 0.7Vpp).

10. Specifications

Ideal temperature23°C Ideal relative humidity75% Max. altitude2000m Overvoltage/installation category600V CAT. II Pollution degreePollution degree 2 Max. voltage between terminal and earth600VDC or 600Vrms AC (sine wave) Display3 ½ digit LCD, 2 to 3 readings/sec. Fuse protection200mA-range: F 0.2A/250V resettable 10A-range: ceramic F10A/250V Power supply9V-battery 6LF22 (only use nonrechargeable batteries) Ranging methodmanual Polarity indication" - " is displayed Overrange indication" 1. " is displayed automatically Battery-low indication"" is displayed Operating temperature0°C to 40°C Storage temperature-10°C to 50°C Dimensions88 x 170 x 38mm Weight340g (incl. battery)

Measuring frequencies

Page 13 of the Perel EVM892 user manual — 10. Specifications
Seite 13 · Zum Vergrößern klicken
Seite 13
Perel EVM892 — 10. Specifications diagram (page 13)
Abb. 5 · 10. Specifications

± 0.8% of rdg ± 2 digits 2V 1mV 20V 10mV 200V 100mV 600V 1V ± 1.0% of rdg ± 2 digits Input Impedance: 10MΩ for all ranges AC Voltage (V

) Range Resolution Accuracy 20V 10mV ± 0.8% of rdg ± 3 digits 200V 100mV 600V 1V ± 1.2% of rdg ± 3 digits Input Impedance: 10MΩ for all ranges Frequency Range: 40 to 400Hz DC Current (A

) Range Resolution Accuracy 20mA 10µA ± 1.2% of rdg ± 2 digits 200mA 100µA ± 1.5% of rdg ± 1 digit 10A 10mA ± 2.0% of rdg ± 5 digits Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range Max. Input Current: 10A (max.10 seconds every 15 minutes) AC Current (A

) Range Resolution Accuracy 20mA 10µA ± 1.2% of rdg ± 2 digits 200mA 100µA ± 1.8% of rdg ± 2 digits 10A 10mA ± 3.0% of rdg ± 7 digits Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range Frequency Range: 40 to 400Hz Max. Input Current: 10A (max.10 seconds every 15 minutes) Frequency Range: 40 to 400Hz Resistance

Perel EVM892 — 10. Specifications diagram (page 13)
Abb. 6 · 10. Specifications

Range Resolution Accuracy 200Ω 0.1Ω ± 0.8% of rdg ± 3 digits 2kΩ 1Ω

± 0.8% of rdg ± 2 digits 20kΩ 10Ω 200kΩ 100Ω 2MΩ 1kΩ 20MΩ 10kΩ ± 1.8% of rdg ± 2 digits Capacitance

Range Resolution Accuracy 200nF 100pF ± 4% of rdg ± 5 digits 2µF 1nF 20µF 10nF

Frage zu Perel EVM892 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Perel EVM892

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Perel EVM892 PDF-Anleitung

80 Seiten·799 KB·Messgeräte·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…