2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%,:4/-3 )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE 2EADANDSAVETHESEINSTRUCTIONS W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE.
)MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSERVE THE FOLLOWING: a. Installation worka nd electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards.
CONTENTS INSTALLA TION Mount heights & clearance Ducting Specifications Electrical Mounting the hood EZ Anchors Ductless Conversion Carbon Filters 1 1,2,3 4 4 5,6 6 7 7 8 8 8,9 8,10 11 12 13 FEATU.
!MINIMUMOFROUNDORX RECTANGULARDUCTMUSTBEUSEDTOMAINTAIN MAXIMUMAIRFLOWEFFICIENCY !LWAYSUSERIGIDTYPE.
INST ALLA TION 2 DUCTING NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
INST ALLA TION DUCTING 6" to 3-1/4 x 10" elbow adaptor. Air Diverting Kit Air register Ductless Re-circulating option Ductless Re-circulating option Crawl space 3.
INST ALLA TION SPECIFICATIONS ELECTRICAL Cable Lock WARNING: All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation.
Mounting the Range Hood 1. Mark hood center on Center hood on wall. 2. Mark and Install Wall Mount Bracket to Wall. (For hollow drywall, use E-Z Anchors, please see next page) 3.
INST ALLA TION INSTALLA TION EZ ANCHORS Tap EZ anchor tip into marked drywall locations, turn with screwdriver until seated flush. Note: Whenever possible, the hood should be secured to wall studs. Use EZ anchors provided only on hollow drywall applications (minimum drywall thickness ½”).
#ARBON&ILTERS2EQUIRED 0URCHASEDUCTLESS#HARCOAL&ILTERSAS FOLLOW 2EMOVEMETALFILTERSONHOOD#LIP CARBONFILTERSONTOEACHSLOTO.
Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3. Speed Selection The 6 speed levels are selected by pressing to decrease and to increase speed level. The display indicates level selected.
FEA TURES & CONTROLS CONTROLS: FILTER CHANGE INDICA TOR (Carbon Filters) Filter Change Reminder (Carbon, if fitted): When your hood is installed as a 'Purifying' (Ductless Recirculating) unit, it is fitted with a set of Carbon Filters to purify exhaust and fumes from cooking, and re-circulates the air within the home.
FEA TURES & CONTROLS CONTROLS: FILTER CLEAN INDICA TOR (Metal Filters) Filter Clean Reminder (Standard Metal Filters fitted) Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are fitted by the factory. These Metal Filters are intended to filter out residue from cooking.
-!).4%.!.#% #,%!.).' 3URFACE-AINTENANCE #LEANPERIODICALLYWITHHOTSOAPYWATERANDCLEANCOTTONCLOTH$ONOTUSECORROSIVEOR ABRASIVEDETERGENT.
MAINTENANCE LIGHTS Make sure all power is turned off and bulbs are not hot. Carefully pry trim (w/ glass) off the socket module. Replacement bulb w/ 12V 20W type bulbs. Replacing Light Bulbs CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled.
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to .
4//"4!).3%26)#%5.$%27!22!.49 ORANY3ERVICE2ELATED1UESTIONSPLEASECALL (AVEYOURPRODUCTPROOFOFPURCHASE.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr ZTO-M795 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr ZTO-M795 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr ZTO-M795 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr ZTO-M795 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr ZTO-M795 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr ZTO-M795 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr ZTO-M795 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr ZTO-M795. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr ZTO-M795 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.