Symbols The followings show the symbols used for the equipment. Be sure that you understand their meaning before use.
Symboles Nous donnons ci-dessous les symboles utilisés pour l’outil. Assurez-vous que vous en avez bien compris la significa- tion avant d’utiliser l’outil.
Symbole Die folgenden Symbole werden für die Maschine verwendet. Machen Sie sich vor der Benutzung unbedingt mit ihrer Bedeutung vertraut.
Simboli Per questo utensile vengono usati i simboli seguenti. Bisogna capire il loro significato prima di usare l’utensile.
Symbolen Voor dit gereedschap worden de volgende symbolen gebruikt. Zorg ervoor dat u de betekenis van deze symbolen begrijpt alvorens het gereedschap te gebruiken.
Símbolos A continuación se muestran los símbolos utilizados con esta herramienta. Asegúrese de que entiende su significado antes de usarla.
Símbolos O seguinte mostra os símbolos utilizados para a ferramenta. Certifique-se de que compreende o seu significado antes da utilização.
Symboler Nedenstående symboler er anvendt i forbindelse med denne maskine. Vær sikker på, at De har forstået symbolernes betydning, før maskinen anvendes.
Σύµλα Τα ακλυθα δεί νυν τα σύµλα πυ ρησιµπιύνται για τ µη άνηµα. Βεαιωθείτε τι καταλααίνετε τη σηµασία τυς πριν απ τη ρήση.

1 Compressor air output per minute 2 Nailing frequency (times/min.) 3 Adjuster 4 Too deep 5 Flush 6 Too shallow 7 Hook 8 Screw 9 Hole 10 Protrusion 11 Nose adapter
12 Latch lever 13 Door 14 Adjustfit 15 Change plate 16 Arrow 17 Nail guide 18 Feeder 19 Trigger 20 Contact element 21 Workpiece 22 Change lever 23 Thickness of workpiece
24 10 mm or more 25 C-shaped steel (Thickness 1.6 mm – 3.2 mm) 26 Nail length 27 Wood thickness 28 Concrete range 10 – 15 mm 29 Cap 30 Drain cock 31 Air filter 32 Oiler 33 Pneumatic oil
Intended use The tool is intended for the preliminary interior work such as fixing floor joists or common rafters and framing work in 2” x 4” housing.
ENB109-2 WARNING: WHEN USING THIS TOOL, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY, INCLUDING THE FOLLOWING:
WARNING: It is an employer’s responsibility to enforce the use of safety eye protection equipment by the tool operators and by other persons in the immediate working area. • For Australia and New Zealand only Always wear safety glasses and face shield to protect your eyes from dust or nail injury. The safety glasses and the face shield should conform with the require- ments of AS/NZS 1336.
Safety glasses · Face shield

- fitting transportation safety systems e.g. on vehicles
involves the use of scaffoldings, stairs, ladders, or ladder alike constructions, e.g. roof laths; - closing boxes or crates;

The hook is convenient for hanging the tool temporarily. This hook can be installed on either side of the tool. When changing the installation position, remove the screw with a screwdriver. Install the hook on another side for installation and then secure it with the screw.
SAVE THESE INSTRUCTIONS.
INSTALLATION
Selecting compressor (Fig. 1) The air compressor must comply with the requirements of EN60335-2-34. Select a compressor that has ample pressure and air output to assure cost-efficient operation. The graph shows the relation between nailing frequency, applicable pressure and compressor air output. Thus, for example, if nailing takes place at a rate of approximately 40 times per minute at a compression of 1.77 MPa (17.7 bar), a compressor with an air output over 50 liters/minute is required. Pressure regulators must be used to limit air pressure to the rated pressure of the tool where air supply pressure exceeds the tool’s rated pressure. Failure to do so may result in serious injury to tool operator or persons in the vicinity.
If you like to protect the surface of workpiece, attach the nose adapter of contact element. When nailing workpieces with easily-marred surfaces, use the nose adapter. To attach the nose adapter to the contact element, press it onto the contact element until the protrusion in three places inside the nose adapter fit in three holes in the contact element.
Selecting air hose (Fig. 2) Use a high pressure resistant air hose. Use an air hose as large and as short as possible to assure continuous, efficient nailing operation.
Disconnect the air hose from the tool. Select nails suitable for your work. Depress the latch lever and open the door and magazine cap. (Fig. 9) Select nails suitable for your work. Depress the latch lever and open the magazine cap. Lift and turn the coil support plate so that the arrow with nail size indicated on the coil support plate will point to the corresponding graduation increment marked on the magazine. If the tool is operated with the coil support plate set to the wrong step, poor nail feed or malfunction of the tool may result. (Fig. 10) Place the nail coil over the coil support plate. Uncoil enough nails to reach the nail guide. Place the first nail in the feeder and the second nail in the feed claw. Place other uncoiled nails on feeder body. Close the magazine cap slowly until it lock after checking to see that the nail coil is set properly in the magazine. (Fig. 11)
Lubrication To insure maximum performance, install an air set (oiler, regulator, air filter) as close as possible to the tool. Adjust the oiler so that one drop of oil will be provided for every 30 nails. (Fig. 3) When an air set is not used, oil the tool with pneumatic tool oil by placing 2 (two) or 3 (three) drops into the air fit- ting. This should be done before and after use. For proper lubrication, the tool must be fired a couple of times after pneumatic tool oil is introduced. (Fig. 4)
Connecting air hose Slip the air socket of the air hose onto the air fitting on the nailer. Be sure that the air socket locks firmly into position when installed onto the air fitting. A hose cou- pling must be installed on or near the tool in such a way that the pressure reservoir will discharge at the time the air supply coupling is disconnected.
If nails are driven too deep, turn the adjuster clockwise. If nails are driven too shallow, turn the adjuster counter- clockwise. The adjustable range is 10 mm. (One full turn allows 0.8 mm adjustment.)

CAUTION: • However when the tool is set to the “Intermittent Nail- ing” mode, WITH THE TRIGGER HELD IN A HALF- PULLED POSITION, an unexpected nailing could occur, if contact element is allowed to re-contact against the workpiece or the other surface under the influence of recoil. In order to avoid this unexpected nailing, perform as follows; A. Do not place the contact element against the work-
Choose and use nails so that the penetration amount into concrete ranges 10 mm – 15 mm by referring to the table below.
piece with excessive force. B. Pull the trigger fully and hold it on for 1 – 2 seconds
Tear off the output sheet in the direction of the arrow when using the sheet collated nails.
Choose and use nails more than 10 mm longer than total thickness of all workpiece to be fastened by referring to the table below.
When the nailer becomes jammed, do as follows: Open the magazine cap and remove the nail coil. Insert a small rod or the like into the ejection port and tap it with a hammer to drive out the nail jamming from the ejection port. Reset the nail coil and close the magazine cap.
Drain tool Remove the hose from the tool. Place the tool so that the air fitting faces down to the floor. Drain as much as possi- ble.
Cleaning of tool Iron dust that adhere to the magnet can be blown off by using an air duster.
Cap (Fig. 20) When not in use, disconnect the hose. Then cap the air fitting with the cap.
Storage When not in use, the nailer should be stored in a warm and dry place.

Maintenance of compressor, air set and air hose After operation, always drain the compressor tank and the air filter. If moisture is allowed to enter the tool, it may result in poor performance and possible tool failure. (Fig. 21 & 22) Check regularly to see if there is sufficient pneumatic oil in the oiler of the air set. Failure to maintain sufficient lubrication will cause O-rings to wear quickly. (Fig. 23) Keep the air hose away from heat (over 60°C, over 140°F), away from chemicals (thinner, strong acids or alkalis). Also, route the hose away from obstacles which it may become dangerously caught on during operation. Hoses must also be directed away from sharp edges and areas which may lead to damage or abrasion to the hose. (Fig. 24)
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be per- formed by Makita Authorized Service Centers, always using Makita replacement parts.
If you need any assistance for more details regarding these accessories, ask your local Makita service center.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.