Benutzeranleitung / Produktwartung BFC36 des Produzenten Vermont Castings
Zur Seite of 24
647 BFC cover 8/18/00 djt BFC Balance Flue (Closed Combustion) Heat-Circulating Fireplace Model: BFC36 For use in the U.S. / Canada Underwriter ’s Laboratories Report No.
2 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty .
3 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC36 Balanced Flue Heat-Circulating Fireplace Fig. 1 BFC36 specifications and framing. " (16mm) " (13mm) .
4 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Standoff .
5 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet.
6 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
7 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m).
8 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig.
9 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required.
10 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ ” (38mm), al- lowing the remainder to extend in front of firebox.
1 1 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together .
12 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard.
13 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas).
14 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 MA81 rev. 8/5/97 1 ¹⁄₂ " Ref. B C Combustible materials are permitted within a shaded area shown in Figure 21 titled Minimum W all Clearances. * * * MA81 Fig. 20 Combustible mantel clearances.
15 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with CFM Corporation W all Shield Model SP40 or a specifically built wall shield described in Figure 18.
16 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model.
17 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Finish Glass Doors The fallaway handles are used to open and close the front doors. The fallaway handles may be removed after each use or may be left in place. CAUTION: If the handles are left in place during operation, they may become hot.
18 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Install 1/2” (13mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe.
19 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 647 BFC parts 8/24/00 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 � 24 25, 26 20 21, 22, 23 27 27 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC Balanced Flue Fireplace (continued) 25. Stud 3/8-16 x 1 ⁵⁄₈ ” 20009776 26. Nut Hex Jam 3/8-16 T oplk 1203290 27.
21 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 The following accessories for this appliance are available from your local V ermont Castings, Majestic Products dis- tributor . Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd.
22 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ .
23 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its Pre-En.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Ein wichtiger Punkt beim Kauf des Geräts Vermont Castings BFC36 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Castings BFC36 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Castings BFC36 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Castings BFC36 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Castings BFC36 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Castings BFC36 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Castings BFC36 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Castings BFC36. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Castings BFC36 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.