Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ N.
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local Electrical Inspector ’ s use. INST ALLER: Please leave these Instructions with this unit for the owner .
3 www .zephyronline.com T able of Content s Important Safety Notice .................................................................... 5 Electrical & Installation Requirements ............................................ 6 Electrical requirements .
4 Installation - Installing the Duct Covers ......................................... 18 Installation - Hanging the Hood onto the Wall .............................. 19 Installation - Electrical Connection & Final Installation Steps ..... 20 Electrical connection .
5 www .zephyronline.com Import ant Safety Notice CAUTION FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE T O EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
6 Electrical & Inst allation Requirement s ELECTRICAL REQUIREMENTS IMPORT ANT Observe all governing codes and ordinances. It is the customer’s responsibility: T o cont act a qualified electrical inst aller .
7 www .zephyronline.com List of Materials P ARTS SUPPLIED • Hood body , with st ainless steel baf fle filter a nd halogen light bulbs and incandescent lamp already inst alled • T wo telescopic duct covers and support bracket • Hardware Packet: - 24x53 T1T2 "L" Male monkey spanner (1 piece) - 3.
8 Dimensions and Clearances Only for version with top discharge feature: * Hood with external motor: Over this measurement a hole may be made on the rear section for the passage of the discharge pipe for connection to the external motor. Consult the template for the passage of pipes under this measurement .
9 www .zephyronline.com Ducting Options and Examples Closely follow the instructions set out in this manual. All responsibility , for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.
10 Inst allation - Ductwork Calculation Sheet 3 1/4 ” x 10” Rect., straight 6 ” Round,, straight 7", 8” Round,, straight 3 1/4 ” x 10” Rect.90° elbow 3 1/4 ” x 10” Rect.45° elbow 3 1/4 ” x 10” Rect.90° flat elbow 3 1/4 ” x 10” Rect.
11 www .zephyronline.com Inst allation - Preliminary Operations Attention! The installation requires several steps where is asked to temporarily remove some particulars and screws, We recommend to record and keep all of these components in a safe place ready to be used as required.
12 Inst allation - Internal Blower Note: for External blower installation disregard the instruction in this page and step ahead on page 14. TOP DISCHARGE (V ertical discharge) The hood is ready to be used for vertical discharge, proceed to install the internal blower (See next page).
13 www .zephyronline.com INTERNAL BLOWER INST ALLA TION • Fit the blower inside the hood. • Install the blower to the support with 4 screws (Provided), check that the rectangular outlet of the blower matches with the rectangular slot of the support.
14 • Install the supplied round transition collar to the previously installed cover/round transition support plate from inside the hood. Align and att ach with 2 screws securely .
15 www .zephyronline.com • Install the supplied round transition collar to the previously installed cover/round transition support plate. Align and att ach with 2 screws securely . EXTERNAL BLOWER ELECTRICAL CONNECTION - PRELIMINAR Y OPERA TIONS Installing the external blower junction box • Remove the electrical knock out on the upper panel.
16 • T o att ach front p anel to hood body , align the 8 threaded studs through the front bodies corresponding holes. Use 8 wing nuts to attach and secure. See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Inst allation - Front Panel NOTE: The front p anel is not supplied with the range hood and must be purchased sep arately .
17 www .zephyronline.com Inst allation INST ALLING THE HOOD ONT O THE W ALL 1. Disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Use a thick, protective covering over countertop, cooktop or range to protect from damage and debris.
18 13. Optional duct cover installation: a. Remove the support bracket from the Duct Cover assembly and attach it to the ceiling with 2 drywall anchors and screws Note: The printed index on the bracket must match the center line previously drawn (See installation step 2 ).
19 www .zephyronline.com Inst allation - Hanging the Hood onto the W all 14. For internal blower inst allation ONL Y : a. Horizontal (Rear) discharge: Install from the outside the 3 1/4 ” x 10” Rect. transition on the outlet hole of the blower with 3 screws.
20 Inst allation - Electrical Connection & Final Inst allation S tep s 18. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service p anel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required.
21 www .zephyronline.com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5.
22 Features & Controls - T ouch Controls & Features Use the high suction speed in cases of concentrated kitchen vapors. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes after terminating cooking.
23 www .zephyronline.com Filter Clean Reminder (Standard Baffle Filters fitted): A set of baf fle filters are fitted by the factory . These Baf fle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
24 Maintenance BAFFLE FIL TER This must be cleaned once a month using non abrasi- ve detergent s, either by hand or in the dish-washer , which must be set to a low temperature and a short cycle. When washed in a dish-washer , the baf fle filter may discolor slightly , but this does not af fect it s filtering cap acity .
25 www .zephyronline.com Maintenance REPLACING THE MOOD LIGHTING BULB: T o replace mood lighting bulb, remove baf fle filter from hood. T o access lamp area, remove the two threaded knobs that fix the cover . Unscrew mood lighting bulb counter-clockwise and replace with a st andard max.
26 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal filter is vibrating. 1. The power source is not turned ON.
27 www .zephyronline.com List of Part s and Accessories Part Description Part# Internal Blower 600 CFM External Blower 1000 CFM Halogen Bulb, 120V 50 W Filter Baffle Z0B0020S EBI-600B CBE-1000 Front P.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr CPA-E42ASX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr CPA-E42ASX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr CPA-E42ASX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr CPA-E42ASX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr CPA-E42ASX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr CPA-E42ASX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr CPA-E42ASX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr CPA-E42ASX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr CPA-E42ASX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.