MULTIFUNCTIONELE DIGITALE MULTIMETER
MULTIMÈTRE NUMÉRIQUE MULTIFONCTIONS
MULTÍMETRO DIGITAL MULTIFUNCIÓN
MULTIFUNKTIONALES DIGITALMULTIMETER


USER MANUAL 3 GEBRUIKERSHANDLEIDING 14 NOTICE D’EMPLOI 27 MANUAL DEL USUARIO 39 BEDIENUNGSANLEITUNG 51 MANUAL DO UTILIZADOR 64




To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. The DVM892 is a 600V CAT II digital multi-meter with a 3½ digit LCD. This device is can be used to measure direct and alternating voltages, direct and alternating currents, resistance, continuity, capacity, temperature, frequency, diode and transistors (hFE). Be very careful when using this device: carelessness can lead to serious or even fatal injury. Besides the usual safety-precautions for working with electrical circuits you must follow the safety guidelines as described in this manual. Do not use this device if you do not have preliminary knowledge of circuits and test procedures. This device is not suitable for commercial or industrial use. Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
This symbol indicates: Read instructions Not reading the instructions and manual can lead to damage, injury or death.
This symbol indicates: Risk of danger/damage Risk of a hazardous condition or action that may result in damage, injury or death
This symbol indicates: Attention; important information Ignoring this information can lead to hazardous situations.
= alternating current (AC); V
= direct current(DC); V
Double insulation (class II-protection)

3. Warnings and safety instructions
Read this manual thoroughly. Familiarise yourself with the functions of the device before actually using it.
Only use the device for its intended purpose. Using the device in an unauthorized way will void the warranty. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
Keep the device away from children and unauthorised users.
Protect this device from shocks and abuse. Avoid brute force when operating.
Avoid cold, heat and large temperature fluctuations. When the unit is moved from a cold to a warm location, leave it switched off until it has reached room temperature. This to avoid condensation and measuring errors.
This is an installation category CAT II 600V measuring instrument. Never use this equipment in a higher category than indicated. Refer to §4 Overvoltage /installation category.
Pollution degree 2-device. For indoor use only. Keep this device away from rain, moisture, splashing and dripping liquids. Not for industrial use. Refer to §5 Pollution degree.
Before each use, make sure the test probes are in good condition. Always place your fingers behind the protective edges of the test probes while measuring! Never touch free terminals when the meter is connected to a circuit.
Make sure the meter is in the appropriate measuring range before connecting it to a test circuit.
Risk of electric shock during operation. Be very careful when measuring live circuits. Use extreme caution when measuring voltages higher than 60Vdc or 30Vac rms.
Do not measure circuits that may contain voltages > 600V
Do not measure current in circuits with voltages > 250V
Do not conduct resistance, diode- or continuity measurements on live circuits. For transistor tests, use the included transistor socket.
Continuity · /

When measuring currents up to 10A, max. 10s continuous measurement followed by a 15 minutes break between 2 measurements.
When carrying out measurements on a TV set or switching power circuits, always be aware that high amplitude voltage pulses at the test points might damage the meter.
Do not replace internal parts yourself. Replace damaged or lost accessories by identical ones with the same specifications. Order spare accessories e.g. test probes at your dealer.
Switch off the meter and remove test probes prior to replacing the battery or fuses.
All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.
DMMs are categorized depending on the risk and severity of transient overvoltage that might occur at the point of test. Transients are short-lived bursts of energy induced in a system, e.g. caused by lightning strike on a power line.
The existing categories according EN 61010-1 are:

This device is only suitable for measurements up to 600V in CAT II environments.
IEC 61010-1 specifies different types of pollution environments, for which different protective measures are necessary to ensure safety. Harsher environments require more protection, and the protection against the pollution which is to be found in a certain environment depends mainly on the insulation and the enclosure properties. The pollution degree rating of the DVM indicates in which environment the device may be used.
This device is only suitable for measurements in Pollution degree class 2 environments.

Refer to the illustrations on page 2 of this manual.
This push-button activates and deactivates the device. The DVM892 is also equipped with an energy-saving feature: the meter is automatically deactivated when the RANGE and FUNCTION selector has not been used for 15 minutes. The user will have to press the ON/OFF button twice to switch the device on again when the energy-saving feature has deactivated the DVM892.
RANGE and FUNCTION switch
This rotary switch is used to select the desired range or function. Always remove the test probes from the device under test before selecting a different range/function!
Do not replace internal parts yourself. Replace damaged or lost accessories by identical ones with the same specifications. Order spare accessories e.g. test probes at your dealer.
Switch off the meter and remove test leads prior to replacing the battery or fuses.
a. General maintenance: • Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol, solvents or abrasive products. b. Battery/fuse replacement
Power ON/OFF button

insert it in the slots near the top of the cover. Drive a nail in the wall and hang the meter. D: The test probes can be stored in the two provisions at the back.
Risk of electric shock during operation. Be very careful when measuring live circuits.

Limits of the meter:
Do not measure current in circuits with voltages > 250V
Current measurements: mA/TEMP/CAP/hFE jack max. 200mA; for measurements up to 10A use the 10A jack. When measuring currents up to 10A, max. 10s continuous measurement followed by a 15 minutes break between 2 measurements.
Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers at all times during measurement.

Do not perform resistance measurements on live circuits.
Testing diodes & continuity
Do not perform continuity or diode measurements on live circuits.
range for testing diode or the 200
Measuring resistance

Do not perform capacitance measurements on live circuits. Use the included adaptor socket.
Do not perform transistor measurements on live circuits. Use the included adaptor socket.
Do not touch any live parts with the temperature measuring probe. Use the included adaptor socket.
Measuring capacitance · Transistor test (hFE) · Measuring temperature

temperature.
Do not perform frequency measurements in circuits with voltages > 250V.
Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers at all times during measurement.
Measuring frequencies


± 0.8% of rdg ± 2 digits 2V 1mV 20V 10mV 200V 100mV 600V 1V ± 1.0% of rdg ± 2 digits Input Impedance: 10MΩ for all ranges AC Voltage (V
) Range Resolution Accuracy 20V 10mV ± 0.8% of rdg ± 3 digits 200V 100mV 600V 1V ± 1.2% of rdg ± 3 digits Input Impedance: 10MΩ for all ranges Frequency Range: 40 to 400Hz DC Current (A
) Range Resolution Accuracy 20mA 10µA ± 1.2% of rdg ± 2 digits 200mA 100µA ± 1.5% of rdg ± 1 digit 10A 10mA ± 2.0% of rdg ± 5 digits Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range Max. Input Current: 10A (max.10 seconds every 15 minutes) AC Current (A
) Range Resolution Accuracy 20mA 10µA ± 1.2% of rdg ± 2 digits 200mA 100µA ± 1.8% of rdg ± 2 digits 10A 10mA ± 3.0% of rdg ± 7 digits Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range Frequency Range: 40 to 400Hz Max. Input Current: 10A (max.10 seconds every 15 minutes) Frequency Range: 40 to 400Hz Resistance

Range Resolution Accuracy 200Ω 0.1Ω ± 0.8% of rdg ± 3 digits 2kΩ 1Ω
± 0.8% of rdg ± 2 digits 20kΩ 10Ω 200kΩ 100Ω 2MΩ 1kΩ 20MΩ 10kΩ ± 1.8% of rdg ± 2 digits Capacitance
Range Resolution Accuracy 200nF 100pF ± 4% of rdg ± 5 digits 2µF 1nF 20µF 10nF