M odel UT371/372 OPERA TI NG M ANUAL.
T ABLE OF CONTENTS TITLE P AGE 3 3 4 5 6 7 8 9 1 1 13 13 15 17 Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Setup Display Symbols Measurement Operation A.
T ABLE OF CONTENTS TITLE P AGE 18 18 19 20 20 20 21 21 22 Specifications A. General Specifications B. Environmental Requirements Accuracy Specifications A.
Model UT371 and UT372 is a stable, safe and reliable digital non-contact T achometer . This T achometer can measure RPM and counts. RPM range is 10 ~ 99999 while counts range is 0 ~ 99999.
In the event you find any missing or damage, please contact your dealer immediately . This Meter complies with the standards IEC61010-031, IEC61326, : in pollution degree 2 Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
Rules For Safe Operation Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Do not use or store the Meter in an environment of high temperature, humidity , explosive, inflammable and strong magnetic field.
Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. T urn the Meter off when it is not in use and take out the battery when not using for a long time.
Figure 1 The Meter Structure (see figure 1) T achometer Light Source. LCD Display . USB Port (UT372 only) Housing Functional Buttons Model UT371/372: OPERA TING MANUAL 7.
Functional Buttons Below table indicated for information about the functional button operations. Button Operation Performed l Press once to turn the meter on. l Press and hold for 1 minute to turn it off. l When measuring RPM and Counts, press once to enter the Hold mode.
Setup A. USB setup Press R/C button to select USB feature after turning on the Meter . Then press M/M/A button to setup 0 or 1. 0 means turn the USB off. 1 means enable the USB feature. B. LED setup Press R/C button to select LED feature after turning on the Meter .
if you do not press any button for 10 minutes. Y ou could press ON/OFF button to turn on the Meter again after the Meter is off. E. CLK setup Press R/C button to select CLK feature after turning on the Meter . Then press M/M/A button to setup 0 or 1. 0 is hours and minutes format.
Display Symbols (see figure 2) Figure 2 Model UT371/372: OPERA TING MANUAL 1 1.
1 2 3 4 5 6 7 8 9 10 1 1 12 Unit of T achometer Unit of Counts T ime The battery is low . Indicator of Sleep Mode Measurement of RPM and Counts Data Hold is on Display of Maximum reading Display of Mi.
W arning W arning T o reserve battery , the USB feature will be automatically off when the Meter is restarted. The other setting remains unchanged. The Time will be off after the HOLD feature is enabled. The time will be on again after existing HOLD mode.
Figure 3 T o carry out RPM measuremnet, follow the following procedure: Apply a piece of reflecting tape to the object under test. Position the Meter on a flat place. Hold the Meter 50~200mm from the T achometer light source to the object under test. Press ON/OFF button, the Meter is default to enter the RPM measurement mode.
Figure 4 B. Counts Self-lighted Counts (see figure 4) 1. Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30° from the T achometer light source to the object under test. 2. Press the ON/OFF button 3.
Receiving Light Source Outside (see figure 5) Figure 5 Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30° from the T achometer light source to the object under test.
Figure 6 C. Data T ransferring and USB (UT372 only , see figure 6) Connect the USB interface cable, the Meter and the computer as per the figure 6. Model UT371/372: OPERA TING MANUAL 17.
A. General Specifications l Display: 5 digits LCD display , Maximum display 99999. l Overloading: Display OL . l Battery Deficiency: Display . l Sampling Rate: 5 mini-second to 255 mini seconds adjustable. l T ransducer T yype: Photo Diode and Laser l Measurement Distance: 50mm ~ 200mm l Drop T est: one meter l Power: 4pcs x 1.
B. Environmental Requirements l For indoor use only . l Altitude: 2000m l T emperature and humidity: Ø Operating: 0 o C~30 o C( 85%R.H) 30 o C~40 o C ( 75%R.H) 40 o C~50 o C ( 45%R.H) Ø Storage: -20 o C~ +60 o C( 85%R.H) l Safety/ Compliances: IEC61010-031, IEC61326, IEC 61010-1 pollution degree 2.
Accurate Specifications Accuracy: (a% reading + b digits), guarantee for 1 year . Operating temperature: 23 o C 5 o C Operating humidity: 80%RH T emperature Coefficient: 0.1 x (accuracy) / o C Range Resolution Accuracy 10~99.999 r/min 100~999.99 r/min 1000~9999.
MAINTENANCE This section provides basic maintenance information including battery replacement instruction. W arning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information.
B. Replacing the Battery (see figure 7) Figure 7 1. Press ON/OFF to turn the Meter off. 2. T urn the Meter’s front case down. 3. Remove the screw from the battery door , and separate the battery door from the case bottom. 4. T ake out the old battery and replace with 4 x 1.
* END * This operating manual is subject to change without notice. Model UT371/372: OPERA TING MANUAL 23.
Copyright 2007 Uni-T rend Group Limited. All rights reserved. Manufacturer: Uni-T rend T echnology (Dongguan) Limited Dong Fang Da Dao Bei Shan Dong Fang Industrial Development District Hu Men T own, .
Ein wichtiger Punkt beim Kauf des Geräts Uni-T UT371 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Uni-T UT371 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Uni-T UT371 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Uni-T UT371 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Uni-T UT371 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Uni-T UT371 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Uni-T UT371 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Uni-T UT371. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Uni-T UT371 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.