Benutzeranleitung / Produktwartung VS5008 des Produzenten Pelco
Zur Seite of 20
® VS5004/VS5008 Sequential Switcher INSTALLATION/OPERATION C808M-G (4/05).
2 C808M-G (4/05) Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Models .
C808M-G (4/05) 3 Description The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron ® compatible and can be placed on a desktop or rack mounted.
4 C808M-G (4/05) Installation T ERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008). VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output.
C808M-G (4/05) 5 Figure 2. VS5008 T erminated Camera Inputs - One Monitor Figure 3. VS5004 Alarm Connections VS5008 (REAR) MON 1 MON 2 MON X CAMERAS 87654321 12 V AC INPUT ALARM INPUT COM ALARM OUT 12345678 NOTE: MON 1 MUST BE TERMINA TED.
6 C808M-G (4/05) Figure 4. VS5008 Alarm Connections 12 V AC INPUT ALARM INPUT COM ALARM OUT 12345678 MON 1 MON 2 MON X CAMERAS 87654321 UP TO EIGHT ALARM INPUTS (ALARM INPUT FROM MOTION DETECTOR, DOOR CONT ACT , ETC., THROUGH NORMALL Y OPEN SWITCH). EACH ALARM DEVICE MUST BE CONNECTED TO THE "COM" TERMINAL.
C808M-G (4/05) 7 LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Convert the switcher to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a. Remove the cover . b. Remove the rear panel of the chassis.
8 C808M-G (4/05) Figure 5. Looping Conversion Modification Figure 6. VS5004 Looping Camera Inputs - One Monitor 75-OHM RESISTOR REAR PANEL (SWITCHER) BNC CONNECTOR CLIP HERE FOR EACH CHANNEL MON 1 MO.
C808M-G (4/05) 9 Figure 7. VS5008 Looping Camera Inputs - One Monitor T ERMINATED CAMERA INPUTS AND T WO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis.
10 C808M-G (4/05) 4. Set the ALARM switch to the ON position. NOTES: • With all channel switches set to the AUTO position, both monitors immediately switch to the alarmed channel and the associated LED blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008).
C808M-G (4/05) 11 Figure 9. VS5004 T erminated Camera Inputs - T wo Monitors Figure 10. VS5008 T erminated Camera Inputs - T wo Monitors MON 2 MON 1 MON 2 43 2 1 ALARM 12 V AC INPUT IN 1 2 3 4 OUT 6 C.
12 C808M-G (4/05) LOOPING CAMERA INPUTS AND T WO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis.
C808M-G (4/05) 13 7. Connect the AC adapter to the 12 V AC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 V AC (VS5004 or VS5008) or 230 V AC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing.
14 C808M-G (4/05) COAXITRON CONTROL To convert for use with a Coaxitron transmitter , do the following: 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis.
C808M-G (4/05) 15 6. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switch set to the BYP ASS position.
16 C808M-G (4/05) Figure 13. VS5004 with Coaxitron Control Figure 14. VS5008 with Coaxitron Control COAXITRON® RECEIVER MON 1 MON 1 MON 2 43 2 1 ALARM 12 V AC INPUT IN 1 2 3 4 OUT 6 COMMON 5 LOOPING .
C808M-G (4/05) 17 Specifications VIDEO Inputs T erminating (75 ohms) or looping Outputs Monitor 1 75 ohms Monitor 2 VS5004 Hi Z VS5008 75 ohms Monitor X VS5008 Coaxitron transmitter (nonamplified) o.
18 C808M-G (4/05).
PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Ein wichtiger Punkt beim Kauf des Geräts Pelco VS5008 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco VS5008 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco VS5008 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco VS5008 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco VS5008 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco VS5008 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco VS5008 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco VS5008. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco VS5008 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.