Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. e) When operating a power tool outdoors, use an extension
cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. f) If operating a power tool in a damp location is unavoidable,
Save all warnings and instructions for future reference. The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool. 1) Work area safety a) Keep work area clean and well lit. Cluttered or dark areas invite accidents. b) Do not operate power tools in explosive atmospheres,
use a residual current device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.
sense when operating a power tool. Do not use a power tool while you are tired or under the infl uence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury. b) Use personal protective equipment. Always wear eye
such as in the presence of fl ammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes. c) Keep children and bystanders away while operating a
power tool. Distractions can cause you to lose control.
protection. Protective equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. c) Prevent unintentional starting. Ensure the switch is in the
off -position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your fi nger on the switch or energising power tools that have the switch on invites accidents. d) Remove any adjusting key or wrench before turning the
such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded. c) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. d) Do not abuse the cord. Never use the cord for carrying,
power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. e) Do not overreach. Keep proper footing and balance at all
times. This enables better control of the power tool in unexpected situations.
pulling or unplugging the power tool.

f) Dress properly. Do not wear loose clothing or jewellery.
g) Use the power tool, accessories and tool bits etc. in
Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts. g) If devices are provided for the connection of dust
accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations diff erent from those intended could result in a hazardous situation.
extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust related hazards.
packs. Use of any other battery packs may create a risk of injury and fi re. b) When battery pack is not in use, keep it away from other metal
for your application. The correct power tool will do the job better and safer at the rate for which it was designed. b) Do not use the power tool if the switch does not turn it on
objects like paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fi re. c) Under abusive conditions, liquid may be ejected from
and off . Any power tool that cannot be controlled with the switch is dangerous and must be repaired. c) Disconnect the plug from the power source and/or the
the battery; avoid contact. If contact accidentally occurs, fl ush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
battery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally. d) Store idle power tools out of the reach of children and do
using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users. e) Maintain power tools. Check for misalignment or binding
PRECAUTION Keep children and infi rm persons away. When not in use, tools should be stored out of reach of children and infi rm persons.
of moving parts, breakage of parts and any other condition that may aff ect the power toolsʼ operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools. f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.

○ Where it will be exposed to direct sunlight or high temperature such as near a heating appliance ○ On the dashboard, in the trunk, on the luggage platform or in direct sunlight inside a vehicle with the windows closed ○ Where it will be exposed to magnetism, vibration, dust, moisture or humidity 4. Do not use the instrument if there is condensation on it. Doing so may result in loss of accuracy or breakdown. 5. Do not use in a faulty condition. Stop using the instrument immediately and contact the dealer where it was purchased or your nearest Hitachi Koki power tool service centre. 6. Do not subject the instrument to strong impact by dropping it or knocking it over. If dropped or knocked over, check the accuracy or send it for repair. 7. Do not expose the instrument to rain or water. The performance or service life will be adversely aff ected and malfunction may result. 8. Turn the power off before moving the instrument. 9. Do not touch the laser aperture or receiver lens. Doing so may result in loss of accuracy. 10. Place the instrument in the soft case for carrying. Vibration or impact may result in loss of accuracy or breakdown. 11. Store the instrument in the soft case. Humidity or dust may cause breakdown. 12. Remove the battery when not in use. Leakage of battery fl uid may cause breakdown. 13. User safety training The user should have adequate understanding of the properties, harmful eff ects, etc. of lasers. 14. Perform measuring in a safe place.
WARNING 1. Do not look directly at the laser beam through an optical instrument. Looking at the laser beam through a telescope, binoculars or magnifying glass may damage your eyes. 2. If you feel the instrument is not working normally, do not under any circumstances use it. If the laser is too powerful or too weak, send the instrument for repair. 3. Do not look directly into the laser beam. Looking directly into the laser beam may damage your eyes. 4. Avoid using the laser at eye level. If the laser beam hits your eyes directly, it may damage your eyes. 5. Do not stand in the path of the laser beam. 6. Do not under any circumstances disassemble or modify the instrument. In the event of breakdown or repair, contact the dealer where you purchased the instrument or your nearest Hitachi Koki power tool service centre. 7. Do not place any refl ective object in the path of the laser beam. If the laser beam is refl ected into your eyes, it may damage your eyes. 8. If you suspect any injury due to the laser beam, consult a doctor immediately. 9. Do not point the laser beam at anyone. 10. Do not allow the instrument to be used by a child.
CAUTION 1. Be sure to check the measuring accuracy before and after use. Using the instrument in a faulty condition may result in error. 2. Use the instrument in an ambient temperature of 0°C to 40°C. Use in any other environment may result in loss of accuracy or failure to emit the laser beam. 3. Do not leave the instrument in the following places. Doing so may result in loss of accuracy or breakdown.
Disclaimer ○ Observe all safety warnings and instructions in this manual when using the instrument. Hitachi Koki assumes no responsibility for damages (including losses due to interruption of business) arising from use of the product other than in accordance with the instructions in the manual.

○ Be sure to check the accuracy before and after use. Similarly, check the accuracy after the instrument has been subjected to impact by being knocked over or dropped. Hitachi Koki assumes no responsibility for damages arising from error due to non- performance of the accuracy check.
○ Hitachi Koki assumes no responsibility for damages arising from use of the laser meter other than for the intended purpose. ○ Hitachi Koki assumes no responsibility for damages arising from fi re, earthquakes, fl oods, lightning and other disasters.


*1 The measurable range may vary depending on the characteristics of the laser beam refl ected from the target surface and the surrounding brightness. *2 Laser class based on EN60825-1 *3 The measuring accuracy may vary depending on the characteristics of the laser beam refl ected from the target surface and the surrounding brightness. *4 The measuring time may vary depending on the characteristics of the laser beam refl ected from the target surface and the surrounding brightness. *5 Water splashes and dust have no harmful eff ect. *6 Battery life may be reduced depending on usage environment and type of battery. *7 Time until the power turns off automatically when left unoperated.

HOW TO USE THE DIGITAL LASER METER
○ Soft case 1 ○ 9 V alkaline battery 1 ○ Strap 1 ○ Label 1 Standard accessories are subject to change without notice.
Optional accessories are subject to change without notice.
○ Measuring distance, area, volume and side length at building sites
The battery is not installed in the instrument when it leaves the factory. Follow the instructions below and insert the battery before use. 1. Press the hook of the battery cover in the direction of the arrow and remove the battery cover. (a) 2. Connect a new battery, paying attention to the correct polarity. (b) 3. Insert the battery with the terminal at the bottom. Match the hook to the hole in the main unit and press the battery cover shut. (c)
A label in English is attached to the instrument when it leaves the factory. Select a supplied label in the required language and attach it to the label frame on the instrument.
Operation · ○ Target plate

Examples of measuring using diff erent reference points 1 Measuring using front reference point (Fig. 7) Place the front (reference point) of the instrument against the measuring surface. 2 Measuring using rear reference point (Fig. 8) Place the rear (reference point) of the instrument against the measuring surface. 3 Measuring using the W1/4 socket hole (for the tripod) as the reference point (Fig. 9) Use the center of the socket hole for attaching the tripod as the reference point.
○ The length of time after the power is turned on until the instrument is ready to measure may vary depending on the usage environment. ○ If an error occurs while measuring, remedy the cause before resuming measuring.
Measuring distance (Fig. 2, 6) 1 Select distance mode. (See “Selecting a measuring mode”) 2 Press the measure button and aim the laser beam at the target. The status is indicated on the display. 3 Press the measure button again to stop measuring. A beep sounds and the measurement is indicated on the display. When measuring is fi nished, the laser goes off . 4 To continue measuring distance, repeat steps 2 and 3. The side button on the side of the instrument has the same function as the measure button on the operation panel. For convenient operation in narrow spaces, the instrument can be placed in a vertical position.
NOTE ○ Check that there is nothing obstructing measurement by the laser. ○ Do not move the instrument during measuring (except during continuous measurement). ○ The center of the laser beam is measured. The same applies when the beam is aimed diagonally at the target. ○ The measuring range may vary depending on the characteristics of the laser beam refl ected from the target surface or the surrounding brightness. To measure quickly and accurately outdoors in bright sunlight, use a target plate (sold separately) or put the target in the shade. ○ Measuring errors may occur with transparent surfaces (such as glass or water) or mirror surfaces, as well as in the case of surfaces with holes in, uneven surfaces, diff erent temperatures and indirectly refl ected light. ○ If the power is turned on and no button is pressed, the power will turn off automatically after approximately 3 minutes. Press the power button again to resume operation. ○ If the instrument is used and then left with no button pressed, the laser will turn off after approximately 30 seconds. Press the measure button again to resume operation.
Continuous measurement Use continuous measurement to set the desired position from the target. 1 Select continuous measurement mode. (See “Selecting a measuring mode”) 2 Press the measure button and aim the laser beam at the target. 3 Move the instrument until the desired measurement is indicated on the display. 4 Press the measure button again to fi nish continuous measurement. The last measurement is indicated on the display.
Measurements are successively indicated on the display with a beep sound every 0.5 to 3 seconds. The previous measurement is deleted when the next measurement is taken. In continuous measurement mode, the power does not turn off automatically. Be sure to press the power button after operation to end continuous measurement.

Measuring area (Fig. 11) If you measure the length and the width, the area is automatically calculated. 1 Select area mode. (See “Selecting a measuring mode”) 2 Measure the length. ○ Press the measure button and aim the laser at the target length. ○ Press the measure button again to fi nish measuring. A beep sounds and the length measurement is indicated on the display. The laser does not go off at this time. 3 Measure the width. ○ Press the measure button and aim the laser at the target width. ○ Press the measure button again to fi nish measuring. A beep sounds and the width measurement and calculated area are indicated on the display.
○ Press the measure button again to fi nish measuring. A beep sounds and the height measurement and calculated volume are indicated on the display.
Before m3
3.083 m 3.083 m →Length measurement →Length measurement
6.289 m2
2.040 m →Area calculation result →Width measurement
5.333 m3
0.848 m → Volume calculation
Measuring sides (Pythagorean theorem) If you measure the two sides of a right triangle, the length of the third side is calculated automatically. Use this mode when you cannot measure the distance because there is an obstacle or there is no elevated target surface. To obtain side C (Fig. 13) 1 Select side mode. (See “Selecting a measuring mode”) 2 Measure the length of side A. Follow the instructions for measuring the length in area mode and measure side A. 3 Measure side B. ○ Follow the instructions for measuring the length of side A and measure the length of side B. ○ When you have fi nished measuring, a beep sounds and the measured length of side B and calculated result of side C are indicated on the display.
Before measuring m2
3.083 m 3.083 m →Length measurement →Length measurement
6.289 m2
2.040 m →Area calculation result →Width measurement
Measuring volume (Fig. 12) If you measure the length, width and height, the volume is automatically calculated. 1 Select volume mode. (See “Selecting a measuring mode”) 2 Measure the length. Follow the instructions for measuring the length in area mode. 3 Measure the width. Follow the instructions for measuring the width in area mode. 4 Measure the height. ○ Press the measure button and aim the laser at the target height.

Adding (Fig. 2, 3) A new measurement can be added to a previous measurement already stored in the memory. Press the add button when a measurement is displayed. The calculated result and [+] next to it blink 3 times in the top row on the display. Measurements in diff erent units (m, m2, m3) cannot be added. Subtracting (Fig. 2, 3) A new measurement can be subtracted from a measurement already stored in the memory. Press the subtract button when a measurement is displayed. The calculated result and [–] next to it blink 3 times in the top row on the display. Measurements in diff erent units (m, m2, m3) cannot be subtracted.
Before measuring m m
After measuring side A
1.862 m 1.862 m →Side A measurement →Side A measurement
After measuring side B
5.039 m 5.372 m → Calculated result of
side C →Side B measurement
Deleting a measurement (Fig. 2) Press the power on/off (clear) button on the operation panel to delete a measurement. Turning on the display light (Fig. 2) Press the display light button to turn the green backlight on and off . The backlight goes off automatically after approximately 8 seconds if no button is pressed. The backlight cannot be turned on and off while measuring. Muting the beep (Fig. 2) Press and hold the memory button on the operation panel for at least 2 seconds to turn the beep on and off . Changing the unit (Fig. 2) Press the unit select button on the operation panel to change the measurement unit. Turning off the power (Fig. 2) Press and hold the power on/off (clear) button on the operation panel for at least 2 seconds to turn the power off .
Deleting a saved measurement (Fig. 2, 3) 1 Press the memory button to move the measurement indicated on the display to the top row. 2 Press the power on/off (clear) button to delete the memory.
If the accuracy is found to be faulty, contact the dealer for repairs.
Saving (Fig. 2, 3) Press the memory button to save the measurement indicated on the display. [=] appears in the top row of the display and the saved measurement is indicated next to it. The saved measurement is not deleted when the power is turned off and it is indicated in the top row of the display the next time the power is turned on.
Display Content

2 Accuracy is normal if the variation in the measurements is within 3 mm. Measuring accuracy may vary depending on the characteristics of the laser beam refl ected from the target surface or the surrounding brightness. Measure the target surface under the following conditions. ○ Dark place away from direct sunlight ○ Smooth surface ○ Not too strongly refl ecting surface (mirror, etc.) ○ White or gray wall ○ Free from steam, mirage or dust
○ If the instrument is not to be used for a long period, remove the battery. ○ Avoid storing the unused instrument or accessories in the following places. Store in a safe, dry place.
Causes of error and remedies
Error code Cause Remedy
201 Outside measuring range
Use within measuring range.
Dispose of the instrument appropriately by a method specifi ed by the local government of the area. Disposing of the instrument inappropriately may result in the following problems. ○ Burning plastic components generates noxious fumes that may present a danger to public health. ○ If the battery is damaged or is heated and explodes, it may lead to poisoning, burns, corrosion or fi re or cause environmental pollution. ○ Disposing of the instrument irresponsibly may lead to someone with no knowledge of the product using it in violation of the regulations. This may lead to serious injury not only to yourself but to others, as well as causing environmental pollution. EU only: Do not dispose of the instrument with household garbage.
202 Refl ected signal is too weak
Measure target surface in good condition.
203 Exceeded display range
Press on/off button to reset.
204 Calculation error (Pythagorean theorem)
Measure in correct order.
205 Exhausted battery Replace with new battery.
206 Temperature too high Use in range of 0oC to 40oC.
207 Temperature too low Use in range of 0oC to 40oC.
208 Surroundings too bright
Measure away from strong light (direct sunlight, etc.).
Observe EU Directive 2002/96/EC (Waste electrical and electronic equipment) and the rules of the respective country. Dispose of the instrument by sorting for environment-friendly recycling. Disposal of battery Do not dispose of the used battery with household garbage or throw into fi re or water. Dispose of it in a legally defi ned and environmentally friendly manner.
○ After use, be sure to turn off the power and store the instrument in the provided case.

This product is a high-precision instrument. If it does not operate normally, do not attempt to repair it yourself. Contact the dealer.
We guarantee Hitachi Power Tools in accordance with statutory/country specifi c regulation. This guarantee does not cover defects or damage due to misuse, abuse, or normal wear and tear. In case of complaint, please send the Power Tool, undismantled, with the GUARANTEE CERTIFICATE found at the end of this handling instruction, to a Hitachi Authorized Service Center.
Was die auf dem Display angezeigten Fehlercodes bedeuten und wie man sie behebt.
| Code | Bedeutung | Lösung | |
|---|---|---|---|
| 201 | Outside measuring range | Use within measuring range. | p.10 |
| 202 | Refl ected signal is too weak | Measure target surface in good condition. | p.10 |
| 203 | Exceeded display range | Press on/off button to reset. | p.10 |
| 204 | Calculation error (Pythagorean theorem) | Measure in correct order. | p.10 |
| 205 | Exhausted battery | Replace with new battery. | p.10 |
| 206 | Temperature too high | Use in range of 0oC to 40oC. | p.10 |
| 207 | Temperature too low | Use in range of 0oC to 40oC. | p.10 |
| 208 | Surroundings too bright | Measure away from strong light (direct sunlight, etc.). | p.10 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.