Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 1 Model: QV36DC-A Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Owner ’ s Manual .
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 3 T ABLE OF CONTENTS Safety and W arning Information .................................................2 Service Parts Lists ....................................................................... 4 Section 1: Approvals and Codes .
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 7 1 Approvals and Codes Appliance Certi fi cation The fi replace model discussed in this Owner ’s Manual has been tested to certi fi cation standards and listed by the applicable laboratories.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 8 Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, buil.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 9 2 Getting Started Introducing Quadra-Fire Gas Fireplaces Quadra-Fire direct vent gas fi replaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 10 Figure 1. Diagram of the QV36DC-A TOP ST ANDOFFS HOOD ELECTRICAL ACCESS GAS CONTROLS RA TING PLA TE AND LABELS GAS LINE ACCESS 41 1/8 [1044mm].
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 11 3 Installing the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fi replace within a room. A B C D E 42” 22” 36” 51” 72” Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front .
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 12 Framing should be c o n s t r u c t e do f2X4 lumber or heavier . Shows center of 10” x 12” vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 13 Figure 4. DVP-Series Direct V ent Component Speci fi cations (5-inch inner pipe / 8-inch outer pipe) NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . DVP90ST 12-9/16 11 - 1 / 4 7-1/4 1-1/4 TYP 1/2 TYP 8-9/16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 14 Figure 5. V ent System Components and T ermination Kits Identifying V ent Components The vent systems installed on this gas fi replace may include one, two, or three 90° elbow assemblies.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 15 Figure 6. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 40’ MAX. (12.4 M) Flue Restrictor Instructions 1. Remove screws with a 1/4 nut driver . Adjust to desired position per table.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 16 HORIZONT AL VENTING Kit No. H Max. Run DVP-TRAP 24” (610 mm) Figure 10. Corner Installation NOTE: This model is tested and approved to use 45° elbows in corner installations. However , 90° elbows will result in better performance.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 17 V H 1’ MIN. (305mm) 2’ MAX. (610mm) 2’ MIN. (610mm) 4’ MAX. (1.22m) 3’ MIN. (914mm) 6’ MAX.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 18 Figure 13. V enting with T wo 90° Elbows VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 19 Figure 15. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 20 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H (FT .) 1’ MIN. (305mm) 5’ MAX. (1.52m) 2’ MIN. (610mm) 10’ MAX. (3.1m) 3’ MIN. (914mm) 15’ MAX. (4.65m) 4’ MIN. (1.22m) 20’ MAX. (6.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 21 V enting Out the T op V ent Remove the two screws in the top vent collar seal cap and remove the top vent collar seal cap and the two pieces of insulation inside the top two starting collars (See Figure 17).
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 22 Figure 19. HEA T SHIELD 3” MIN. (76 mm) COMBUSTIBLE SURF ACE T o Install the Heat Shield: 1. Determine if the heat shield is required. Do so by mea- suring the vertical distance between the top horizontal surface of the elbow to any combustible surface above.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 23 5. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior fi restop on an exterior combustible wall.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 24 For V ertical Runs - One ceiling fi restop is REQUIRED at the hole in each ceiling through which the vent passes. T o install fi restops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 25 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 26 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 27 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fi replace into position. • Level the fi replace from side to side and from front to back. • Shim the fi replace with non-combustible material, such as sheet metal, as necessary .
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 28 • Insert insulation from the outside of the fi replace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 29 Optional Accessories Optional fan and remote control kits require that 1 10-120 V AC be wired to the factory installed junction box before the fi replace is permanently installed. W all Switch Position the wall switch in the desired position on a wall.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 30 Step 9. Finishing Figure 36 shows the minimum vertical and corresponding maximum horizontal dimensions of fi replace mantels or other combustible projections above the top front edge of the fi replace.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 31 Figure 38. Figure 39. Figure 40. Figure 39. Figure 42. Position the right wall all the way to back wall.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 32 Placing the Ember Material • Release the four glass latches on the glass frame. Re- move glass door from the unit. • Glowing Ember material can be placed without remov- ing logs. Place a single layer of dime size and thickness pieces on exposed area of burner front and burner center .
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 33 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 34 After the Installation LEA VE THIS INST ALLA TION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 35 A. Standing Pilot Ignition System Symptom Possible Causes Corrective Action 1. After repeated triggering of the red or black piezo ignitor button, the spark ignitor will not light the pilot. a.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 36 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 37 Limited Lifetime W arranty Î.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 38 Limited Lifetime W arranty Î.
Quadra-Fire • QV36DC-A • 2161-900 Rev . C • 6/09 39 Contact Information - NOTES - ________________________________________________________________________________ _______________________________.
Ein wichtiger Punkt beim Kauf des Geräts Quadra-Fire QV36DC-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Quadra-Fire QV36DC-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Quadra-Fire QV36DC-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Quadra-Fire QV36DC-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Quadra-Fire QV36DC-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Quadra-Fire QV36DC-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Quadra-Fire QV36DC-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Quadra-Fire QV36DC-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Quadra-Fire QV36DC-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.