Benutzeranleitung / Produktwartung 36" Flame Oak Log des Produzenten Vanguard Heating
Zur Seite of 26
UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER V ariable Manually-Contr olled Models Also Design-Certified As V ented Decorative Appliances ® Save this manual for future reference. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
2 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea.
3 104309 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® PROVIDING ADEQUATE VENTILATION The following ar e excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 104309 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 104309 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear * Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21&quo.
8 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below.
9 104309 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf.
10 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel.
11 104309 OWNER’S MANUAL CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane sup- ply. This heater requires an exter- nal regulator (not supplied).
12 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ON POSITION OFF POSITION Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Checking Gas Joints WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
13 104309 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS It is very important to install the logs exactly as instructed.
14 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® 1. STOP! Read the safety inf ormation, column 1. 2. Make sur e manual shutoff valve is fully open.
15 104309 OWNER’S MANUAL Figure 20- Pilot Ignitor Electrode Pilot Burner 8. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release contr ol knob . • If control knob does not pop out when released, contact a qualif ied service person or gas supplier f or repairs.
16 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® IMPORT ANT: This remote control has been specially engineered to take an air temperature sample e v- ery 5.5 minutes in the A UTO mode. It will not respond immediately to the temperature setting being turned up or do wn.
17 104309 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
18 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight s.
19 104309 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
20 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SPECIFICA TIONS Golden Oak Golden Oak 18" Remote 24”,30”,and 36" Ready Remote Ready Btu (Variable) 16,000/30,000 20,000/39,000 Type Gas Propane Only Propane Only Ignition Piezo Piezo Pressure Manifold 8.
21 104309 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person.
22 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX™ GOLDEN OAK LOG MODELS VYD18PR, VYD24PR, VYD30PR, AND VYD36PR 4 13 13 14 22 13 8 18 7 .
23 104309 OWNER’S MANUAL P ARTS LIST VYD18PR, VYD24PR, VYD30PR, AND VYD36PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY PART NUMBER FOR NO.
24 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information.
25 104309 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Ein wichtiger Punkt beim Kauf des Geräts Vanguard Heating 36" Flame Oak Log (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vanguard Heating 36" Flame Oak Log noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vanguard Heating 36" Flame Oak Log - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vanguard Heating 36" Flame Oak Log reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vanguard Heating 36" Flame Oak Log erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vanguard Heating 36" Flame Oak Log besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vanguard Heating 36" Flame Oak Log verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vanguard Heating 36" Flame Oak Log. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vanguard Heating 36" Flame Oak Log gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.