Benutzeranleitung / Produktwartung FR85081 des Produzenten Pelco
Zur Seite of 33
® Pelco World Headquarters • 3500 Pelco Way, Clovis, California 93612-5699 USA USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150 International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120 www.
® INST ALLA TION FT85081/FR85081 Fiber T ransmitter and Receiver Eight-Channel Digitally Encoded V ideo with Bidirectional Data C1648M (4/05).
2 C1648M (4/05) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C1648M (4/05) 3 List of T ables A Data Selection Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 B Data Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C1648M (4/05) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
C1648M (4/05) 5 CAUTION: These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualifi ed to do so.
6 C1648M (4/05) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C1648M (4/05) 7 Product Overview DESCRIPTION The FT85081/FR85081 fiber transmitter and receiver provide the ability to transmit eight unidirectional composite video channels and one bidirectional data channel over one optical fiber (refer to Figure 1).
8 C1648M (4/05) MODELS The FT85081/FR85081 fiber transmitter and receiver consist of the following series of models: Multimode Models: FT85081MSTR Eight-channel fiber optic video transmitter/single-.
C1648M (4/05) 9 FRONT PANEL The front panel of the FT85081 transmitter and the FR85081 receiver provides LED indicators that allow you to monitor data activity, signal status, and operating power. The following sections provide a view of the front panel of the FT85081 transmitter and the FR85081 receiver .
10 C1648M (4/05) FRONT PANEL - FR85081 RECEIVER Figure 3 illustrates the front panel of the FR85081 receiver. Figure 3. Front Panel of FR85081 Receiver DA TA TX LED DA TA RX LED POWER LED .
C1648M (4/05) 11 REAR PANEL Connections to the FT85081 transmitter and the FR85081 receiver are made to the rear panel of the module. The following sections provide a view of the rear panel of the FT85081 transmitter and the FR85081 receiver. REAR PANEL - FT85081 T RANSMITTER Figure 4 illustrates the rear panel of the FT85081 transmitter.
12 C1648M (4/05) REAR PANEL - FR85081 RECEIVER Figure 5 illustrates the rear panel of the FR85081 receiver. Figure 5. Rear Panel of FR85081 Receiver RACK POWER/ALARM CONNECTOR, 4-pin connector for.
C1648M (4/05) 13 Installation PACKAGE CONTENTS The following items are supplied: • With the FT85081 transmitter: 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 V AC input, 12 VDC output 1W all clip with two 4-40 x .
14 C1648M (4/05) With the FT85081 transmitter/FR85081 receiver powered off, turn the Data Selection switch using a screwdriver until the number representing the required data communication is selected. Refer to T able A for Data Selection switch settings.
C1648M (4/05) 15 • RK5000PS-5U: Designed to accommodate Endur a ™ modules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5003-1UEXP adapter kit is required for installation of the FT85081 transmitter/ FR85081 receiver into the RK5000PS-5U chassis.
16 C1648M (4/05) CONNECTIONS Connections to the FT85081 transmitter and the FR85081 receiver are made on the rear panel of the modules and consist of the following: • Power connection NOTE: A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a standalone module.
C1648M (4/05) 17 T able B. Data Connector Pin Assignments Pin Number RS-232 RS-422 RS-485 2-Wire RS-485 4-Wire Manchester Bi-Phase 1— Out+ In+/Out+ Out+ — — 2— Out- In-/Out- Out- — — 3— .
18 C1648M (4/05) Figure 9. RS-232 Data Communication Wiring RS-232 DATA SELECTION RS-232 DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER FR85081 RECEIVER – DATA CONNECTOR 1 2 3 4 5 (RX) DATA .
C1648M (4/05) 19 Figure 10. RS-422 Data Communication Wiring RS-422 DATA SELECTION RS-422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER 1 (TX+) DATA OUT+ 2 (TX-) DATA OUT- 3 (RX+) DATA IN+ 4 .
20 C1648M (4/05) Figure 11. RS-485 2-Wire (Half Duplex) Data Communication Wiring RS-485 2-WIRE DATA SELECTION FR85081 RECEIVER – DATA CONNECTOR 3 4 5 6 7 8 GND RX+/TX+ -- RX /TX DEVICE A FT85081 TR.
C1648M (4/05) 21 Figure 12. RS-485 4-Wire (Full Duplex) Data Communication Wiring RS-485 4-WIRE DATA SELECTION RS-485 4-WIRE FR85081 DATA CONNECTIONS BETWEEN DEVICE A AND RECEIVER FR85081 RECEIVER –.
22 C1648M (4/05) Figure 13. Manchester Data Communication Wiring MANCHESTER MANCHESTER DATA SELECTION MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER FR85081 RECEIVER – DATA CONNEC.
C1648M (4/05) 23 Figure 14. Bi-Phase Data Communication Wiring BI-PHASE DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER BI-PHASE DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER FT8508.
24 C1648M (4/05) T roubleshooting LED indicators on the front panel of the FT85081 transmitter/FR85081 receiver (refer to Figure 2 and Figure 3, respectively) allow you to monitor signal status, data activity , and operating power . T able C provides information about the front-panel indicators and associated troubleshooting guidelines.
C1648M (4/05) 25 Video Present LED (Continued) Red on receiver Incoming video signal is not present on the channel. Optical signal is not being received from the transmitter . Carrier Detect LED is also red. Refer to the Carrier Detect LED troubleshooting section below .
26 C1648M (4/05) Carrier Detect LED (Continued) Red on transmitter (continued) A problem exists with the optical power budget. V erify that losses in fiber optic cable do not exceed the optical power budget specification of the fiber optic link. If the losses do exceed the optical power budget, contact Product Support.
C1648M (4/05) 27 Data Tx LED Flashing amber Data is being transmitted onto the fiber by the data port. — No action required. Red Data Selection switch is set to an invalid setting. Data Selection switch is set to setting 5, 6, 7, 8, or 9. Set Data Selection switch to the correct setting for the desired data communication (refer to T able A).
28 C1648M (4/05) Specifications VIDEO Number of Channels 8 Modulation T ype Pulse code modulation, 8-bit resolution Video Input 1.0 Vp-p, 75 ohms; NTSC, PAL, and SECAM Bandwidth 6.5 MHz Gain Unity Crosstalk -50 dB typical at 3.58 MHz Differential Gain <1% Differential Phase <1.
C1648M (4/05) 29 OPTICAL POWER BUDGET , TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT Fiber Wavelength Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* Multimode (62.5/125 µm) 1310 nm (video) 20 dB † 1 km (0.6 mi) †† <15.
.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
Ein wichtiger Punkt beim Kauf des Geräts Pelco FR85081 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco FR85081 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco FR85081 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco FR85081 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco FR85081 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco FR85081 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco FR85081 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco FR85081. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco FR85081 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.