Benutzeranleitung / Produktwartung AK8200AS des Produzenten Zephyr
Zur Seite of 22
Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: JUL1 1.0601 © 2010 Zephyr Corporation T ornado II AK8200AS T ornado III AK8300ASX .
www .zephyronline.com.
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance .
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a.
Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
List of Materials 4 www .zephyronline.com MODELS: AK8200AS AND AK8300ASX P ARTS SUPPLIED AK8200AS AK8300ASX 1 - Power Pack 1 - Power Pack 2 - Baffl e fi lters 3 - Baffl e fi lters 2 - Halogen ligh.
5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft . x ( ) = Ft.
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow effi ciency for single blower and 8” round duct for dual and remote blowers.
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver T ape or Duct T ape.
8 www .zephyronline.com Installation – Specifi cations C L 11 7/16 ” 13/16” 2 5/8 ” 14 1 1/16 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 4 3/4 ” 11 7/16 ” 1 5/16 ” 6 1/2 ” 1 1/2 ” C L elec.
9 ELECTRICAL W ARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
10 www .zephyronline.com Installation – Installing the Power Pack 1. Install blower into Power Pack AK8200AS - Blower is pre-installed AK8300ASX - Refer to page 1 1 for instructions Remove support screw from top of Power Pack before installing into cabinet.
11 MUL TIPLE BLOWERS ARE COMP A TIBLE WITH AK8300ASX ONL Y . AK8200AS INCLUDES A 1000 CFM DUAL BLOWER ONL Y . FOR REMOTE BLOWER PREP ARA TION INSTRUCTIONS TURN TO P AGE 12. 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws.
12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. Connect 8” round duct work to 8” round adapter . 2. Install threaded end of remote blower wiring through external blower wiring knock out (B) located in junction box on top of power pack.
13 F The standard baffle filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possible clog duct work and create a fire hazard.
Features & Controls – T ouch Controls 14 www .zephyronline.com B a ffl e Filt er Cl ean R em i n d er Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory , These baffle filters are intended to filter out residue from cooking.
15 FCC Caution: T o assure continued compliance, any changes or modifi cations not expressly approved by the party responsible for compliance could void the user ’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device.
Maintenance – Cleaning and Installing Filters 16 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface.
17 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise.
T roubleshooting 18 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON.
19 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baffl e Filter (each) 50210010 Remote Control 14000005 Optional Accessories Liner ,36” (AK8200AS) AK0806AS Liner .
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to .
Ein wichtiger Punkt beim Kauf des Geräts Zephyr AK8200AS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Zephyr AK8200AS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Zephyr AK8200AS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Zephyr AK8200AS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Zephyr AK8200AS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Zephyr AK8200AS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Zephyr AK8200AS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Zephyr AK8200AS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Zephyr AK8200AS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.