Benutzeranleitung / Produktwartung Ventless Hood System FH-28 des Produzenten BKI
Zur Seite of 24
Ventless Hood System MODEL FH-28 Installation & Operation Manual Serial Numbers 123046 and higher.
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the origin al purc haser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship.
Ventless Hood System Table of Contents 1 T able of Content s Table of Contents .............................................................................................................. .......................... 1 Introduc tion ..................
Ventless Hood System Introduction 2 Introduction Congratulations! You have cho sen BKI ’s Ventless Ho od syste m, a state-of-t he-a rt unit that filters g rease laden air and returns it to the room.
Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from usin g this hood with a ny appliance that utilizes combustible fuel.
Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your e quipment. Keep all safety labels clean and in good con dition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Depart ment P.
Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electri cal co de s during installation of this unit could result in death, serio us inju ry or property damage.
Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375 ° F. (191 ° C.) Maximum shortening capacity 110 lbs. (50kg.
Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood d raws cooking vap ors through a grease baffle. Inside the b affle, the air reverses direction two times capturing p article s of moisture, grease, and dirt.
Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, alwa ys turn off ap pliance and allow time for it to cool before turning off the filter hood. This will in sure proper capture of gre ase vapors.
Ventless Hood System Installation 9 Inst allation Unpacking and Handling Inspection for Sh ipping Damage YOU are responsible for filing all freight claim s with th e delivering truck line. Insp ect all cartons and crate s for damage as soon as they arrive.
Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUI REMENTS). 2. Check for level from side to side and front to back u si ng a 4’ level placed appropriately on the frame.
Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and lev eled, secure to building by utilizing the .4 37 diameter holes provided in the rear of the fire extinguisher cylinder sh elf (Refer to figure below).
Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165 ° F fusible link must be installed in the dampe r assembly locate d at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook.
Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corne r, carefully slide the filter into the unit.
Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure bel ow. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not secu red to t he hood.
Ventless Hood System Installation 15 Fire Extinguishi ng Sy stem In the event of an appliance fire, seriou s injury, property damage or death could occur if any part of the appliance obstructs the spray n ozzles. Ensure that lids and/or other parts of the appliance do n o t obstruct the spray pattern of either nozzle.
Ventless Hood System Installation 16 3. If required, connect the provided fire extingui shing system contacts for remote signaling (refe r to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzl es as depicted b elow.
Ventless Hood System Installation 17 The fire extinguishing system must be o perative before the electrical system will function. Refer to the electrical diagram included i n attached to this unit or in the servi ce manual.
Ventless Hood System Installation 18.
Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for ap pli ances requiring a UL listed flexible conduit connections (refer to figure below). 1. Remove receptacle and fo ur wires (T1, T2, T3, and Grou nd). 2. Cover junction box hole with provided pl ate and hardware removed from re ceptacle.
Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed d own wit h water. This unit is NOT designed for hose wash -d own cleaning! Refer to sch eduled maintenance b elow for proper hood cleaning. Electrocution could occur if powe r is not removed from this unit before servicing.
Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining fr ame at the top of the grea se baffle. 3. With one hand, hold the baffle to prevent it from dropping. With the other hand, lo ose n the thumbscrews and slide the retaining frame forward.
P.O. Box 80400, Simpsonvill e, S.C. 29680-0400, USA http://www.bkideas.co m Made and printed in t he U.S.A LI0114/0 407.
Ein wichtiger Punkt beim Kauf des Geräts BKI Ventless Hood System FH-28 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie BKI Ventless Hood System FH-28 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für BKI Ventless Hood System FH-28 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von BKI Ventless Hood System FH-28 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über BKI Ventless Hood System FH-28 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon BKI Ventless Hood System FH-28 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von BKI Ventless Hood System FH-28 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit BKI Ventless Hood System FH-28. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei BKI Ventless Hood System FH-28 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.