DO NOT ST ORE OR USE GASOLINE OR OTHER FLAM- MABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
2 Dutchwest Direct V ent / Natur al V ent Gas Heater 30001935 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 General Information The Dutchwest Direct V ent/Natural V ent Room Heater , Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.
4 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Dutchwest Direct V ent / Natural V ent Dimensions C L V alve Inlet 23" (584mm) 6 " (172mm) 24 " (622mm) .
5 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude.
6 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natural V ent ST128b Stardance flue centerline 9/28/00 djt C L C L B D C A ST128c Stove Clearances A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines C: 15 ¹⁄₂ ” (395 mm) D: 9” (229 mm) Fig.
7 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 2465 Nat Millivolt 28,000 20,000 2466 Prop Millivolt 28,000 19,000 Gas Specifications Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minimum 5.
8 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ertical T ermination - Direct V ent ONL Y A vertical vent system must terminate no less than 8’ (2.
9 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • This unit does not require any opening for in- spection of vent pipe.
10 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
1 1 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fig. 10 T ermination clearances. V enting Requirements - Natural V ent Only FP567 NVBR/NVBC VENTING RUNS 11/12/97 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height.
12 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof.
13 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, V enting System Assembly . 1.
14 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting System Assembly - Direct V ent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly .
15 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the V ent Adapter Pipe (Simpson Dura-V ent Components) 1. Install the Restrictor Plate. Consult the ‘V ent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed.
16 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 For DuraV ent pipe only: Install vent pipe by align- ing the locking system together , sliding the pipes together and twisting clockwise. • Install 90° elbow . T wist lock as before. • Slide the wall plate over horizontal run before at - taching the horizontal run to the elbow .
17 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ent T ermination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level.
18 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints.
19 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Attach the first section of venting to the draft hood. De- pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
20 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFP A 54. Since some municipalities have additional local codes, be sure to consult your local authority .
21 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open.
22 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
23 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 45. Follow the lighting instructions on Page 25 exactly .
24 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
25 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 T roubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. W ARNING: REMOVE THE GLASS P ANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
26 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction.
27 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Pilot Orifice Conversion 1. Locate pilot. (Fig. 49) 2. Replace pilot orifice. Pilot T ype 1 • Remove pilot hood by lifting up. (Fig. 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver- sion.
28 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 21. Replace burner . Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base.
29 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Maintenance Y our Dutchwest Gas Heater will provide years of ser - vice with minimal upkeep.
30 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
31 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Wiring Diagrams OFF ON Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124b on/off/s witch wiring 1.
32 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 1a 1b 1c 2 10 12 1 1 PILOT ON OFF PILOT ADJ L O H I 23 27 28 32 CEMENT 34 35 1 3 4 6 7 5 8 13a,b 15a 17 19 14 18 20 21 15b 16a,b, c,d 25 2.
33 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Ref. Description Dutchwest Dutchwest Direct V ent / Natural V ent Gas Heater Models 2465, 2466 (continued) 10. Glass, DV25 1601691 1 1. Glass Frame Assembly - SDV30 30000127 12. Gasket, Glass - Med.
34 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture.
35 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 LIMITED LIFETIME W ARRANTY PRODUCT COVERED BY THIS W ARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner .
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .
Ein wichtiger Punkt beim Kauf des Geräts Vermont Casting 2466 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Casting 2466 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Casting 2466 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Casting 2466 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Casting 2466 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Casting 2466 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Casting 2466 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Casting 2466. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Casting 2466 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.