Benutzeranleitung / Produktwartung APN-M90ABX des Produzenten Zephyr
Zur Seite of 20
ww w .zeph yronline .com Plane APN-M90ABX APN-M90A WX RANGE HOOD - Installation instructions.
ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 21 CAMP ANA EXTRACT OR A - Manual de utilización ...P ag. 41 CAPP A ASPIRANTE - istruzioni per l’uso .
C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS .............................................................................................
ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspec tors use . INST ALLER : Please leave these Instructions with this unit for the owner .
settings. B. Always turn hood ON when c ook ing at high heat or when ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or lter .
ww w .zeph yronline .com through the ue (chimney) of fuel burning equipment to prev ent back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those.
(1+1) M4 (12) 1/4" Duct Covers Cont rol Electrical Junction Box Duct Cover Bracket Glass Light Bulbs Decorative Mesh F ilters Range Hood Body List of Materials - 7 -.
ww w .zeph yronline .com Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet.
Hood Speci cations front of hood side of hood top of hood - 9 -.
ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of re and electric shock, install this range - hood only with internal blow er models MT -017 provided with the kit cod CBI-600A.
6. Attach the 6 pin male molex connector from blo wer wire to the 6 pin f emale molex connec tor located inside the blower housing . See Fig .6 7. Install blower and blow er plate into blo wer housing by f ollowing the rev erse instruc tions from step 2.
ww w .zeph yronline .com The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of re and electric shock, install this rangehood only with r emote blow ers ra ted maximum 6.
6. Inser t the 6 pin female molex connector into the junction box. See F ig. 6A. Secure r emote blower junction box to top of blo wer housing using (2) screws . S ee F ig. 6B 7. F eed remote blo wer wir e harness through r emote blower junction box c ov er and Connect the wires with those inside the junction box.
ww w .zeph yronline .com W ARNING FIRE HA ZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only .
Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum eight of 24 inches (71cm) from the cooking sur face. If a connecting duct work composed of two par ts is used, the upper part must be placed outside the low er par t.
ww w .zeph yronline .com GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y CONNECTION F or connec tion to the po wer supply ref er to the follo wing: 1.
MOUNTING THE DUCT CO VER 1. Install the elec trical wiring and test hood f or functions prior to installing the duc t co vers . 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers . See the manual included with the recir culating k it f or more instructions.
ww w .zeph yronline .com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors.
List of P ar ts and A c cessories DESCRIPTION HOOD P ART# REPLA CEMENT P ARTS Light Bulb GU4, 20W (each) APN Z0B0030 OPTIONAL A CCESSORIES Recirculating Kit APN ZRC-00PN Replacement Char coal F ilt ers APN Z0F-00A C Duct Cover Extension APN Z1C-00PN T o order parts, visit us online at http://store .
ww w .zeph yronline .com - 20 -.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr APN-M90ABX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr APN-M90ABX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr APN-M90ABX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr APN-M90ABX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr APN-M90ABX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr APN-M90ABX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr APN-M90ABX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr APN-M90ABX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr APN-M90ABX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.