1. Introduction

To all residents of the European Union Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

2. Safety Instructions

Keep this device away from children and unauthorized users. Keep this device away from rain, moisture, splashing and dripping liquids. Protect this device from shocks and abuse. Avoid brute force when operating the device. Protect the device against extreme heat and dust. There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or spare parts.

3. General Guidelines

Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.

Familiarise yourself with the functions of the device before actually using it. All modifications of the device are forbidden. Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.

V. 01 – 07/05/2015 3 ©Velleman nv

Page 2 of the Perel EEM200 user manual — 7. Operation
Seite 2 · Zum Vergrößern klicken
Seite 2

EEM200

4. Features

max / min function auto ranging: 30 ~ 130 dB auto backlight on/off resolution: 0.1 dB auto power off windscreen, battery, user manual

5. Overview

Refer to the illustrations on page 2 of this manual.

1windscreen 2microphone 3LCD display 4on-off button
5MIN/MAX button 6tripod socket 7battery compartment
MAXmaximum value MINminimum value dBCC frequency weighing dBAA frequency weighing HOLDdata hold battery level
Perel EEM200 — 5. Overview diagram (page 2)
Abb. 1 · 5. Overview

6. Battery

1. To replace the battery, make sure the device is switched off. 2. Open the battery compartment at the back using an appropriate screwdriver. 3. Take out the old battery and replace with a new and identical 9 V battery following the polarity markings inside the compartment. 4. Close the battery compartment.

7. Operation

1. Press the on-off button for 1 second to switch on the meter. 2. Briefly press the on-off button to switch on the backlight. 3. Aim the microphone to the sound source at a distance of 1 to 1.5 m. The sound level appears on the display.

V. 01 – 07/05/2015 4 ©Velleman nv

Display

Page 3 of the Perel EEM200 user manual — 9. Technical Specifications
Seite 3 · Zum Vergrößern klicken
Seite 3

EEM200

4. Briefly press the MIN/MAX button to freeze the reading on the display. Press again to unfreeze. 5. Hold the MIN/MAX button for 3 seconds to display the recorded maximum value, briefly press to display the recorded minimum value, hold pressed to exit the function. 6. Press the on-off button for 3 seconds to switch off the meter.

8. Cleaning and Maintenance

Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. DO NOT submerge the device in any liquid. Store the meter in a dry place away from humidity and vibrations. Remove the battery when the meter is to be stored for long periods of time.

9. Technical Specifications

level range30 ~ 130 dB accuracy± 1.4 dB (ref 94 dB @ 1kHz) frequency weightingA time weightingfast (125 ms) frequency range31.5 Hz to 8 kHz microphone½" electret condenser microphone LCD display3½ digits operating temperature-20° C ~ 60° C humidity10 ~ 90 % RH power supply9 V battery (incl.) auto power-off15 min. dimensions144 x 55 x 38 mm weight (with battery)± 149 g
Perel EEM200 — 9. Technical Specifications diagram (page 3)
Abb. 2 · 9. Technical Specifications

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.velleman.eu The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

V. 01 – 07/05/2015 5 ©Velleman nv

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Perel EEM200 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Perel EEM200

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Perel EEM200 PDF-Anleitung

33 Seiten·471 KB·Messgeräte·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…