REFERENCES 54068-MB (B100M) 54069-MB (B150M) 54070-MB (B150T) 54071-MB (B200M) 54072-MB (B200T) 54073-MB (B250M) 54074-MB (B250T) 54075-MB (B300T)
54078-MB (R100M) 54079-MB (R150M) 54080-MB (R150T) 54081-MB (R200M) 54082-MB (R200T) 54083-MB (R250M) 54084-MB (R250T) 54089-MB (R300T)
TECHNICAL MANUAL. START-UP AND OPERATION · MANUAL TÉCNICO. ARRANQUE Y FUNCIONAMENTO · MANUEL TECHNIQUE. MISE EN ROUTE ET FONCTIONNEMENT · TECHNISCHES HANDBUCH. INBETRIEBNAHME UND BETRIEBSWEISE · MANUALE TECNICO. AVVIAMENTO E FUNZIONAMENTO · MANUAL TÉCNICO. ARRANQUE E FUNCIONAMENTO



EDITION: 3





1. INTRODUCCION 37 2. DESCRIPCION DE LA BOMBA DE CALOR 37 2.1. CARECTERISTICAS TECNICAS 37 3. PRECAUCIONES DE EMPLEO Y CONDICIONES DE USO 38 3.1. INSTRUCCIONES DE SEGURIDAD 38 3.2. CONDICIONES DE INSTALACION 38 4. PUESTA EN MARCHA DE LA BOMBA DE CALOR 39 4.1. REGLAS DE INSTALACION 39 4.2. CONEXIONES HIDRAULICAS 40 4.3. CONEXIÓN ELECTRICA 40 4.4. DIAGRAMAS ELECTRICOS 41 4.4.1. DIAGRAMA MONOFASICO 41 4.4.2. DIAGRAM TRIFASICO 41 5. FUNCIONAMIENTO DEL EQUIPO 41 5.1. MODOS DE FUNCIONAMIENTO 41 5.2. CONTROLES 42 5.3. CONFIGURACION DEL EQUIPO 42 5.4. CONSIGNA DE TEMPERATURA 42 5.5. ENCENDIDO DEL EQUIPO 43 5.6. MENU DE USUARIO 43 5.7. MENU TECNICO 43 5.8. MENSAJES DE INFORMACION 46 5.9. LEDS 46 5.10. CONTROL POOL / SPA (OPCIONAL) 47 5.11. EOM ENERGY EFFICIENT MODE 47 5.12. MENSAJES DE ALARMA 48 5.13. MANDO A DISTANCIA 49 5.14. REGULACION DE LA TEMPERATURA 50 5.15. PARO EXTERNO 50 5.16. MODBUS 51 6. PROCEDIMIENTO DE PUESTA EN MARCHA DE LA BOMBA DE CALOR 51 7. PROCEDIMIENTO DE HIBERNACION 52 8. INSTRUCCIONES DE MANTENIMIENTO 52 9. CARGA DE GAS REFRIGERANTE 53 10. AVERIAS, CAUSAS Y SOLUCIONES 55 11. REPUESTOS 57 11.1. INFORMACION PARA HACER PEDIDO 57 11.2. LISTADO DE REPUESTOS 57 11.3. VISTA EXPLOSIONADA BOMBA DE CALOR 59 12. RECICLAJE DEL PRODUCTO 59 13. GARANTIAS 60

1. INTRODUCTION 64 2. DESCRIPTION DE LA POMPE À CHALEUR 64 2.1. CARACTERISTIQUES TECHNIQUES 64 3. PRECAUTIONS D’EMPLOI ET CONDITIONS D’UTILISATION 65 3.1. INSTRUCTIONS DE SECURITE 65 3.2. CONDITIONS D’INSTALLATION 65 4. MISE EN ROUTE DE LA POMPE À CHALEUR 66 4.1. NORMES D’INSTALLATION 66 4.2. RACCORDEMENTS HYDRAULIQUES 67 4.3. CONNEXION ELECTRIQUE 67 4.4. SCHEMAS 68 4.4.1. SCHEMA ELECTRIQUE MONOPHASE 68 4.4.2. SCHEMA ELECTRIQUE TRIPHASE 68 5. FONCTIONNEMENT DE L'ÉQUIPEMENT 68 5.1. MODE DE FONCTIONNEMENT 68 5.2. CONTROLES 69 5.3. CONFIGURATION DE L'EQUIPEMENT 69 5.4. CONSIGNE DE TEMPERATURE 69 5.5. MISE EN MARCHE DE L'EQUIPEMENT 70 5.6. MENU UTILISATEUR 70 5.7. MENU TECHNIQUE 70 5.8. MESSAGES D’INFORMATION 73 5.9. LEDS 74 5.10. POOL / SPA CONTROL (OPTION) 74 5.11. MODE D'EFFICACITÉ ÉNERGÉTIQUE EOM 74 5.12. MESSAGES DES ALARMES 76 5.13. TELECOMMANDE 77 5.14. TEMPERATURE REGULATION 78 5.15. ARRET EXTERNE 78 5.16. MODBUS 79 6. PROCESSUS DE MISE EN ROUTE DE LA MACHINE 79 7. PROCESSUS D’HIVERNAGE 80 8. INSTRUCTIONS D’ENTRETIEN 80 9. CHARGE DE GAZ RÉFRIGÉRANT 81 10. PANNES, SES CAUSES ET SOLUTIONS 83 11. PIÈCES DE RECHANGE 85 11.1. INFORMATION POUR PASSER UNE COMMANDE 85 11.2. LISTE DES PIECES DE RECHANGE 85 11.3. EXPLODED VIEW 87 12. RECYCLAGE DU PRODUIT 87 13. GARANTIES 89


ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
Thank you for acquiring the heat pump for heating outdoor swimming pools. The experience our company has gained over more than 25 years in the world of conditioning of swimming pools has been put to your service in this product, in which we also incorporate the technical breakthroughs that turn this heat pump into the equipment that can solve once and for all the air conditioning of your swimming pool, extending thus the length of your bathing season.
Please, read this manual carefully in order to: make a successful installation and Please, read this manual carefully in order to: make a successful installation and Please, read this manual carefully in order to: make a successful installation and Please, read this manual carefully in order to: make a successful installation and start-up, know the know the know the know the total potential of the machine, and take into account all the needed potential of the machine, and take into account all the needed potential of the machine, and take into account all the needed potential of the machine, and take into account all the needed circumstances for a proper and circumstances for a proper and circumstances for a proper and circumstances for a proper and long-lasting performance. lasting performance. lasting performance. lasting performance.
IT IS SUGGESTED THAT NOTE BE MADE OF THE FOLLOWING DATA IT IS SUGGESTED THAT NOTE BE MADE OF THE FOLLOWING DATA IT IS SUGGESTED THAT NOTE BE MADE OF THE FOLLOWING DATA IT IS SUGGESTED THAT NOTE BE MADE OF THE FOLLOWING DATA
DATE DATE DATE DATE
TELEPHONE TELEPHONE TELEPHONE TELEPHONE
MODEL MODEL MODEL MODEL
SERIAL NUMBER SERIAL NUMBER SERIAL NUMBER SERIAL NUMBER
DEALER’S STAMP INSTALLER’S STAMP
This heat pump is used to heat water from a pool or spa and thus extend bathing season.
2.1. TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA
See TABLE 1 (page 178).
Operational temperature limits:
Maximum Inlet Water Pressure = 3, 5 bar.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
3.1. SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS
Read the safety instructions prior to any manipulation:
Any incorrect manipulation may cause serious damages Any incorrect manipulation may cause serious damages Any incorrect manipulation may cause serious damages Any incorrect manipulation may cause serious damages to the unit the unit the unit the unit and to the user and to the user and to the user and to the user that could involve deadly injuries could involve deadly injuries could involve deadly injuries could involve deadly injuries.
3.2. INSTALLATION CONDITIONS INSTALLATION CONDITIONS INSTALLATION CONDITIONS INSTALLATION CONDITIONS
Do not install the unit near a flammable gas source, since a gas leak may occur and cause an explosion.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
In order to obtain an optimal operation of the heat pump, certain norms must be respected:
4.1. INSTALLATION RULES INSTALLATION RULES INSTALLATION RULES INSTALLATION RULES
It is necessary to determine the unit location according to certain criteria:
4.2. HYDRAULIC CONNECTIONS HYDRAULIC CONNECTIONS HYDRAULIC CONNECTIONS HYDRAULIC CONNECTIONS
Remove the seals from the three piece connections of the water intake on the heat pump. Connect the PVC 50 piping water inlets and outlets of the swimming pool to the heat pump inlet

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
and outlet. The connection will be performed through a by-pass over the filtering circuit of the swimming pool, after the filter and before the water treatment. Adjust the flow so that the arrow of this pressure gauge in the green zone. See IMAGE 1 (page 181). If it is not possible to install the doser/chlorinator 25cm below water discharge of the heat pump, a siphon should be installed. For additional security, a check valve should also be installed to prevent the chemical product from returning to the pump when water circulation is interrupted. The unit is provided with two D-50 PVC unions. There must be water flowing through the hydraulic connections when the unit is running. Never place concentrated chemicals in the swimming pool skimmers. A full-flow shut-off valve should be installed on each of the hydraulic elements in the equipment, so that each of these may be isolated if needed (for filter cleaning, repairs, substitutions, etc.) without the need to drain the circuit. Anti-vibration dampers should be installed in the inlet and outlet of the machine, in order to avoid vibrations which may cause cracks or breakage in the hydraulic connections. In order to avoid possible breakage, do not force the PVC tubes connected to the water supply.
4.3. ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS
The power supply for the heat pump must be, preferably, from a sole circuit provided with standard-issue protection components: protection by a 30 mA differential and a magnetic circuit breaker. See IMAGE 2 (page 182)
Electrical installation must be carr Electrical installation must be carr Electrical installation must be carr Electrical installation must be carried out by a qualified professional according to the ied out by a qualified professional according to the ied out by a qualified professional according to the ied out by a qualified professional according to the applicable laws and regulations of the region country. applicable laws and regulations of the region country. applicable laws and regulations of the region country. applicable laws and regulations of the region country.
The heat pump circuit must be linked to a safety earth circuit levelled to the terminal block. The cables must be correctly installed so that they do not cause interferences (items in the lead boards). The heat pump may be connected to an earthed 1-Phase 230 VAC 50Hz general-purpose power supply. All wiring should comply with local and national electric codes and should not be prone to overheating and subsequent voltage failures. The acceptable tolerance to voltage fluctuation is +/- 10% during operation. Table 2 shows some indicative sections, which must be verified and adapted according to the installation needs and conditions. See TABLE 2 (page 180). PROCEDURE:

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
The heat pump should always operate in conjunction with the purification pump. Be The heat pump should always operate in conjunction with the purification pump. Be The heat pump should always operate in conjunction with the purification pump. Be The heat pump should always operate in conjunction with the purification pump. Be careful when interconnecting timers or programmers which may stop the purification careful when interconnecting timers or programmers which may stop the purification careful when interconnecting timers or programmers which may stop the purification careful when interconnecting timers or programmers which may stop the purification pump and leave the heat pump pump and leave the heat pump pump and leave the heat pump pump and leave the heat pump without water flow without water flow without water flow without water flow.
4.4. ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM
4.4.1. SINGLE PHASE DIAGRAM SINGLE PHASE DIAGRAM SINGLE PHASE DIAGRAM SINGLE PHASE DIAGRAM See IMAGE 4 (page 183) 4.4.2. TRIPHASIC DIAGRAM TRIPHASIC DIAGRAM TRIPHASIC DIAGRAM TRIPHASIC DIAGRAM See IMAGE 5 (page 184) 5. OPERATION OF THE UNIT OPERATION OF THE UNIT OPERATION OF THE UNIT OPERATION OF THE UNIT
5.1. OPERATION MODES OPERATION MODES OPERATION MODES OPERATION MODES
Note that these operation modes are accumulative between them: For instance, y Note that these operation modes are accumulative between them: For instance, y Note that these operation modes are accumulative between them: For instance, y Note that these operation modes are accumulative between them: For instance, you can ou can ou can ou can set up a unit to heat Spa water in comfort mode and EOM efficient operation activated. set up a unit to heat Spa water in comfort mode and EOM efficient operation activated. set up a unit to heat Spa water in comfort mode and EOM efficient operation activated. set up a unit to heat Spa water in comfort mode and EOM efficient operation activated. What is not possible is to make a unit work on both modes of the same category: For What is not possible is to make a unit work on both modes of the same category: For What is not possible is to make a unit work on both modes of the same category: For What is not possible is to make a unit work on both modes of the same category: For instance, you cannot set up a unit in both Comfort and Filtration modes. instance, you cannot set up a unit in both Comfort and Filtration modes. instance, you cannot set up a unit in both Comfort and Filtration modes. instance, you cannot set up a unit in both Comfort and Filtration modes.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5.2. HEAT PUMP CONTROLS AT PUMP CONTROLS AT PUMP CONTROLS AT PUMP CONTROLS
See IMAGE 6 (page 186) to see a detailed description of the heat pump controls.
5.3. UNIT SE UNIT SE UNIT SE UNIT SET UP
Select Pool, Spa or both by pressing . Each one, Pool and Spa, have its own temperature set point. Note that pool-spa is optional equipment.
navigate down by pressing until operation mode screen appears; then select Comfort or
filtration by pressing or .
5.4. SETTING TEMPERATURE SET POINT SETTING TEMPERATURE SET POINT SETTING TEMPERATURE SET POINT SETTING TEMPERATURE SET POINT
Temperature set point can be changed at any time (as long as outside Users Menu):
5.5. UNIT START UP UNIT START UP UNIT START UP UNIT START UP
When the unit has been connected to a power supply the green led illuminates to indicate that the unit has power.
Once Set up process is completed, press to power on the unit. Green light will start flashing, indicating that the unit has been turned on.
Press again to enter economic mode: The default economic mode is ECO. If EOM mode is to be used, first has to be activated on technical menu, as well as its efficiency grade.
Press again to STOP the unit. This constitutes the operation loop.
Display will leave any screen to the default information screen after a given time period, or will leave any screen to the default information screen after a given time period, or will leave any screen to the default information screen after a given time period, or will leave any screen to the default information screen after a given time period, or if the if the if the if the MENU key is pressed key is pressed key is pressed key is pressed
5.6. USERS MENU USERS MENU USERS MENU USERS MENU
On User menu, operation modes can be selected, as well as other parameters:
To enter User menu just press key on the control display. The first screen shown is the software version of the heat pump.
To navigate through user menu screens, just press to move down and to move up.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
To change current screen parameter, just press or .
5.7. TECHNICAL MENU TECHNICAL MENU TECHNICAL MENU TECHNICAL MENU
On technical menu, further parameters can be modified, though these parameters rarely are to be modified once the unit is installed.
Ver X.XX
Parameters on technical menu should not be changed since are factory settings proven to Parameters on technical menu should not be changed since are factory settings proven to Parameters on technical menu should not be changed since are factory settings proven to Parameters on technical menu should not be changed since are factory settings proven to get the most of your unit. If you want to change these parameters anyway, take special get the most of your unit. If you want to change these parameters anyway, take special get the most of your unit. If you want to change these parameters anyway, take special get the most of your unit. If you want to change these parameters anyway, take special caution.
Technical menu screens are as follow:
Allows defining an offset on water temperature values. Useful to correct inaccurate readings. Reset of the calibration by pressing MENU key. Allows defining an offset on environment air temperature values. Useful to correct inaccurate readings. Reset of the calibration by pressing MENU key.
ENV 60.5ºC
Set point differential temperature; defines the set point temperature gap. Maximum value of 10º C/F
Extra differential temperature added to Differential Temp parameter when ECO mode is active. If ECO Temp Diff is set to zero then the user cannot use the ECO mode. This screen defines the grade of energy efficiency the unit will work on, where *** is the lowest grade of efficiency and ***** is the highest. This screen sets whether the unit has control over the filtration system or not. If this screen is set to Disabled, the unit will only be able to heat water when the filtration system in on.
EOM * * *
This screen enables or disables the possibility to select Comfort as an operation mode. If this screen is set to Disabled, the unit will only be allowed to work on Filtration mode.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
This screen enables or disables the possibility to select SPA as an operation mode.
1) Disabled: the unit will work only on Pool mode. 2) User Control: The unit will be able to work on Pool or/and Spa water, user selectable. 3) External Control: The unit will work on Pool or/and Spa by means of external terminals, see 5.15. (Page 24). This screen set the time the unit will stop water flow during a Pool ↔ Spa change. This time reflects the time needed for the 3 way valves to switch from Pool ↔ Spa. It is useful to set a time slightly larger than required to assure that the change is complete. This screen sets the timing when the unit is set to heat Pool and Spa. In this example, the unit will heat Spa for 1 hour and then will change to heat Pool for 3 hours. If temperature setting is achieved, unit will change immediately. This screen represents the time lapse between when the machine should activate and when it really does. This screen only appears if “Comfort function” is activated. Only appears if “Comfort function” is activated. This screen represents time lapse between water temperature readings. For instance, when water temp is within set point, unit will check every 30 min whether water has come out of set point.
V.SPA Time
Mode SPA+POOL Cycle 1h / 03h
Only appears if “Comfort function” is activated. This screen represents time lapse between water temperature readings in SPA. For instance, when water temp is within set point, unit will check every 5 min whether water has come out of set point. Depending on the units characteristics 3 types of defrost can be selected:
1 / 2 / 3
1) Fan stop: By air with fan off. 2) Air + Fan: By air with fan on. 3) Cycle inversion: by hot gas by reversing the frigorific circuit. (only reversible machines) This screen sets the radio channel the unit will use to communicate with the remote. In order to work properly, remote has to be set to the same radio channel. This screen sets if test mode is enabled. Test mode is reserved for technicians that need to diagnose the unit.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
On this screen, by holding + key for 5 seconds will reset all unit’s parameters, reverting them to factory settings.
This screen shows a record that stores the unit’s actions.
This screen shows the time period the unit has been activated.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5.8. INFORMATION MESSAGES INFORMATION MESSAGES INFORMATION MESSAGES INFORMATION MESSAGES
The Information Messages appear on the screen without the need to press any key. These messages indicate what the system is doing at any given moment.


The machine is stopped. Does not heat because the user chooses not to.

Heat Pump External Stop
The heat pump is stopped due to AUX entry. The AUX entry can be used to program an external clock. (See chapter 5.15. (page 24).

Heat Pump No Water Flow
The water is not circulating. The flowswitch signal indicates there is no water flow.

Defrosting Water T. XX.XºC

Defrost function is being performed.

Verify Temp.

Verifying temperature. Waiting the set time delay, countdown displayed.


Countdown for the machine to begin heating. Complying with fan or compressor delay time.

The machine is heating and reports the pool water temperature. If the machine is operating in ECO or EOM mode, this is displayed on the screen.

Heating ECO Water T. XX.XºC
Temp OK Water T. XX.XºC
The water temperature is as programmed by the user (within the set margin) and indicates water temperature.

Heat Pump Very cold air

The machine is stopped because the ambient temperature is very low.

EOM Stop Low performance

The machine is stopped because the ambient energy is very low, according to EOM operation mode.

This screen indicates that to perform the requested operation first the unit has to be stopped.
This screen indicates that the requested operation is not available, for instance: Cool on a regular unit.

Indicates that at the time of performing a change Pool ↔Spa the flow was not stopped by the pump override system.
Fixed Green System is performing the normal heating process.
Flashing Green System is performing some necessary process to begin the normal heating process (Defrost, delay times...). Green Off No power, system off or an alarm has gone off. Red On System is off because an alarm has gone off

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5.10. POOL / SPA CONTROL (OPTIONAL) POOL / SPA CONTROL (OPTIONAL) POOL / SPA CONTROL (OPTIONAL) POOL / SPA CONTROL (OPTIONAL)
Pool / Spa control allows the heat pump to heat water on a pool or a Spa or both alternatively. The unit is able to control the 3-way-valves used to configure the hydraulic circuit on Pool or Spa modes. Connection depends on water hydraulic system layout. Two main configurations can be considered:
Pool / Spa optional consists of an extra electronic board which is assembled directly to the main board and a 24V AC power transformer that will power on the hydraulic 3-way-valves.
See IMAGE 9 (page 189)
In order to control the configuration of the hydraulic system, the 3-way-valves must be connected to the Pool-Spa control PCB. Whether 3 or 2 valves hydraulic configuration system is present, connect the valves to terminals marked as V1, V2 and V3, taking into account normally close (N.C.) / normally open (N.O.) and common (COM) terminals. See IMAGE 10 (page 189).
Pool / Spa board also includes a filtration pump control connector in order to manage Spa filtration system in case there are two filtration systems: one for the pool (controlled by main board) and another one for the spa. See IMAGE 10 (page 189).
5.11. EOM ENERGY EFFICIENT MODE EOM ENERGY EFFICIENT MODE EOM ENERGY EFFICIENT MODE EOM ENERGY EFFICIENT MODE
While in EOM efficiency mode, the APHeat heat pump continuously checks energy available in the environment as well as the thermal inertia of the water and will decide whether it is efficient to heat the water pool or not.
Keep in mind that all energy efficiency modes have the advantage of savings in equipment operating costs, but also involve some drawbacks.
Pictures 11 & 12 describe the operation of the APHeat Heat pump in EOM mode:
IMAGE 11 (page 190) describes the operation of a heat pump for 3 days, configured to maintain water set point, ie without any energy efficiency method activated. As we can see, the unit works even when the available energy in the environment is low (the unit has a weak performance), as it has been configured to maintain the set point temperature under all circumstances.
By contrast, IMAGE 12 (page 190) shows operation of the same unit during the same 3 days, but with the EOM energy efficiency method activated. As we can see, there are certain time periods when the unit is not allowed to run, because the unit knows that there is little energy available in the environment. At the time when there is available energy, the unit will work again.
The great advantage of this mode is that we can obtain equipment operating cost savings up to 40%
The drawback is that in periods when low energy is available in the environment, since the unit does not work, the pool water temperature will drop. But presumably, in these periods of low energy, the user of this pool is not very prone to bathe as little energy in the air means cold air. When the air temperature rises again and the machine detects that it is efficient to operate, it

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
will rise water temperature back to the set point quick and efficiently, since there is energy available on the environment.
5.12. ALARM MESSAGES ALARM MESSAGES ALARM MESSAGES ALARM MESSAGES
Alarms may be rearmed either automatically or manually. The following Alarm Messages may appear on the screen:

Serious Error Power Failure

System power failure. The order of the three phases is inverted. Automatically and immediately rearms when the problem is solved.

Serious Error Thermal Motor
The thermal circuit is open. Failure in the thermal system. Semi-automatically rearmed when the problem is solved and the MODE key is pressed.

The high pressure switch indicates the circuit is open. Pressure is too high. Semi-automatically rearmed when the problem is solved and the MODE key is pressed.
Serious Error High Pressure

The high pressure switch indicates the circuit is open. Pressure is too low. Semi-automatically rearmed when the problem is solved and the MODE key is pressed.
Serious Error Probe Failure W

Failure in the water sensor reading. Automatically and immediately rearms when the problem is solved.
Serious Error Probe Failure CO
Failure in the condenser sensor reading. Automatically and immediately rearms when the problem is solved.
Serious Error Probe Failure EV

Failure in the evaporator sensor reading. Automatically and immediately rearms when the problem is solved.

Serious Error Probe Failure EN
Failure in the ambient sensor reading. Automatically and immediately rearms when the problem is solved.
No water flow. Automatically and immediately rearms when the problem is solved.


If there is a failure in the thermal sensor or the pressure switches, retry up to three times daily. Manual rearming with technical assistance.
Serious Error Repeated Failure

The equipment checks fan operation. If the fan does not work properly, the unit stops. Semi-automatic rearm: every 30 minutes the unit will try to start working again.


The equipment checks the 4 way valve whenever it has to be engaged. If it is not working properly, the unit stops. Semi-automatic rearm: every 30 minutes the unit will try to start working again.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5.13. WIRELESS REMOTE CONTROLLER WIRELESS REMOTE CONTROLLER WIRELESS REMOTE CONTROLLER WIRELESS REMOTE CONTROLLER
With a full 2, 5’’ wide screen, all data concerning the operation of the unit can be read at a glance; also, useful information can be read, like the water or ambient temperature. All user functions can be performed by means of this remote controller.

Changes operation mode to Pool or Spa or Pool+Spa.


Indicates that the requested operation can’t be done1.
Shows if the unit is heating or cooling or both.
Shows whether the unit is working on Pool or Spa or both.
In order to properly set connection between the unit and the wireless remote controller, both devices are to be set on the same communication channel. All units are configured on channel
1 For instance, trying to set up a regular unit to cool, or trying to work on Spa if the unit can only work on Pool.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
To set the communication channel on the heat pump, see chapter 5.7. (Page 17), technical menu. There is a screen that sets the radio channel:
To set the communication channel on the wireless remote, press at the same time the keys
and . After a few seconds, it will appear on the display the currently radio channel. To
change it, just press or . Once set the desired radio channel, just press button once to leave the configuration screen.
5.14. TEMPERATURE REGULATION TEMPERATURE REGULATION TEMPERATURE REGULATION TEMPERATURE REGULATION

5.15. EXTERNAL STOPPAGE EXTERNAL STOPPAGE EXTERNAL STOPPAGE EXTERNAL STOPPAGE
If the user must install any type of timing device or emergency stoppage device, it is important to know that such a device can be installed by connecting it directly to the power board of the system. The system is designed with external stoppage terminals which can be used for these purposes. These terminals are shown in IMAGE 13 (page 191).
Heat Pump External Stop
When these terminals are connected the machine will stop for external reasons and the following message will appear:
GENERAL MODE GENERAL MODE GENERAL MODE GENERAL MODE When we want the unit to stop by means of external stoppage, we are to short circuit two terminals, marked as EXT #1 in above figures. When these terminals are connected (short circuited) the unit will stop by means of external stop. Once the terminals are disconnected, the unit will start working again on the mode prior to external stop.
Radio Channel

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
POOL & SPA MODE SPA MODE SPA MODE SPA MODE When the unit is configured to heat Pool and Spa water, we can use both terminals, EXT #1 and EXT #2, to gain some extra capabilities (first SPA Control screen on technical menu has to be set to External control, see 5.7. 17).
The unit will work on Pool mode.
The unit will work on Spa mode
The unit will work on Pool + Spa mode
External Stop (same case as in general mode)

This Heat pump includes Modbus capabilities. For complete instructions for Modbus connection & communication, please consult Modbus manual at Fluidra PDB (Product Data Base): http://pdb.astralpool.com/pdb/
Operating requirements for the heat pump:
Before any start-up, you should check:
Performing the heat pump adjustments in its initial operation

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
The heat pump should always operate together with the purification pump. We must have the precaution to not interconnect timers or programmers which may stop the filtration pump thus making the unit work without water flow. The heat pump will take several days to reach the requested temperature: This is completely normal.
This operation must be obligatorily carried out by a professionally qualified person. It should be carried out at least once a year and includes several elements:
EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL The evaporator coil should be kept clean and free of obstacles which may hinder the circulation of air through them. In order to clean it, use water (little pressure) and non-abrasive detergents or cleaning liquids made specifically for it.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
COMPRESSOR Compressor oil must be checked in those unit models provided with an oil viewer. Verify that the compressor refrigerates adequately with the circulating gas (verify the refrigerant charge). Verify that the power consumption has not increased. Verify that the compressor discharge pressure is not too high and that the intake pressure is not too low. Verify that the compressor fasteners are not deteriorated. Verify that no frost develops on the compressor.
CONDENSER Install chemical feeders “downstream” from the heat pump, as far away and at a lower height. The feeder should never be installed near the intake of the purification pump as this will damage the condenser. NEVER introduce concentrated chemical products in the pool skimmers as this will damage the Titanium condenser. In climates where temperatures occasionally fall below freezing, circulate the water using the purification pump to maintain the water temperature above freezing (32º F). In the case these temperatures are persistent or habitual, the heating and purification system should be completely drained. The condenser has a lateral plug the purge the system.
FAN Verify the flows of the fan each year. Clean the louvers of the fan as well as the protection grill regularly.
ELECTRICAL PANEL ELECTRICAL PANEL ELECTRICAL PANEL ELECTRICAL PANEL Verify all electrical connections. Verify that there is no over-heating of the electrical terminals. Verify that the protection systems operate correctly. Verify that the regulator operates correctly and verify the temperature with a mercury thermometer (calibration probe).
For the procedures described below, we recommend you contact a professional specialised in heating and air conditioning units. DRAINING THE COOLING CIRCUIT DRAINING THE COOLING CIRCUIT DRAINING THE COOLING CIRCUIT DRAINING THE COOLING CIRCUIT It is imperative to drain the cooling circuit before charging the refrigerant. First draining procedure:

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
After having discharged the cooling circuit, and after having installed the charger and connected the flexible tubes of the gauge to the high and low-pressure circuits, we can proceed with the charge:
METHODS FOR SEARCHING FOR A GAS LEAK: METHODS FOR SEARCHING FOR A GAS LEAK: METHODS FOR SEARCHING FOR A GAS LEAK: METHODS FOR SEARCHING FOR A GAS LEAK: There are various tools on the market used in order to detect leaks, although not all of them are sufficiently sensitive to certain types of refrigerants. It is very important to choose an adequate detector for the refrigerant used for this equipment and that the maintenance guidelines by followed. You can also use soap bubbles (liquid detergent in a spray bottle) to detect leaks. Other methods such as halogen lighters and additives may also be used to detect leaks. THE R THE R THE R THE R-407C GAS: 407C GAS: 407C GAS: 407C GAS: The R-407C is a NONFLAMMABLE gas; it has no flash point, and so is not subjected to the rules and regulations of the transportation of inflammable gases. The R-407C does not irritate the skin, eyes or mucous membranes and does not produce any side-effects. It has a very low level of toxicity for one or many repeated exposures; it does not cause cancer or mutations.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
The R-407C may cause freezing if it comes into contact with the skin, due to its immediate evaporation. As with all hydrocarbons, whether they are halogenated or not, the R-407C gas may, although it has a very low level of toxicity, cause anaesthetic or preanaesthetic conditions if inhaled deeply and within a closed area.
The reasons why your heat pump may not function properly are mentioned below:
possible short circuit. o Coil contactor does not activate: Verify that it is not burned, and replace it if it is. Verify the
terminals which activate the coil. o Thermal switch tripped: Verify the voltage of the line. Verify that the operating conditions
are correct. Excessive compressor consumption. Short circuit in the compressor. o Low pressure switch tripped: Verify that the pressure switch operates correctly and
substitute if necessary. Verify that the fan is operating correctly. Verify the refrigerant charge of the equipment (refrigerant leak, loss of refrigerant fluids) in order to solve this problem; please refer to the refrigerant charge section. o Verify that there is sufficient ventilation around coils. Check for any obstruction of the cooling
circuit and eliminate the obstruction if necessary. Verify that the thermostatic valve is operating properly, checking the bulb has no gas leaks and that the pressure inlet is free of obstruction. Replace if needed. o High pressure switch tripped: Verify that the pressure switch operates correctly and
substitute if necessary. Check the refrigerant charge (excess refrigerant) in order to solve this please refer to the refrigerant charge section. Check for any obstruction of the cooling circuit and eliminate the obstruction if necessary. Verify there is a good water flow through the condenser, checking there are no obstructions in the hydraulic circuit, the shut-off valves are open and the purification pump operates properly (replace if needed). o Flow alarm: Verify the purification pump is operating properly (pump flow may be less than
needed). The filter of the purification pump is dirty. Clean it if needed. By-pass are closed or not sufficiently open. Revise it if needed. The pump is not working. Revise clock condition and purification mode. The flow switch is faulty (call for service). o Defrost cycle: The ambient conditions are not correct (temperatures are too low). The unit
does not work under these conditions. It is recommended to disconnect the unit.
o Low initial oil charge: Refill up to needed level. o Oil stains on the equipment: Check for leaks in the cooling circuit and repair them if
necessary, check the torque on the high and low pressure valves, and replace them if necessary.
o The low pressure switch opens then closes again: Verify the points mentioned in the "low
pressure switch tripped" section above. o Intermittent contact on machine control unit: Repair or replace the faulty electrical part.
Check the temperature indicator. o Make sure the equipment is not too large for the facilities.
o Verify that the thermostat functions properly, repairing or replacing it if necessary.

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
o Compressor contactor contacts are stuck together: Check that the coil is functioning properly
and that the contacts are not burned. o The pressure of the intake duct is too low: Check the refrigerant charge of the equipment for
leaks, to solve this problem please refer to the refrigerant charge section. Check that there are no obstructions in the cooling circuit, filter-drier, expansion valve, etc. and replace if necessary. Verify that the equipment is powerful enough for the existing thermal conditions. o Excessive noise: The fastening screws of the compressor or fan are loose: Tighten all the
fastening elements. o Check the compressor oil level. o The compressor produces internal bumping noises: Check that the noise does not come from
any fluid leak from overheating (see section of refrigerant charge).
11.1. ORDERING INFORMATION ORDERING INFORMATION ORDERING INFORMATION ORDERING INFORMATION
To order or purchase parts for the Astralpool Heat models of heat pumps, contact your nearest dealer or distributor. If they cannot supply you with what you need, contact the Astral Service Department.
11.2. PARTS LIST PARTS LIST PARTS LIST PARTS LIST
PART No. MODEL CODE MATERIAL 1 ABS Top Cover 100-150 54068R0001 1 ABS Top Cover 200-250-300 54071R0001 2 Fan Motor 100-150 54068R0002 2 Fan Motor 200-250-300 54071R0002 3 Fan Blade Set 100-150 54068R0003 3 Fan Blade Set 200-250-300 54071R0003 4 Evaporator Coil 100-150 54068R0004 4 Evaporator Coil 200-250-300 54071R0004 4 Coil Guard Grid 100-150 54068R0005 4 Coil Guard Grid 200-250-300 54071R0005

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5 Titanium Condenser Assembly 100 54068R0006 5 Titanium Condenser Assembly 150 54069R0001 5 Titanium Condenser Assembly 200 54071R0001 5 Titanium Condenser Assembly 250 54073R0001 5 Titanium Condenser Assembly 300 54075R0001 6 Spacer Assembly 100-150 54068R0007 6 Spacer Assembly 200-250-300 54071R0007 7 Single-Phase Compressor 100M 54068R0008 7 Single-Phase Compressor 150M 54069R0002 7 Three-Phase Compressor 150T 54070R0001 7 Single-Phase Compressor 200M 54071R0008 7 Three-Phase Compressor 200T 54072R0001 7 Single-Phase Compressor 250M 54073R0002 7 Three-Phase Compressor 250T 54074R0001 7 Three-Phase Compressor 300T 54075R0002 8 Condenser Draining Assembly 100-150 54068R0009 8 Condenser Draining Assembly 200-250-300 54071R0009 9 ABS Base 100-150 54068R0010 9 ABS Base 200-250-300 54071R0010 10 Flow switch All 54068R0011 11 Temperature and Defrost Sensor All 54068R0012 12 Water Temperature Sensor Cover All 54068R0013 13 Clamp Saddle for Temperature Sensor All 54068R0014 14 Clamp Saddle for Flow Switch All 54068R0015 15 Flow Switch Nipple All 54068R0016 16 High and Low Pressure Valve Core Assembly All 54068R0017 17 Feedthrough All 54068R0018 18 Valve Core Support Plate 200-250-300 54071R0011 19 Upright Post 100-150 54068R0019 19 Upright Post 200-250-300 54071R0012 20 Electrical Panel Gasket 100-150 54068R0020 20 Electrical Panel Gasket 200-250-300 54071R0013 21 Electrical Panel Cover 100-150 54068R0021 21 Electrical Panel Cover 200-250-300 54071R0014 22 Gas Line Cap 200-250-300 54071R0015 23 Permanent Capacitor 100M 54068R0022 23 Permanent Capacitor 150M 54069R0003 23 Permanent Capacitor 200M 54071R0016 23 Permanent Capacitor 250M 54073R0003 24 Power Board All 54068R0045 25 Single-Phase Contactor 100-150M 54068R0024

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
25 Three-Phase Contactor 150T 54070R0003 25 Single-Phase Contactor 200-250M 54071R0017 25 Three-Phase Contactor 200-250T 54072R0002 25 Three-Phase Contactor 300T 54075R0003 26 Fan Condenser 100-150 54068R0025 26 Fan Condenser 200-250-300 54071R0018 27 High Pressure Mini Switch All 54068R0026 28 Low Pressure Mini Switch All 54068R0027 29 High Pressure Gauge All 54068R0028 30 Drainage Stem 100-150 54068R0029 30 Drainage Stem 200-250-300 54071R0019 31 Expansion Valve All 54068R0030 31 Port 100 54068R0031 31 Port 150 54069R0004 31 Port 200 54071R0020 31 Port 250 54073R0004 31 Port 300 54075R0004 32 Filter-Drier B100-150 54068R0032 32 Filter-Drier B200-250-300 54071R0021 32 Reversible Filter-Drier R200-250-300 54081R0001 33 Display Rubber Gasket All 54068R0033 34 Digital Screen All 54068R0034 35 Keyboard All 54068R0035 36 Display All 54068R0036 37 Display Cover All 54068R0037 38 Starting capacitor 100-150M 54068R0038 38 Starting capacitor 200-250-300M 54071R0022 39 Transformer Optional 54068R0039 40 Reversing Valve R200-250-300 54081R0002 41 Servo reversing valve R200-250-300 54081R0003 42 Display Set B/R100-150 54068R0040 42 Display Set B/R200-250-300 54071R0023 43 Pool - Spa PCB Optional 54068R0046 44 Radio antenna All 54068R0047 45 Remote controller All 54068R0048 46 Starting relay 100-150M 54068R0044 46 Starting relay 200-250-300M 54071R0024

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
COPPER IRON PAPERCARDBOARD
STAINLESS STEEL WOOD ELECTRICAL MATERIAL
11.3. EXPLODED VIEW EXPLODED VIEW EXPLODED VIEW EXPLODED VIEW
See IMAGE 14 (page 192).
This unit has a refrigeration gas in liquid state and electrical components. When the heat pump reaches the end of its service life, it should be dismantled by an authorised company or it should be sent to the place selected by the local authorities.
With the aim of reducing the amount of electrical and electronic equipment residues and the danger of their components, to promote the recycling of the equipment and the appreciation of their residues, and to determine a suitable management that attempts to improve the effectiveness of the environmental protection, a series of regulations applicable to the manufacturing of the product and others related to the correct environmental management when they become residues have been implemented.

It is also envisaged to improve the environmental behaviour of all the agents involved in the service life of the electrical and electronic equipment, such as the producers, distributors, users, and, specially, those agents directly involved in the management of the residues derived from this equipment.
As of 13 August 2005, when you wish to throw away this unit, you have two possible return systems:
The units are labelled with the symbol of a “crossed out wheeled rubbish container “. This symbol denotes the need for its selective and differentiated collection from the rest of urban rubbish. Possible effects over the environment or human health of the dangerous materials it may contain.
PVC The most used plastifying agent in the different PVC applications is the DEHP (di-2-ethyl hexyl phthalate). The tests conducted in different laboratories demonstrate that it does not present risks for human health in the concentration levels so used in finished articles, according to the information from the German BUA (Advisory Body for the Relevant Environment of the Existing Substances) and the VGA (German Health Authority) among others. The results of these tests, together with the data collected in biodegradation studies, confirm that the DEHP cannot be considered dangerous for the environment. All additives used in the PVC formulations and therefore in the food industry applications are perfectly regulated at both European and Spanish level. In Europe, the EC Directive 90/128/EU, later modified by the 95/3/EU. In Spain, we should mention

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
the Royal Decrees 1125/1982 of 30 April 1982, later confirmed by the 1042/1997 of 27 June 1982. The service life analyses (SLA) demonstrate that the environmental impact of the PVC is equivalent or even more favourable than those corresponding to other materials.
TITANIUM Health effects Health effects Health effects Health effects. Elemental titanium and titanium dioxide are of a low order of toxicity. Humans overexposed to titanium dioxide via inhalation can develop slight changes in lungs. Effects of overexposure to titanium powder. Effects of overexposure to titanium powder. Effects of overexposure to titanium powder. Effects of overexposure to titanium powder. Dust inhalation may cause tightness and pain in chest, coughing, and difficulty in breathing. Contact with skin or eyes may cause irritation. Routes of entry: Inhalation, skin contact, eye contact. Carcinogenicity. The International Agency for Research on Cancer (IARC) has listed titanium dioxide within Group 3 (The agent is not classifiable as to its carcinogenicity to humans.) Environmental effects Environmental effects Environmental effects Environmental effects. Low toxicity. No negative environmental effects of titanium have been reported.
There is a 2-year warranty for all the parts. In the event of warranty cancellation:
The warranty will only have effect if the coupon is returned duly completed, sealed and signed by all interested parties.
1. WARRANTY COVERAGE 1. WARRANTY COVERAGE 1. WARRANTY COVERAGE 1. WARRANTY COVERAGE 1.1 In accordance with these provisions, the salesman guarantees that the product corresponding to this warranty (“the product”) does not present any non-conformance at the moment of its delivery. 1.2 The warranty period of the product is of two (2) years and it will take effect as of the time of delivery to the buyer. 1.3 If a Product non-conformance occurs and the buyer notifies it to the salesman during the Warranty Period, the salesman should repair or replace the Product at his own cost in the appropriate place, unless it is impossible or disproportionate. 1.4 When the Product cannot be repaired nor be replaced, the buyer shall be able to ask for a proportional price reduction or, if the non-conformance is sufficiently important, the discharge of the sales contract. 1.5 The replaced or repaired parts by virtue of this warranty will not extend the warranty term of the original Product, although they will have its own warranty. 1.6 For the effectiveness of this warranty, the buyer will have to credit the acquisition date and delivery date of the Product. 1.7 When the delivery of the Product to the buyer had been more than six months before and the buyer alleges non-conformance with the Product, the buyer will have to prove the origin and existence of the alleged fault. 1.8 The present Warranty Certificate does not limit or prejudges the rights the consumers are entitled by virtue of local prevailing and applicable regulations. 2. CONDITIONS TO WARRANTY 2. CONDITIONS TO WARRANTY 2. CONDITIONS TO WARRANTY 2. CONDITIONS TO WARRANTY

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
2.1 This warranty covers the products referred to in this manual. 2.2 For the effectiveness of this warranty, the buyer will have to strictly follow the manufacturer instructions included in the documentation enclosed with the Product, whenever this warranty is applicable according to the Product range and model. 2.3 When a calendar for the substitution, maintenance or cleaning of certain parts or components of the Product is specified, the Warranty will only be valid when the calendar has been observed. 3. LIMITATION TO LIABILITY 3. LIMITATION TO LIABILITY 3. LIMITATION TO LIABILITY 3. LIMITATION TO LIABILITY 3.1 This warranty will be solely applicable to those sales to consumers, being understood “consumers” as those people who acquire the Product with a purpose that does not fall within the scope of their professional activity. 3.2 No warranty is granted referred to the wear and tear caused by the use of the Product. In relation to the parts, components and/or consumable materials such as batteries, light bulbs etc., it will refer to the provisions of the documentation enclosed with the Product, when applicable. 3.3 The warranty does not cover those cases where the Product: (I) has been incorrectly treated; (II) has been repaired, maintained or manipulated by a non-authorized person, or (III) has been repaired or maintained with non-original pieces. 3.4 When the non-conformance of the Product is a consequence of an incorrect installation or start-up, this warranty will only cover those installations or start-ups included in the contract of sale of the Product and carried out by the salesman or under his/her responsibility.
Unit Reference No. Reference No. Reference No. Reference No. Model INSTALLER Name Town Address Telephone Start-up date up date up date up date USER Name Town Address Telephone Start-up date up date up date up date (To be filled by the (To be filled by the (To be filled by the (To be filled by the installer) INSTALLER’S STAMP: INSTALLER’S STAMP: INSTALLER’S STAMP: INSTALLER’S STAMP: For all units, this warranty will only have effect if this card is returned duly completed For all units, this warranty will only have effect if this card is returned duly completed For all units, this warranty will only have effect if this card is returned duly completed For all units, this warranty will only have effect if this card is returned duly completed

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
TABLE 2 TABLE 2 TABLE 2 TABLE 2

B100 B150 B200 B250 B300
230 II 230 II 400 III 230 II 400 III 230 II 400 III 400 III
N° ENGLISH CASTELLANO FRANÇAIS
SECTION [mm2] SECCION [mm2] SECTION [mm2]
N° OF WIRES N° DE CABLES N° DE FILS
N° DEUTCH ITALIANO PORTUGUES
QUERSCHNITT [mm2] SEZIONE [mm2] SECÇÃO [mm2]

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 1 IMAGE 1 IMAGE 1 IMAGE 1

N° ENGLISH CASTELLANO FRANÇAIS FILTRARION PUMP BOMBA FILTRACION POMPE DE FILTRAGE

DOSER / CHLORINATOR DOSIFICADOR / CLORADOR DOSEUR / CHLORINATEUR

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 2


MONOPHASIC ELECTRICAL CONNECTION MONOPHASIC ELECTRICAL CONNECTION MONOPHASIC ELECTRICAL CONNECTION MONOPHASIC ELECTRICAL CONNECTION
CONEXION ELECTRICA CONEXION ELECTRICA CONEXION ELECTRICA CONEXION ELECTRICA MONOFASICA MONOPHASÉE ALIMENTATION MONOPHASÉE ALIMENTATION MONOPHASÉE ALIMENTATION MONOPHASÉE ALIMENTATION EINPHASIGE ELEKTRISCHER ANSCHLUSS EINPHASIGE ELEKTRISCHER ANSCHLUSS EINPHASIGE ELEKTRISCHER ANSCHLUSS EINPHASIGE ELEKTRISCHER ANSCHLUSS
TRIPHASÉE ALIMENTATION DREIPHASIGE ELEKTRISCHER ANSCHLUSS
MONOFASE ALIMENTAZIONE MONOFASE ALIMENTAZIONE MONOFASE ALIMENTAZIONE MONOFASE ALIMENTAZIONE MONOFÁSICA ALIMENTAÇÃO MONOFÁSICA ALIMENTAÇÃO MONOFÁSICA ALIMENTAÇÃO MONOFÁSICA ALIMENTAÇÃO
IMAGE 3 IMAGE 3 IMAGE 3 IMAGE 3



N° ENGLISH CASTELLANO FRANÇAIS
FILTRATION PUMP CONTROL CONTROL BOMBA FILTRACION CONTROLE POMPE D´ÉPURATION
N° DEUTCH ITALIANO PORTUGUES

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 4 IMAGE 4 IMAGE 4 IMAGE 4




ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 5 IMAGE 5 IMAGE 5 IMAGE 5




ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM

ENGLISH ESPAÑOL FRANÇAIS DEUTCH ITALIANO PORTUGUES
SONDA TEMP. AGUA SONDE TEMP EAU SENSOR WASSER TERMERATUR
SONDA TEMP. AIRE AMBIENT SONDE TEMP AIR SENSOR LUFTTEMPERATUR
4-WAY VALVE VALVULA 4 VIAS VANNE A QUATRE VOIES 4-WEGE-VENTIL VALVOLA 4 VIE
AUX. EXTERNAL STOP PARO EXTERNO ARRET EXTERNE ZUSÄTZL EXTERNER STOP

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 6 IMAGE 6 IMAGE 6 IMAGE 6

INSIDE USER MENU: MOVE DOWN TO NEXT SCREEN
DANS LE MENU UTILISATEUR: PASSE À L'ÉCRAN SUIVANT. ENTERS USER MENU ENTRADA AL MENU USUARIO ENTRÉE DANS LE MENU
INSIDE USER MENU: MOVE UP TO PREVIOUS SCREEN OUTSIDE USER MENU: CHANGE OPERATION MODE, POOL, SPA, POOL & SPA
DENTRO MENU USUARIO: MUEVE A LA PANTALLA ANTERIOR FUERA MENU USUARIO: CAMBIA MODO OPERACIÓN, POOL, SPA, POOL + SPA
DANS LE MENU UTILISATEUR: PASSE À L'ÉCRAN PRÉCÉDENT EN DEHORS DU MENU UTILISATEUR: INTERCHANGE MODE DE FONCTIONNEMENT POOL, SPA, POOL & SPA
DANS LE MENU UTILISATEUR: MODIFIE LA VALEUR DU PARAMÈTRE EN DEHORS DU MENU UTILISATEUR: AUGMENTE LA CONSIGNE DE L'EAU. POWER ON / OFF AND ECO MODE ENCIENDE / APAGA & MODO ECO ON, ON ET ECO MODE
DANS LE MENU UTILISATEUR: MODIFIE LA VALEUR DU PARAMÈTRE À L'ÉCRAN EN DEHORS DU MENU UTILISATEUR: DIMINUE LA CONSIGNE DE L'EAU N° DEUTCH ITALIANO PORTUGUES
ALL'INTERNO DEL MENÙ UTENTE: VA A SCHERMATA SUCCESSIVA
ÖFFNET DAS BENUTZER MENÜ ACCESSO AL MENÙUTENTE ENTRADA NO MENU UTILIZADOR
IM BENUTZER MENÜ: ZURÜCK ZUM VORHERIGEN FENSTER AUSSER IM BENUTZER MENÜ: UMSCHALTEN ZWISCHEN DEN BETRIEBSARTEN POOL, SPA, POOL & SPA
ALL'INTERNO DEL MENÙ UTENTE: VA ALLA SCHERMATA PRECEDENTE. FUORI DAL MENÙ UTENTE: CAMBIA LA MODALITÀ DI FUNZIONAMENTO A PISCINA, SPA O PISCINA+SPA
DENTRO DO MENU UTILIZADOR: MOVE-SE PARA O ECRÃ ANTERIOR FORA DO MENU UTILIZADOR: ALTERA O MODO DE OPERAÇÃO PARA PISCINA, SPA OU PISCINA+SPA.
IM BENUTZER MENÜ: ÁNDERUNG DES WERTES DES IM DISPLAY ANGEZEIGTEN PARAMETERS. AUSSER IM BENUTZER- MENÜ: ERHÖHUNG DES SOLLWERTES FÜR DAS WASSER
ALL'INTERNO DEL MENÙ UTENTE: MODIFICA IL VALORE DEL PARAMETRO IN SCHERMATA FUORI DAL MENÙ UTENTE: AUMENTA LA TEMPERATURA TARGET DELL'ACQUA
DENTRO DO MENU UTILIZADOR MODIFICA O VALOR DO PARÂMETRO NO ECRÃ FORA DO MENU UTILIZADOR: AUMENTA A DEFINIÇÃO DA ÁGUA
UMSCHALTUNG ZWISCHEN DEN 3 BETRIEBSARTEN: ON, ON MIT ENERGIESPARMODUS UND OFF.
CAMBIA FRA LE 3 MODALITÀ DI FUNZIONAMENTO: ON, ON CON RENDIMENTO ENERGETICO E OFF.
MUDA PARA UM DOS 3 MODOS DE FUNCIONAMENTO: ON, ON COM RENDIMENTO ENERGÉTICO E OFF
IM BENUTZER MENÜ: ÁNDERUNG DES WERTES DES IM DISPLAY ANGEZEIGTEN PARAMETERS. AUSSER IM BENUTZER MENÜ: VERMINDERUNG DES SOLLWERTES FÜR DAS WASSER.
ALL'INTERNO DEL MENÙ UTENTE: MODIFICA IL VALORE DEL PARAMETRO IN SCHERMATA FUORI DAL MENÙ UTENTE: DIMINUISCE LA TEMPERATURA TARGET DELL'ACQUA.
DENTRO DO MENU UTILIZADOR: MODIFICA O VALOR DO PARÂMETRO NO ECRÃ FORA DO MENU UTILIZADOR: DIMINUI A DEFINIÇÃO DA ÁGUA

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 7 IMAGE 7 IMAGE 7 IMAGE 7

Working on pool’s water
Die Arbeit an Pools Wasser

Working on spa’s water
Trabajando en el agua de spa

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 8 IMAGE 8 IMAGE 8 IMAGE 8

Working on pool’s water
Die Arbeit an Pools Wasser

Working on spa’s water
Trabajando en el agua de spa

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 9 IMAGE 9 IMAGE 9 IMAGE 9



Spa filtration pump control Control bomba filtración spa Commande pompe filtr. spa Filterpumpensteuerung spa Controllo pompa filtrazione spa Controle da bomba filtracion spa


V1 V2 V3 TRANSFORMER TRANSFORMADOR TRANSFORMATEUR
TRANSFORMADOR TRANSFORMADOR TRANSFORMADOR TRANSFORMADOR

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 11 IMAGE 11 IMAGE 11 IMAGE 11



ENGLISH ESPAÑOL FRANÇAIS DEUTCH ITALIANO PORTUGUES
WATER TEMP TEMP AGUA TEMP EAU WASSERTEMPERATUR TEMP DELL´ACQUA
AIR TEMP TEMP AIRE TEMP AIR LUFTTEMPERATURE TEMP DELL´ARIA TEMP AR

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 13 IMAGE 13 IMAGE 13 IMAGE 13



EXT # EXT # EXT # EXT #2 EXT #1 EXT #1 EXT #1 EXT #1 EXT #1 EXT #1 EXT #1 EXT #1
POOL & SPA MODE MODO POOL & SPA MODE PISCINE & SPA
POOL & SPA MODUS MODALITÀPISCINA & SPA
MODALITÀ GENERALE
MODO GERAL
MODO POSCINA & SPA

ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
IMAGE 14 IMAGE 14 IMAGE 14 IMAGE 14








Declares under their own responsibility that all the heatpumps: ASTRALPOOLHEAT Manufactured since 31/07/2008, independent of the serial number, are in compliance with:
Machine safety directive 2006/42/EC. Electromagnetic compatibility directive 2004/108/EC and its modifications.
Low-voltage equipment directive 2006/95/EC. Directive 2000/14/CE concerning noise produced by equipment for outdoors use, as amended by Directive 2005/88/EC.
Restrictions in the use of certain risky substances in the electrical and electronic instruments 2011/65/EU (RoHS).
Relative to the electrical and electronic waste products 2012/19/UE (RAEE). Relative to the electrical and electronic instruments and the management of their waste products Spanish R.D. 208/2005
& 219/2013. The registration, the evaluation, the authorization and the restriction of the chemical substances EC Nº 1907/2006
(REACH) and amendment 126/2013 (REACH).
Declara bajo su única responsabilidad que todas las bombas de calor del tipo: ASTRALPOOLHEAT Producidas a partir del 31/07/2008, independientemente del número de serie, son conformes con:
Directiva de seguridad de máquinas 2006/42/CE. Directiva de compatibilidad electromagnética 2004/108/CE, y sus modificaciones.
Directiva de equipos de baja tensión 2006/95/CE. Directiva sobre el ruido producido por máquinas para uso exterior 2000/14/CE y su corrección con la Directiva
2005/88/CE. Directiva sobre restricciones a la utilización de determinadas sustancias peligrosas en aparatos eléctricos y electrónicos
2011/65/EU (RoHS). Directiva sobre residuos de aparatos eléctricos y electrónicos 2012/19/UE (RAEE). Real Decreto 208/2005 & 219/2013 sobre aparatos eléctricos y electrónicos y la gestión de sus residuos. Reglamento relativo al registro, la evaluación, la autorización y la restricción de las sustancias y preparados químicos CE Nº
1907/2006 (REACH) y su modificación 126/2013 (REACH). Déclare sous sa seule responsabilité que toutes les pompes à chaleur: ASTRALPOOLHEAT Fabriquées a partir du 31/07/2008, indépendamment du numéro de série, sont conformes avec:
Directive de sécurité de machines 2006/42/CE. Directive de compatibilité électromagnétique 2004/108/CE, et ses modifications.
Directive d’appareils de basse tension 2006/95/CE. Directive 2000/14/CE sur les émissions sonores du matériel destiné à l’extérieur, et sa correction à la directive
2005/88/CE. Directive relative à la limitation de l'utilisation de certaines substances dangereuses dans les équipements électriques et
électroniques 2011/65/EU (RoHS). Directive relative aux déchets d'équipements électriques et électroniques 2012/19/UE (DEEE). Espagnol Décret Royal 208/2005 & 219/2013 sur les équipements électriques et électroniques et la gestion de leurs
déchets. Règlement concernant l'enregistrement, l'évaluation et l'autorisation des substances chimiques, ainsi que les restrictions
applicables à ces substances (CE) nº 1907/2006 (REACH) et sa modifitation 126/2013 (REACH).
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.