Benutzeranleitung / Produktwartung 1000 des Produzenten SPX Cooling Technologies
Zur Seite of 12
/ Mar le y Sigma 1 0 0 0/120 0 Cooling T ower /.
2 Y ou’ll enjoy single source r esponsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system.
3 / Sigma Adv antag e / • GuaranteedPerformance. Don’t r ely on outside agencies with limited enforcement powers. W e’ll stand by our responsibility for r eliable thermal performance. We designed it. W e rate it. We guarantee it! • Exclusive5-Y earMechanicalW arranty .
4 / Constr uction and Components / Fill/Louvers/Drift Eliminators Marley high-performance film fill is the heart of every Sigma tower . A repeating chevr on pattern provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airflow so you’ll save on fan power .
5 fans, used on larger models, include hollow GRE (glass- reinfor ced epoxy) blades and epoxy-coated cast iron hubs. Blades on both fan types are adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual job site restrictions.
6 W ater Distribution System The gravity-flow water distribution system designed into the Sigma tower essentially reduces pump head to its most basic component – static lift – saving you money on pump power . Y ou won’t have to for ce water through internal piping and pressur e spray nozzles, as you would in a counterflow tower .
7 The 4" x" 4 tower diagonals carry loads to heavy- duty hot-dip galvanized steel anchor plates or hot-dip galvanized anchor weldments. The system of longitudinal and transverse diagonal bracing provides stability in a true tension-compression design.
8 / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Plywood Cold W ater Collection Basin Pressur e-treated Douglas fir plywood collection basin for towers located above grade. See page 11. Bottom-Outlet Sump Square-plan galvanized steel sump with bottom outlet.
9 Cell Partition Options Every Sigma tower includes plenum chamber partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions ensure consistent thermal performance as you shut off one fan at a time.
10 Fire Pr otection Options The PVC fill, louvers and drift eliminators used on Sigma towers are fir e-retar dant, having flame spread ratings less than 25 per ASTM E-84. Standard fan decking material is pressur e-treated fir plywood which ignites poorly and burns slowly .
11 Cold W ater Collection Basins If you plan to locate your tower above grade, a treated Douglas fir Marley cold water collection basin is available, complete with the necessary operating accessories. The basin floor is exterior grade, pressur e-treated fir plywood, supported on joists.
/ Additional Services / SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project.
Ein wichtiger Punkt beim Kauf des Geräts SPX Cooling Technologies 1000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie SPX Cooling Technologies 1000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für SPX Cooling Technologies 1000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von SPX Cooling Technologies 1000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über SPX Cooling Technologies 1000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon SPX Cooling Technologies 1000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von SPX Cooling Technologies 1000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit SPX Cooling Technologies 1000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei SPX Cooling Technologies 1000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.