Benutzeranleitung / Produktwartung COK-E36SX des Produzenten Zephyr
Zur Seite of 23
Okeanito C O K -E36SX C O K-E42SX C O K -E48SX U s e , C a r e , a n d I n s t a lla t ion G u id e MAY07.0101 ww w .zephyronline.com Model number: Serial number: Date of Purchase: Sales Dealer: © Zep hyr Corpo ration.
www .zephyronline.com.
Ta b l e o f C o n t e n t s 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance .
www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R E D U C E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L ID- S T A TE SP E E D CONTRO L DE V I C E . TO R E DU C E T H E R IS K O F F I R E, E L E C T R I C SH O C K, O R INJ U R Y T O P E R S ON S, O B S E RVE T H E FO L LO W I N G: a.
Li s t of M a t e r ia l s 3 MODEL: COK-ExxS 1 - Hood 1 - Bae Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs G U-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - T elescopic Duct Co.
www .zephyronline.com 4 I ns t a lla t io n - Duct wo rk C a lcula t io n S he e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect.
5 I ns t a l l a t i o n - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 36" M in 96"-Max 124 ” M in 28"-Max 36" Min 32"-Max 52" 14 1/2" Minimum mount height between range top to hood bot- tom should be no less than 28".
Installation - Ducting www .zephyronline.com side wall cap with gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 6 Soffit or crawl space External Blower External Blower W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages.
7 I n s t a lla tion - Sp ec ific at ion s R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 / 4” 19 3/4” 10” 36” , 42” , 48 ” 22 5 / 8” 11 7 / 8” 95 ° 16 5/8” 13 3 / 8” 14 1 / 2.
www .zephyronline.com I ns t a lla t io n - In t e r n a l B l ow e r 8 The internal blower kit consists of the blower and capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to ange as shown using the provided 1/2” 5x15mm screws with washers.
I n s t a lla tion - I n te r n al B lower 9 5. Remove existing grounding screw and att ach grounding wire from capacitor bo x. 6. Re-attach grounding screw to nish installation of capacitor box. Refer to Fig-A on previous page. 7 . Attach short capacitor connector to blower connector.
www .zephyronline.com 10 I ns t a lla t io n - P re p a ring E xt e rn a l B lo we r The external blower kit consists of an 8” collar , and external blower wiring box. T he external blower is purchased separately . A T TE NTI O N The following are intructions on preparing your hood for installation with e xternal blower model CB E-1000.
11 6. Position cover onto external blower wiring box. 7 . Secure cover to box with provided screw . 8. Attach connector from external blower wiring bo x to control board box connector inside hood. 9. Attach grounding wire from external blower wiring bo x to grounding screw of the junction bo x.
A B min 28” max 36” C/L C/L 14 1/2” Duct Cover Ceiling Bracket 7 1/2” Attach screws to ceiling bracket C/L C 21” Duct Cover Ceiling Bracket www .zephyronline.com 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line.
13 In s t a l l a t i on - Mo u n t i n g H o o d gap between bracket and wall To p Bottom 1. Place wall brac ket on line C. P osition t o p of wall brac ket so it is even with the 21” mounting spread. Make sure bracket is atta c hed to wall as shown in the diagram.
www .zephyronline.com 14 I ns t a lla t io n - A t t a c hing U t e ns il R a il 1. Attac h utensil rail to hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is lined up with the hole, gently slide the rest of the rail onto the canopy .
15 2 3 4 6 1 5 The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard.
16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. T hey need not be replaced on a regular basis but are required to be kept clean.
17 M a i n t e n a n c e - C l e a n i n g S urface M aintenance : C l ean p eriodicall y w i t hh ot s oap y wate r a n d c l ean cotto n c l ot h . Do n ot use co rr os iv e o r ab r as iv e deter g en t , o r stee l woo l /scourin g p a ds whi c i i h will s cra t c h an d d amag e surface .
18 Replacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T tou c h bulbs until swit c hed o and cooled. T ouc hing hot bulbs may cause serious burns.
19 T ro uble S ho o t ing After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working.
20 www .zephyronline.com Part Desc r iption P art# Halogen Bulb G U-10, 120V, 50W Z0B-0020 Incadescent Bulb T29 127V 40 W Z0B-0003 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 D.
www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr COK-E36SX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr COK-E36SX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr COK-E36SX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr COK-E36SX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr COK-E36SX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr COK-E36SX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr COK-E36SX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr COK-E36SX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr COK-E36SX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.