Benutzeranleitung / Produktwartung EOT-E42ASX des Produzenten Zephyr
Zur Seite of 22
www .zephyronline.com Guide dutilisation, dentretien et dinst allation Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de mod.
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALL A TION MUST COMPL Y WITH A LL LOCAL CODES. IMP ORT AN T : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner.
3 www .zephyronline.com T able of Content s Important safet y Notic e ..................................................................... 4 Electrical & Installa tion requi rements .............................................. 5 Electrical req uirements .
4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer .
5 www .zephyronline.com Electrical & Installation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer s responsibility: T o co ntact a qualified electrical inst al le r .
6 List of Materials PARTS SUPPLIED: Blower unit housing Hood canopy Met al filter x 1 Halogen light bulb x 4 Upper and lower Duct covers x 4 Chimney structure Hardware Pack.
7 www .zephyronline.com Dimensions and clearances.
8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any ev entual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting version ).
9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4 x 10 Rect., straight 6 Round,, straight 7", 8 Round,, straight 3 1/4 x 10 Rect.90° elbow 3 1/4 x 10 Rect.45° elbow 3 1/4 x 10 Rect.90° flat elbow 3 1/4 x 10 Rect.
10 1. Pre-installation calculations 1" 3/8 K C (36" std) P S H a) Select a hood preference height P that is comfort able for the user . (from 24 to 32).
11 www .zephyronline.com c. Install a 8 exhaust duct and extend length = S - 16 5/8 from ceiling. Duct shall be securely fastened to joist s. Do not use duct smaller than specified. Attention: Duct inst allation is not required for non- vented (recirculating) inst allations d.
12 8. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE.
13 www .zephyronline.com d. Fasten the canopy with 1 1 screws from the bottom. Bottom Vie w FRONT FRONT FRONT 12. Fix 6 nuts on the internal side of top duct covers sections (squere slots) and fix each other with 6 screws (3 per side). Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13.
14 14. Fix 6 nuts on the internal side of rear bottom duct covers section (square slot s - see drawings afte r step 1 1) and place it on the rear side of the hood on top the canopy , cheack that it snaps with top duct covers assembly . rear bottom duct covers section Plan diagram top view rear bottom duct covers section (snap into place) 15.
15 www .zephyronline.com 17. Assemble the lower (narrow) trim strips to the lower vent cover assembly . Cut the upper (wide) trim strips to length to fit the upper duct cover assembly . Assemble the upper trim strips to the upper duct cover assembly .
16 Description of t he hood & Controls 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps m ay v ar y) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) CONTROLS Use the high suction speed in cases of concentrated kitchen vapours.
17 www .zephyronline.com Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents.
18 T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON.
19 www .zephyronline.com W arranty T O OBT AIN SERVICE UNDER WARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obt ain ser vic e under the warranty . T O OB T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date.
20 List of Part s and Accessories Part Description Part# halogen bulb, 12V 20 W metal filter Part Description Part# Ductless recirculating kit charcoal replacement filter duct cover extension kit inte.
21 www .zephyronline.com.
22.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr EOT-E42ASX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr EOT-E42ASX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr EOT-E42ASX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr EOT-E42ASX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr EOT-E42ASX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr EOT-E42ASX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr EOT-E42ASX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr EOT-E42ASX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr EOT-E42ASX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.