Benutzeranleitung / Produktwartung P8050 des Produzenten Stovax
Zur Seite of 20
Brunel Mk III Conventional Flue With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR0595 Issue 4 (August 2008) IMPOR T ANT Do not attempt to burn rubbish in this fire. This stove must only be operated with the door secured firmly in position.
2 CONTENTS COVERING THE FOLLOWING MODELS BRUNEL - 8050 - P8050 PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Technical Specifications 8 Site Requirements 9 In.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 2.3 • Holdin for 5to 10seconds and thenrelease The pilot remains lit. If the pilot does not light, repeat the procedure.
5 4.2 • Holdin the controlknob androtate anti-clockwise until the knob is pointing at the ignition symbol ( ★ ) • Applya lightedmatch tothe pilothood, Diagram 3 3 AR0897 4.
6 USER INSTRUCTIONS AR0900 6 6.4 • Placethree coals equallyspaced onthe rear ofthe fuel bed so they touch the rear panel, Diagram 7 AR0901 7 6.
7 USER INSTRUCTIONS 9. 'RUNNING IN' 9.1 The surface coating on your GAZCO stove will ‘burn off’ during the first 24 hours of operation on high, producing a harmless and temporary odour. If the odour persists ask your retail for advice. 10.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models Brunel - 8050 - P8050 Model Gas Cat. Gas Type Pressure Nox Class Aeration Injector Gas Rate m 3 / h Input kW (Gros) Country Hoog Laag Brunel 8050 I 2H Natural Gas (G20) 20mbar 5 4 x 16 120 0.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm (5”) in diameter. The following are suitable for use with this appliance.
10 2.3 Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. • Connectthe gassupply tothe 8mm-compressionelbow at the RH rear corner of the stove, Diagram 3.
11 AR0886 4 2.7 • Placethe closure plateagainst thefireplace opening • • Ensurethere is sufficientoverlap aroundthe perimeter to allow a fume tight seal to be made • Cutstraight acrossthe topof theplate if trimmingis required 2.
12 3.5 • Placefive coals onthe frontof the fuelbed sothey rest on the front coal effect and lean against the vertical fingers, Diagram 9 AR0902 9 3.
13 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING 1.1 • Closeall openable doorsand windowsin the room • Ignitethe stoveand operateon maximum for10 minutes AR0539 1 If there is any doubt, run the stove for a further 10 minutes, and repeat the test.
14 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see diagram 1 on page 17.
15 SERVICING INSTRUCTIONS FAULT FINDING CHARTS PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipework or fittings which lead to the fire.
16 3. IGNITION LEAD AND PIEZO Due to the method of manufacture, these components can only be replaced as an integral unit. 3.1 • Turnthe gas supplyoff atthe isolation d.
17 AR0320 3 • Prisethe smallretaining ringout ofthe inlet andremove the filter 4.2 • Replacewith a newfilter andpush into positionensuring that it sits on the shoulder • Replacethe retainingring andpush intoposition.
18 8. PRIMARY AERATION PLATE 8.1 • Turnthe gas supplyoff atthe isolation device. 8.2 To open the doors: • Slackenthe domednut onthe upperdoor and loosen the bolt from behind the latch 8.
19 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: ................................. Next Service due: ............................... N e x t S e r v i c e d u e : .
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Ein wichtiger Punkt beim Kauf des Geräts Stovax P8050 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Stovax P8050 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Stovax P8050 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Stovax P8050 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Stovax P8050 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Stovax P8050 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Stovax P8050 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Stovax P8050. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Stovax P8050 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.