Benutzeranleitung / Produktwartung Summit Built-In NG Side Burner des Produzenten Weber
Zur Seite of 12
SUMMIT ® # 42377 42377 US 01/18/06 NG YOU MUST READ THIS O WNERS GUIDE BEF ORE OPERA TING YOUR G A S GRILL BUILT-IN NG SIDE BURNER INST ALLA TION/ OWNER'S GUIDE Summit ® Built-In NG Side Burner THESE ACCESSORIES MA Y BE PURCHASED SEP ARA TEL Y .
2 DANGERS & W ARNINGS DANGER Failure to follow the Dangers, W arnings and Cautions contained in this Owner ’ s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property . W ARNINGS Do not store a spare or disconnected liquid propane cylinder under or near this barbecue.
3 W ARRANTY W ARRANTY Weber-Stephen Products Co. (W eber) hereby warrants to the ORIGINAL PURCHASER of this Weber ® gas grill that it will be free of defects in material and workmanship from the date of purchase as follows: when assembled and operated in accordance with the printed instructions accompanying it.
4 L OCA TING YOUR BUIL T -IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installa- tion, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible.
5 MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner . TEST CONNEC TIONS All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.
6 GAS INSTRUC TIONS T able 10-1 Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch W ater Column. (Based on a 0.60 Specifi c Gravity Gas) Nominal Iron Pipe Size (Inches) Internal Diameter (Inches) Length of Pipe (Feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 1/4 .
7 Regulator Hard piped gas supply top view Figure 1 Cap (Optional Side Burner) Regulator to side burner Hard piped gas supply top view Figure 2 CONNEC T GAS SUPPL Y 1) Uncap the fl are fi tting from the optional side burner connection located at regulator .
8 GAS INSTRUC TIONS TOSIDE BURNER TOREGULATOR TOPVIEW Check: 1) Corrugated gas line-to-Accessory “T” Connection. 2) Main gas Supply to regulator W ARNING: If there is a leak a connection(1), retighten the fi tting with a wrench and recheck for leaks with soap and water solution.
9 (1) (2) (3) OPERA TING / MAINTENANCE MANU ALL Y LIGHTING THE SIDE BURNER DANGER Failure to open the lid while igniting the side burner , or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death.
10 SIDE BURNER MAINTENANCE W ARNING: All gas controls and supply valves should be in the OFF position. Make sure wire is connected between the igniter and electrode.
11 A TTENTION: This product has been safety tested and is only certifi ed for use in a specifi c country . Refer to coun- try designation located on outer carton. These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co.
©2003 The following trademarks are registered in the name of W eber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067 U.
Ein wichtiger Punkt beim Kauf des Geräts Weber Summit Built-In NG Side Burner (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Weber Summit Built-In NG Side Burner noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Weber Summit Built-In NG Side Burner - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Weber Summit Built-In NG Side Burner reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Weber Summit Built-In NG Side Burner erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Weber Summit Built-In NG Side Burner besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Weber Summit Built-In NG Side Burner verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Weber Summit Built-In NG Side Burner. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Weber Summit Built-In NG Side Burner gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.