Benutzeranleitung / Produktwartung 24 VDC des Produzenten Beckett
Zur Seite of 16
Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Notice Special Requirements............................................. 3 Speci fi cations ..................
3 24 Vdc SDC Burner Manual Notice Special Requirements If you discover damage to the burner or controls during unpacking, notify the carrier at once and fi le the appropriate claim. When contacting Beckett for service information — Please record the burner serial number (and have available when calling or writing).
4 T able 1. Combustion Head Firing Rates Firing Rate GPH (min - max) Head 1.75 - 3.25 F22/F220 2.50 - 5.50 F310 Section: General Information & Nozzle Assembly Maintenance Adequate V oltage Require.
5 24 Vdc SDC Burner Manual Section: Nozzle Assembly Maintenance Correct Nozzle and Flow Rate Required Incorrect nozzles and fl ow rates could result in impaired combustion, under- fi ring, over- fi ring, sooting, puff-back of hot gases, smoke and potential fi re or asphyxiation hazards.
6 Figure 5. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance The Beckett Z gauge (part number Z- 2000) is available to permit checking the F head “Z” dimension without removing the burner .
7 24 Vdc SDC Burner Manual A. Connect Fuel Lines For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard.
8 Section: Burner Wiring Explosion, Fire, Scald, & Burn Hazard All heating equipment must have HIGH LIMIT controls to protect against excessive temperature and/or pressure. The control must interrupt electrical power and shutdown the burner , if operating or safety controls fail and cause a runaway condition.
9 24 Vdc SDC Burner Manual Section: Drive Component Maintenance Driv e Component Maintenance A. Motor , Blower Wheel, & Coupling Replacement The motor will require replacement if the proper voltage is measured at the motor input, and the motor will either not run, or the current draw with a free running pump exceeds 10% of the rated current.
10 Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards.
11 24 Vdc SDC Burner Manual Section: Maintain & Service Burner Maintain & Ser vice Bur ner A. Owner ’ s Information Have your equipment inspected at regular intervals by a quali fi ed service agency to assure continued proper operation. The burner should be adjusted using dedicated combustion test equipment.
12 T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling.
13 24 Vdc SDC Burner Manual Section: T roubleshooting T able 3. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities.
14 R eplacement P ar ts Section: Replacement Parts 21 20 14 15 19 17 16 13 12 10 9 8 4 5 6 7 3 2 1 22 18 11 * ‘ X ’s indicate timing options. Contact Beckett for available part numbers.
15 24 Vdc SDC Burner Manual.
The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship.
Ein wichtiger Punkt beim Kauf des Geräts Beckett 24 VDC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Beckett 24 VDC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Beckett 24 VDC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Beckett 24 VDC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Beckett 24 VDC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Beckett 24 VDC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Beckett 24 VDC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Beckett 24 VDC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Beckett 24 VDC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.