DE
Hitachi logo
Offizielle Bedienungsanleitung

Hitachi EC1433H

60 Seiten·3.4 MB·Kompressor·PDF·ENJA
Hitachi EC1433H
Inhaltsverzeichnis 12 Abschnitte EC1433H · DESCRIPTION OF FUNCTIONS OF KEY COMPONENTS · SAFETY WARNINGS · WARNING · … AnzeigenAusblenden
Page 1 of the Hitachi EC1433H user manual — EC1433H
Seite 1 · Zum Vergrößern klicken
Seite 1

High-Pressure Air Compressor Hochdruck Luftkompressor Compresseur d'air à haute pression Compressore d'aria ad alta pressione Persluchtcompressor Compresor de aire a alta presión Compressor de ar a alta pressão

EC1433H

Hitachi EC1433H — EC1433H diagram (page 1)
Abb. 1

Read through carefully and understand these instructions before use. Diese Anleitung vor Benutzung des Werkzeugs sorgfältig durchlesen und verstehen. Lire soigneusement et bien assimiler ces instructions avant usage. Prima dell’uso leggere attentamente e comprendere queste instruzioni. Deze gebruiksaanwijzing s.v.p. voor gebruik zorgvuldig doorlezen. Leer cuidadosamente y comprender estas instrucciones antes del uso. Antes de usar, leia com cuidado para assimilar estas instruções.

Handling instructions Bedienungsanleitung Mode d’emploi Istruzioni per l’uso Gebruiksaanwijzing Instrucciones de manejo Instruções de uso

Page 2 of the Hitachi EC1433H user manual — EC1433H
Seite 2 · Zum Vergrößern klicken
Seite 2
Hitachi EC1433H — EC1433H diagram (page 2)
Abb. 2
Page 3 of the Hitachi EC1433H user manual — EC1433H
Seite 3 · Zum Vergrößern klicken
Seite 3
EnglishDeutschFrançaisItaliano 1Drain leverAblasshebelLevier de purgeLeva di scarico 2Pressure-reduction valve adjustment handle (L)DruckminderventilEinstellhebel (L)Levier de réglage du détendeur (L)Regolatore valvola di riduzione della pressione (L) 3Pressure-reduction valve adjustment handle (H)DruckminderventilEinstellhebel (H)Levier de réglage du détendeur (H)Regolatore valvola di riduzione della pressione (H) 4Pressure gaugeManometerJauge de pressionManometro 5Air socketLuftanschlussRaccord d’airAttacco aria 6Air hoseLuftschlauchTuyau d’airTubo dell’aria
NederlandsEspañolPortuguês 1AftaphendelPalanca de drenajeAlavanca de drenagem 2Instelhendel van reduceerventiel (L)Asa de ajuste de la válvula reductora de presión (L)Manípulo de ajuste da válvula de redução da pressão (L) 3Instelhendel van reduceerventiel (H)Asa de ajuste de la válvula reductora de presión (H)Manípulo de ajuste da válvula de redução da pressão (H) 4DrukmeterManómetroManómetro 5LuchtaansluitingManguito de aierTomada de ar 6LuchtslangManguera de aireMangueira de ar
Page 4 of the Hitachi EC1433H user manual — EC1433H
Seite 4 · Zum Vergrößern klicken
Seite 4
Symbols WARNING The following show symbols used for the machine. Be sure that you understand their meaning before use.Symbole WARNUNG Die folgenden Symbole werden für diese Maschine verwendet. Achten Sie darauf, diese vor der Verwendung zu verstehen.Symboles AVERTISSEMENT Les symboles suivants sont utilisés pour l’outil. Bien se familiariser avec leur signifi cation avant d’utiliser l’outil.Simboli AVVERTENZA Di seguito mostriamo i simboli usati per la macchina. Assicurarsi di comprenderne il signifi cato prima dell’uso. Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fi re and/or serious injury.Lesen Sie sämtliche Sicherheitshinweise und Anweisungen durch. Wenn die Warnungen und Anweisungen nicht befolgt werden, kann es zu Stromschlag, Brand und/oder ernsthaften Verletzungen kommen.Lire tous les avertissements de sécurité et toutes les instructions. Tout manquement à observer ces avertissements et instructions peut engendrer des chocs électriques, des incendies et/ou des blessures graves.Leggere tutti gli avvertimenti di sicurezza e tutte le istruzioni. La mancata osservanza degli avvertimenti e delle istruzioni potrebbe essere causa di scosse elettriche, incendi e/o gravi lesioni. Always wear eye protection.Tragen Sie immer einen Augenschutz.Toujours porter des verres de protection.Indossate sempre le protezioni oculari. Only for EU countries Do not dispose of electric tools together with household waste material! In observance of European Directive 2002/96/EC on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.Nur für EU-Länder Werfen Sie Elektrowerkzeuge nicht in den Hausmüll! Gemäss Europäischer Richtlinie 2002/96/EG über Elektround ElektronikAltgeräte und Umsetzung in nationales Recht müssen verbrauchte Elektrowerkzeuge getrennt gesammelt und einer umweltgerechten Wiederververtung zugeführt werden.Pour les pays européens uniquement Ne pas jeter les appareils électriques dans les ordures ménagères! Conformément à la directive européenne 2002/96/EG relative aux déchets d’équipements électriques ou électroniques (DEEE), et à sa transposition dans la législation nationale, les appareils électriques doivent être collectés à part et être soumis à un recyclage respectueux de l’environnement.Solo per Paesi UE Non gettare le apparecchiature elettriche tra i rifi uti domestici. Secondo la Direttiva Europea 2002/96/CE sui rifi uti di apparecchiature elettriche ed elettroniche e la sua attuazione in conformità alle norme nazionali, le apparecchiature elettriche esauste devono essere raccolte separatamente, al fi ne di essere reimpiegate in modo ecocompatibile. Symbolen WAARSCHUWING Hieronder staan symbolen afgebeeld die van toepassing zijn op deze machine. U moet de betekenis hiervan begrijpen voor gebruik.Símbolos ADVERTENCIA A continuación se muestran los símbolos usados para la máquina. Asegúrese de comprender su signifi cado antes del uso.Símbolos AVISO A seguir aparecem os símbolos utilizados pela máquina. Assimile bem seus signifi cados antes do uso. Lees alle waarschuwingen en instructies aandachtig door. Nalating om de waarschuwingen en instructies op te volgen kan in een elektrische schok, brand en/of ernstig letsel resulteren.Lea todas las instrucciones y advertencias de seguridad. Si no se siguen las advertencias e instrucciones, podría producirse una descarga eléctrica, un incendio y/o daños graves.Leia todas as instruções e avisos de segurança. Se não seguir todas as instruções e os avisos, pode provocar um choque eléctrico, incêndio e/ou ferimentos graves. Draag altijd oogbescherming.Utilice siempre una protección ocular.Utilize sempre protecção para os olhos. Alleen voor EU-landen Geef elektrisch gereedschap niet met het huisvuil mee! Volgens de Europese richtlijn 2002/96/EG inzake oude elektrische en elektronische apparaten en de toepassing daarvan binnen de nationale wetgeving, dient gebruikt elektrisch gereedschap gescheiden te worden ingezameld en te worden afgevoerd naar een recycle bedrijf dat voldoet aan de geldende milieu-eisen.Sólo para países de la Unión Europea ¡No deseche los aparatos eléctricos junto con los residuos domésticos! De conformidad con la Directiva Europea 2002/96/CE sobre residuos de aparatos eléctricos y electrónicos y su aplicación de acuerdo con la legislación nacional, las herramientas eléctricas cuya vida útil haya llegado a su fi n se deberán recoger por separado y trasladar a una planta de reciclaje que cumpla con las exigencias ecológicas.Apenas para países da UE Não deite ferramentas eléctricas no lixo doméstico! De acordo com a directiva europeia 2002/96/CE sobre ferramentas eléctricas e electrónicas usadas e a transposição para as leis nacionais, as ferramentas eléctricas usadas devem ser recolhidas em separado e encaminhadas a uma instalação de reciclagem dos materiais ecológica.
Page 5 of the Hitachi EC1433H user manual — PRECAUTIONS ON USING THE COMPRESSOR
Seite 5 · Zum Vergrößern klicken
Seite 5

DESCRIPTION OF FUNCTIONS OF KEY COMPONENTS

Power switchTurns on or off the power supply Pressure-reduction valve adjustment handle (H) (RED cap)Intended for exclusive use with the super nailer. It adjusts the operating pressure of the Hitachi high pressure tool. Pressure-reduction valve adjustment handle (L) (GRAY cap)Adjusts the pressure supplied to the general-purpose nailers and pneumatic tools (operating air pressure 8 bar (116 psi) maximum). Pressure gauge in the tankIndicates pressure in the tank. The pressure increases up to 32.5 bar. (471.4 psi) Pressure gauge for indicating the set reduction valve pressure (2 gauges)It indicates the set pressure on the pressure-reduction valves (H) and (L). (25 bar (362.6 psi) maximum on the H side and 8 bar (116 psi) maximum on the L side.) High pressure air socket (for Hitachi high pressure tools)It connects the Hitachi high pressure air hose for the Hitachi high pressure tools. Regular pressure air socket (for regular pressure tools)It connects the air hose for the regular-pressure nailers. Drain leverIt drains compressed air and water, Drain once when the work is fi nished or more a day. Power plugIt is usable with a triode ground outlet.

2. Never operate without all guards in place Never operate the compressor without all guards or safety features in place and in proper working order. If maintenance or servicing requires the removal of a guard or safety features, be sure to replace the guards or safety feature before resuming operation of the compressor. 3. Always wear eye protection Always wear safety goggles or equivalent eye protection. Compressed air must never be aimed at anyone or any part of the body. Be sure to wear protective gear including the sound-proofi ng and protective garment, crash cap and safety footwear suited for the given working environment. 4. Protect yourself against electric shock Prevent body contact with grounded surfaces such as pipes, radiators, ranges and refrigeration enclosures. Never operate the compressor in damp or wet locations. 5. Disconnect the compressor Always disconnect the compressor from the power plug and remove the compressed air from the air tank before servicing, inspecting, maintaining, cleaning, replacing or checking any parts. 6. Avoid unintentional starting Do not carry the compressor while it is connected to its power source or when the air tank is fi lled with compressed air. Be sure the knob of the pressure switch in the "OFF" position before connecting the compressor to its power source. 7. Store compressor properly When not in use, the compressor should be stored in dry place. Keep out of reach of children. Lock-out the storage area. 8. Keep work area clean Cluttered areas invite injuries. Clear all work areas of unnecessary tools, debris, furniture, etc. 9. Keep children away Do not let visitors contact compressor extension cord. All visitors should be kept safely away from work area. Keep out of reach of children.

SAFETY WARNINGS

WARNING

To avoid severe personal injury or property damage.Before using the tool, read carefully and understand the following "SAFETY WARNINGS": Failure to follow warnings could result in death or serious injury.

PRECAUTIONS ON USING THE COMPRESSOR

Important information Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures. Basic safety precautions are outlines in the "SAFETY" section of this Instruction Manual and in the sections which contain the operation and maintenance instructions. Hazards that must be avoided to prevent bodily injury or machine damage are identifi ed by WARNINGS on the compressor and in this Instruction Manual. Never use this compressor in a manner that has not been specifi cally recommended by manufacturer, unless you fi rst confi rm that the planned use will be safe for you and others.

Death or serious bodily injury could result from improper or unsafe use of compressor, to avoid these risks, follow these basic safety instructions. High pressure compressor provides both high pressure and regular pressure air. For usage of high pressure air, high pressure compressor is designed only for Hitachi high pressure nailers and high pressure air hose. Unspecifi ed usage will cause serious accidents. 1. Never touch moving parts Never place your hands, fi ngers or body parts near the compressor's moving parts.

(Original instructions)

Page 6 of the Hitachi EC1433H user manual — DESCRIPTION OF FUNCTIONS OF KEY COMPONENTS
Seite 6 · Zum Vergrößern klicken
Seite 6

10. Dress properly Do not wear loose clothing or jewelry. They can be caught in moving parts. Wear protective hair covering to contain long hair. 11. Don't abuse power cord Never yank it to disconnect from receptacle. Keep power cord from heat, oil and sharp edges. 12. Maintain compressor with care Follow instructions for lubricating. Inspect cords periodically and if damaged, have repaired by authorized service facility. 13. Use a safe extension cord In order to prevent an electric shock, use a 3-core extension cord with a 3-pole earthing plug and a 3-core earthing plug socket. Make sure that the extension cord is in the good working condition. If the cord is damaged, replace or repair it. The cord should have a suffi cient capacity for the current running to the product. The cord of an insuffi cient capacity will cause a voltage drop or an electric power loss, resulting in overheating. The following table shows the cord size used depending on the cord length. If the compressor is to be used outdoors, use an exclusive extension cord.

19. Operate compressor at the rated voltage Operate the compressor at voltages specifi ed on their nameplates. If using the compressor at a higher voltage than the rated voltage, it will result in abnormally fast motor revolution and may damage the unit and burn out the motor. 20. Never use a compressor which is defective or operating abnormally If the compressor appears to be operating unusually, making strange noises, or otherwise appears defective, stop using it immediately and arrange for repairs by an authorized service facility. 21. Do not wipe plastic parts with solvent Solvent such as gasoline, thinner, benzine, carbon tetrachloride, and alcohol may damage and crack plastic parts. Do not wipe them with such solvents. Wipe plastic parts with a soft cloth lightly dampened with mild detergent and dry thoroughly. 22. Use only genuine replacement parts Replacement parts not original may void your warranty and can lead to malfunction and resulting injuries. Genuine parts are available from your dealer. 23. Do not modify the compressor Do not modify the compressor. Always contact the authorized service facility any repairs. Unauthorized modifi cation may not only impair the compressor performance but may also result in accident or injury to repair personnel who do not have the required knowledge and technical expertise to perform the repair operations correctly. 24. Turn off the switch when the compressor is not used When the compressor is not used, turn the switch OFF, disconnect the plug from the power source and open the drain cock to discharge the compressed air from the air tank. 25. Never touch the surface of the high-temperature section In order to prevent a burn, do not touch the piping, head, cylinder, motor and inverter case. 26. Do not direct air stream at body Risk of injury, do not direct compressed air at persons or animals. 27. Drain tank Drain tank daily or after 4 hours of use. Open drain cock and tilt compressor to empty accumulated water. 28. Do not stop compressor by pulling out the plug Use the " ON/OFF " switch. 29. Make sure the compressor outlet pressure is set lower than the maximum operating pressure of the tool. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The reducer outlet pressure must never exceed the maximum pressure rating. 30. Whenever using the high pressure side of the Hitachi high pressure compressor, the genuine parts for the Hitachi high pressure tools, high pressare air hose and compressor must be used. 31. Replacement parts When servicing, use only Hitachi genuine parts. Repair should be conducted only by authorized service facility. 32. Never use a transformer for the power supply of this compressor. Using a transformer to increase the voltage will cause a failure or burnout. (If a transformer is used, operation of the machine will stop.)

Table 1 Section valid for a max length of 20m (65')

CompressorHPW230 V (mm2) EC1433H1.279502.5

WARNING Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical cord or extension cord. Inspect all electrical cords regularly. Never use in near water or in any environment where electric shock is possible. 14. Stay alert Watch what you are doing. Use common sense. Do not operate compressor when you are tired. Compressor should never be used by you if you are under the infl uence of alcohol, drugs or medication that makes you drowsy. 15. Check damaged parts and air leak Before further use of the compressor, a guard or other part which is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions that may aff ected its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service facility unless otherwise indicated elsewhere in this Instruction Manual. Have defective pressure controllers replaced by authorized service facility. Do not use compressor if switch does not turn it on and off . 16. Operate compressor correctly Operate the compressor according to the instructions provided herein. Never allow the compressor to be operated by children, individuals unfamiliar with its operation or unauthorized personal. 17. Keep all screws, bolts and covers tightly in place Keep all screws, bolts, and plates tightly mounted. Check their conditions periodically. 18. Keep motor air vent clean The motor air vent must be kept clean so that air can freely fl ow at all times. Check for dust build-up frequently.

Page 7 of the Hitachi EC1433H user manual — INSTRUCTIONS FOR OPERATION
Seite 7 · Zum Vergrößern klicken
Seite 7

33. Never connect the compressor to an engine generator or direct-current power supply The compressor will break or be damaged from burning. 34. This compressor is for indoor use. Do not install the compressor in any place exposed to rain or splashed water, high-humidity place or high- temperature place (Fig. 1) If used in the wet condition, it could produce an electric shock or be short-circuited, resulting in ignition. Use it under the environmental conditions provided by its specifi cations. 35. Do not operate the tool near a fl ammable substance Never operate the tool near a fl ammable substance (e.g., thinner, gasoline, etc.). (Fig. 2) Volatile fumes from these substances could be drawn into the compressor and compressed together with the air and this could result in an explosion.

36. Never use the tool in an explosive atmosphere Sparks from the tool may ignite atmospheric gases, dust or other combustible materials. 37. Be sure to earth the compressor Earth the compressor to prevent a worker from getting an electric shock. It comes with a 3-pole cord and a 3-pole earthing plug so that it can be connected to an appropriate earthing plug socket. A green-and-yellow striped wire is an earthing conductor. Never connect it to other charged terminals. 38. When carrying the compressor, hold it correctly. Carry the compressor in a proper manner by holding its grips with both hands. (Fig. 3) 39. Take care to transport the compressor correctly, do not overturn it or lift it with hooks or ropes. 40. When disposing the machine or tis parts, follow the relevant national rules.

SPECIFICATIONS

ModelEC1433H Power supply230 V AC 50Hz Rated current5.2 A Motor power950 W (1.27 HP) Protective earthingClass I Protective structureIP20 Working temperature5°C to +40 °C Working humidity85 % RH or less. No dew condensation. Height above sea levelUp to 1000 m Storage temperature-10 to +50 °C Storage humidity85 % RH or less. No dew condensation. Pressure switch working rangeOff : 3.25 MPa (32.5 bar) [471.4 psi]/On: 2.6 MPa (26 bar) [377.1 psi]

INSTRUCTIONS FOR OPERATION

1. Installation

WARNING ○ Never use the machine in a place where any volatile combustible substance has been stored. (Fig. 2) Never use it near gasoline, thinner, gas, paint or adhesive agent, because they could be ignited or blow up. ○ Never use the machine near the heat of fi re or any combustible substance. ○ Never use the machine in an unstable place. (Fig. 4) Never use it in a place where it could move or fall of itself. Be sure to install the compressor on a fl at fl oor, with leg rubber underneath it; the allowable tilt angle of the fl oor is up to 10 degrees. If the installation fl oor is tilted and slippery, ensure that the compressor does not move during operation. Do not use it on a shelf or a stand where it may fall or tumble. ○ Avoiding a place exposed to high temperature or the direct sunshine, be sure to use the machine in the well-ventilated shade. Using it under high temperature or in the direct sunshine not only deteriorates its durability, but increases the temperature of the main body, causing danger to your safety. Be sure to use it in the well-ventilated shade. The adequate room temperature is +5°C to +40°C.

Unpack the compressor and check for any defi ciency, damage caused during transportation and loose bolts and screws.

WARNING Read section titled "SAFETY WARNINGS" Wear safety glasses or goggles Danger to the eyes always exists due to the possibility of dust being blown up by the exhausted air or of a fastener fl ying up to the improper handling of the tool. For these reasons, safety glasses or goggles shall always be worn when operating the tool. NOTE: ○ Non-side shielded spectacles and face shields alone do not provide adequate protection. ○ The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that diff er from those on your own compressor.

Page 8 of the Hitachi EC1433H user manual — "I" : ON "O" : OFF ( )
Seite 8 · Zum Vergrößern klicken
Seite 8

○ Do not install the machine in a dusty (wooden chips, etc.) Place. ○ Install the machine in the appropriate direction. Install it appropriately. ○ Never install the machine in the rain or in a place splashed with water or exposed to high temperature. (Fig. 1) Using it in the wet condition could cause an electric shock or a short-circuit, resulting in a fi re due to burnout or ignition.

○ Never block a ventilation opening or use the machine in a box or a narrow place(in a vehicle, etc.) (Fig. 5) Neglect of this may generate abnormal heat, causing a trouble or an accident. Install the compressor at the distance of 1 m or more from the wall to secure suffi cient ventilation and cooling. ○ Never sit or place an object on the top of the machine. Neglect of this could cause a trouble or break it. ○ Do not use the compressor in any place where the temperature is 5°C or less or the ambient temperature exceeds +40°C.

2. Name of parts

"I" : ON "O" : OFF ( )

Hitachi EC1433H — "I" : ON "O" : OFF ( ) diagram (page 8)
Abb. 3

Pressure gauge for indicating the set reduction valve pressure (2 gauges)

Pressure gauge in the tank

High-pressure air socket (for Hitachi high pressure tools)

Regular-pressure air socket (for Regular pressure tools)

Show 5 more labels / short text on this page
Power switch · Drain lever · Drain tube · Power cord · Power plug
Page 9 of the Hitachi EC1433H user manual — "I" : ON "O" : OFF ( )
Seite 9 · Zum Vergrößern klicken
Seite 9
3. Machine operating procedure

(11) Open the drain lever to discharge all the compressed

air and water in the air tank. If you found any abnormalities in the checkup or inspection prior to the operation, send the machine to your dealer or authorized service facility for inspection or repair.

Inspection and checkup prior to operation

  • WARNING ○ Prior to use, check the bolts and nuts for loosening and the parts for missing one. ○ The power supply used must 230 VAC 10 A and provided with a circuit breaker. Allowable source voltage range is +/-10%. ○ Width and length of the extension cord or drum cord used must be 2.5 mm 2 minimum and 20 m maximum, respectively. And the cord must be fully drawn out when used. ○ Make sure the machine is installed in the right direction when using it.
  • Use the machine in compliance with the instructions provided in "SAFTY WARNINGS" on page 5.
  • Pressure values in the description do not include the error in reading the pressure gauge. (1) After turning off the machine power switch, connect the earthing plug of the power plug to ground and then connect the power plug to the outlet. When using an extension cord or drum cord, make sure its eff ective cross section and length are 2.5 mm 2 minimum and 20 m maximum, respectively. (2) Turn the power switch on while maintaining the drain lever fully open. (3) Make sure that the motor starts to run and the air is leaking from the drain tube when the drain lever is open. (4) Close the drain cock and make sure no air is leaking from the tube. ( Fig. 6 ) (5) Turn the adjustment handle (in 2 locations) of the pressure-reduction valve fully clockwise until you cannot move it anymore and make sure that the above operation moves the pressure gauge pointer (upward) at both locations. CAUTION As the pressure in the air tank increases due to the pressure characteristic of the pressure-reduction valve, the pressure can vary from the set supply pressure by as much as 2 bar. Turn the pressure-reduction valve's adjustment handle counterclockwise once to reduce the pressure and then proceed to the adjustment while increasing the pressure by turning the adjusting hand clockwise. (6) Make sure that the compression operation is automatically stopped in 6 to 7 minutes. Except when auxiliary tank is connected or voltage drop occurred, since these extends the operating hours. (7) Wait for 5 minutes after the operation is stopped to confi rm that there are no abnormal noises or air leakages and that the compressor does not restart. (8) Discharge the compressed air by opening the drain lever somewhat. Make sure that the operation is resumed due to a decrease in the pressure. (9) Close the drain lever and turn the power off while the compression operation is turned on to make sure that these actions stop the machine from operating. (10) Turn the adjustment handle (in 2 locations) of the

Operating procedure Before operating the machine, be sure to carry out the "Inspection and checkup prior to operation" described on page 9. (1) Fully open the drain lever and turn the power switch on. After the operation has started, close the drain lever tight to increase the pressure. (2) After confi rming the operation has stopped due to the increased pressure, turn the adjustment handle of the pressure-reduction valve to adjust the operating pressure of the nailer and pneumatic tool to the appropriate level. When adjusting the pressure, turn the pressure-reduction valve's adjustment handle counterclockwise to set the pressure at a level lower than the appropriate value by 2 bars once. Then proceed to the adjustment while increasing the pressure by turning the handle clockwise. (Fig. 7) ○ Make sure to start the adjustment at a level lower than the appropriate pressure and continue the adjustment while increasing the pressure from that level upward. If you start the adjustment from a level higher than the appropriate value, an error results between the pressure gauge value and actually used pressure. (Due to Characteristics of pressure-reduction valve respectively) ○ 2 pressure-reduction valves provided on this machine allow you to connect Hitachi high pressure tools and the general-purpose nailer or pneumatic tool. Allows connection and use of Hitachi high pressure tools (of operating pressure of 25 bars maximum) Allows connection and use of the general-purpose nailers or pneumatic tools (of operating pressure of 8 bars maximum)

WARNING ○ You must observe the specifi ed operating air pressure for the nailers and pneumatic tools. Using a nailer or pneumatic tool without adjusting the supply pressure with the reduction valve can seriously degrade their performance, induce their premature aging or damage them. ○ Using a nailer or pneumatic tool at an inappropriate pressure level (at an unnecessary high pressure) increases their air consumption, potentially degrading their capability in continuous work. Be sure to use them at the appropriate pressure. (3) After you have fi nished with the adjustment of supply pressure, you can start the operation by connecting the air hose to the air outlet (air socket). (Fig. 8) (4) Connect the high pressure hose to the high pressure air hose for Hitachi high pressure tools to the high pressure air socket on the H side of the pressure- reduction valve. Connect the air hose for the general-purpose nailer to the air socket on the L side of the pressure-reduction valve. The air socket is the one-touch type, allowing you to connect the air plug to the air socket just by pushing in.

pressure-reduction valve counterclockwise to make sure that this turning moves the pressure gauge pointer downward at both locations. (You may hear sounds due to air leaking but it does not mean there is a failure.) (Fig. 7)

Page 10 of the Hitachi EC1433H user manual — IN ORDER TO MAINTAIN PERFORMANCE
Seite 10 · Zum Vergrößern klicken
Seite 10

PROTECTIVE DEVICE

This compressor is equipped with the protective device which stops the operation automatically when any abnormality is found in the voltage or motor. If the motor stops the operation, take an appropriate action with reference to the table below.

CauseAction taken Voltage is tool low or high1. Turn the power switch off and disconnect the power plug from the outlet. 2. Check and correct the connection to the power or extension code (page 6), and then connect the power plug to the outlet and turn the power switch on to resume the operation. ○ Motor temperature went abnormallly high ○ Temperature in the control circuit has built up to an abonormally high level1. Turn the power switch off and disconnect the power plug from the outlet. 2. Connect the power plug to the outlet and turn the power switch on to resume the operation. If the motor has suffi ciently cooled down, the resumed operation may active the protective device soon after. In other cases, the operation may not resumed when you turned the power switch on. In such a case, wait for about 30 minutes for the motor to cool own before restarting the machine.

ABNORMALITIES DURING OPERATION

2. Implement the machine inspection on a regular basis. The User is requested to implement cleaning and inspection of the machine in order to maintain its performance. Please do not hesitate to let your dealer or authorized service facility inspect your machine. 3. Handle this machine carefully. Dropping the machine inadvertently, bumping it against solid objects or hitting it can cause deformation, cracks or damage to the machine. The User is advised not to invite an accident by dropping, bumping or hitting the machine. 4. Inspect the machine every time you use it. Check and inspect the machine in conformance with the procedure described in the "SAFETY WARNINGS" provided on page 5 and after.

WARNING If you detect any abnormalities, do not operate the compressor. If you encounter any of the following abnormal phenomena, turn off the power switch immediately, disconnect the power plug from the outlet and send the machine to your dealer or authorized service facility for checkups or repairs. 1. The following problems may occur even when there are no problems with the power supply or wiring: (See "PROTECTIVE DEVICE") ○ Turning on the power switch does not start up the machine. ○ Motor vibration is generated 2. Abnormal sounds are generated during operation. 3. The safety valve instead of the pressure sensor is activated, allowing the compressed air to blow out. 4. Air leakage happens. 5. Pressure does not increase. 6. An electrical shock-like pain is felt when touched the metal part. 7. Other abnormalities than the above that is recognized during operation.

GUARANTEE

We guarantee Hitachi Power Tools in accordance with statutory/country specifi c regulation. This guarantee does not cover defects or damage due to misuse, abuse, or normal wear and tear. In case of complaint, please send the Power Tool, undismantled, with the GUARANTEE CERTIFICATE found at the end of this Handling instruction, to a Hitachi Authorized Service Center.

IN ORDER TO MAINTAIN PERFORMANCE

Sound Pressure Noise EC1433H LPA 72 dB (A) For the European market, the compressors are manufactured to meet Directive 2006/42/EC.

1. Drain water from the machine. After the work is fi nished, turn the handle of the pressurereduction valve clockwise and open the drain cock gradually to drain the compressed air and water in the air tank until the pressure gauge pointer of the pressurereduction valve points to 0. ○ Not draining the water will result in the inside of the air tank becoming moldy, potentially leading to a failure.

The sound generated by the workstation is indicated as sound pressure level measured free-fi eld at a distance of 1m.

Wear hearing protection.

Frage zu Hitachi EC1433H stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Hitachi EC1433H

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Hitachi EC1433H PDF-Anleitung

60 Seiten·3.4 MB·Kompressor·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…