Benutzeranleitung / Produktwartung VM700T des Produzenten Tektronix
Zur Seite of 16
VM700 T (turbo) V ideo Measurement Set Option 11 P AL V ideo Measurements M any capabilities in one instrument – Digitizing waveform monitor – Digitizing vectorscope – Picture Display – Group .
modem to report measurement r esults or control a signal router . A relative to reference mode allows normalizing to a signal source or eliminate signal path errors from the desired measurement.
Vertical interval test signals can be seen very clearly for additional analysis of the signal. These can be printed as support documentation for automatic measurement results. E ven a single horizontal synchronization pulse can be displayed at a high intensity .
Bar Line Time measurement. Chrominance to Luminance Gain and Delay measurement. MEASURE MODE 1,2 BAR LINE TIME A bsolute Relative M easurement Range Mode Mode Accuracy Accuracy B ar Level (b1 or Back Porch) 300 mV to 1.4 V ± 0.5% ± 0.2% S ync Level 50 mV to 600 mV ± 0.
Chrominance Non-Linearity measurement. Color Bar measurement. Luminance Level (mV ) Luminance Level (mV ) Chrominance Level (mV ) Chrominance Level (mV ) Chrominance Phase (deg) Chrominance Phase (deg) Gray Gray Yellow Yellow Cyan Cyan Green Green Magenta Magenta Red Red Blue Blue Black Black 0.
Frequency Response and Group Delay measurement using Sin X/X. Horizontal Timing measurement. M EASURE MODE (continued) FREQUENCY RESPONSE AND GROUP DELA Y A bsolute Relative M easurement Range Mode Mode A ccuracy Accuracy F requency Response to 5 MHz ± 40 dB ± 1.
LINE FREQUENCY M easurement Range Accuracy L ine Frequency ± 3% ± 0.1% F ield Frequency ± 3% ± 0.1% LUMINANCE NON-LINEARITY Absolute Relative M easurement Range Mode Mode A ccuracy Accuracy L uminance Non-Linearity 0 to 100% ± 0.4% ± 0.2% K-factor measurement.
VERTICAL BLANKING M easurement Range Absolute Mode Accuracy E qualizing Pulse Width 80 ns to 1 µs ± 10 ns B road Pulse Width 80 ns to 1 µs ± 10 ns V ertical Blanking Field 1 19 to 30 lines NA Vertical Blanking Field 2 19 to 30 lines NA Noise Spectrum measurement.
AMPLITUDE AND PHASE MEASUREMENTS (continued) M easurement Range Accuracy ITS Element Standard D ifferential Gain 0 to +100% ± 0.3% D2 CCIR Rec. 569 ( Peak and p-p) (0% nominal) D ifferential Phase 0 to 360 deg ± 0.
Unified Unweighted filter response curve per CCIR Recommendation 567. 0 –5 5 08 M Hz d BV –5 – 10 – 15 –2 0 –2 5 –3 0 –3 5 –4 0 – 45 –5 0 1 234 5 67 U nified Luminance weighted filter response curve per CCIR Recommendation 567. 0 – 14 05 MHz dBV .
Measur ement r esults are displayed in an easy-to-read format indicating the time, signal source, measurement, and whether the measured value exceeded caution (*) or alarm (**) limits.
Measurement methods The following paragraphs specify the methods for each Option 11 measurement. Where appropriate, reference is made to the relevant CCIR recommendation. Line blanking timing measurements Color Burst Duration: Measured between the half-amplitude points of the burst chrominance envelope.
Other timing measurements B ar Rise T ime: M easured between the 10% and 90% points on the leading edge of bar . See element B2. A mplitude and phase measurements Sync Amplitude Error: Measured as the difference b etween the sampled sync pulse amplitude and a nominal 300 mV amplitude.
C/L Gain Inequality: Measured as the difference between the sampled peak-to-peak ampli- tude of the 700 mV (nominal) chrominance packet (G1 or G2) and the sampled amplitude of the luminance bar (also nomi- nally 700 mV). Result expressed as a % of sampled bar amplitude.
Frequency response measurements M ultiburst Flag Amplitude: Measured from the center point of the flag top to the ensuing bottom of the flag. Result e xpressed as % of sampled bar a mplitude.
Contact T ektronix: A SEAN / Australasia / Pakistan ( 65) 6356 3900 A ustria + 41 52 675 3777 B alkan, Israel, South Africa and other ISE Countries + 41 52 675 3777 B elgium 0 7 81 60166 B razil &.
Ein wichtiger Punkt beim Kauf des Geräts Tektronix VM700T (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Tektronix VM700T noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Tektronix VM700T - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Tektronix VM700T reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Tektronix VM700T erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Tektronix VM700T besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Tektronix VM700T verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Tektronix VM700T. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Tektronix VM700T gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.