Benutzeranleitung / Produktwartung AK8800AS des Produzenten Zephyr
Zur Seite of 17
Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © 2008 Zephyr Corporation W illow AK8800AS AK8800AG READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA.
www .zephyronline.com.
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance .
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY T O PERSONS, OBSERVE THE FOLLOWING: a.
Important Safety Notice 3 CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place.
List of Materials 4 www .zephyronline.com MODELS: AK8800AS AND AK8800AG P ARTS SUPPLIED 1 - 316S High quality stainless steel Power Pack (AK8800AS) or 1 - Gray powder coated Power Pack (AK8800AG) 2 - .
5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft.
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 8” round ducting must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%.
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape.
8 www .zephyronline.com Installation – Speci fi cations top side front C L 11 7/16 ” 13/16” 2 5/8 ” 14 11 / 1 6 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 1 5/16 ” 1 1/2 ” C L elec.
9 ELECTRICAL W ARNING All Electrical work must be performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
10 www .zephyronline.com Installation – Installing the Power Pack Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. (FIG 3) 2. Install optional AK088xAS Stainless Steel Liner under custom hood opening.
11 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower.
12 www .zephyronline.com Maintenance – Cleaning and Installing Filters SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface.
13 Maintenance – Lights REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot.
14 www .zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR WILLOW Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2.
List of Parts and Accessories 15 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210010 Optional Accessories Liner , 36” AK0886AS Liner , 42” AK0882AS Liner , 48” AK0888AS Liner , 54” AK0884AS Liner , 60” AK0880AS T o order parts, visit us online at http://store.
Ein wichtiger Punkt beim Kauf des Geräts Zephyr AK8800AS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr AK8800AS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr AK8800AS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr AK8800AS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr AK8800AS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr AK8800AS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr AK8800AS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr AK8800AS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr AK8800AS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.