® INST ALLA TION EH3508/EH3512/EH3515 Series Environmental Enclosure C478M-M (1/06).
.
C478M-M (1/06) 3 Important Safety Instructions Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Only use attachments/accessories specifi ed by the manufacturer.
4 C478M-M (1/06) Description The EH3508/EH3512/EH3515 Series are indoor/outdoor light-duty camera enclosures designed for use with various cameras on the market and accommodate fi xed focal length or motorized zoom lenses, with or without auto-iris operation.
C478M-M (1/06) 5 Installation The following items are supplied to mount the enclosure: 2 1/4-20 x 0.500-inch hex head screws 2 Flat washers 2 Split washers The following items are supplied to mount the camera: 2 1/4-20 x 0.375-inch Phillips screws Figure 1.
6 C478M-M (1/06) Figure 2. Exploded View of EH3500 Series Assembly FLAT WASHER SPLIT WASHER HEX HEAD SCREW EM1450 WALL MOUNT (NOT SUPPLIED) GLANDS PHILLIPS SCREWS CAMERA SLED SLED MOUNTING SCREWS.
C478M-M (1/06) 7 Perform the following steps to install the enclosure, camera, and lens: 1. Unlatch and open the lid. 2. Remove the camera sled from the rail of the enclosure. a. Loosen the screws that hold the camera sled in place. b. Slide the sled forward so it can be lifted out over the screws.
8 C478M-M (1/06) 9. If the enclosure has accessories that require power, you will need to access the PC board. T o remove the cover, insert a screwdriver into the slot on top of the cover and lift the cover off.
C478M-M (1/06) 9 Figure 4. EH3508-1/-2/-3 Wiring Diagram 1 2 3 4 5 6 7 8 9 10 HEA TER DEFROSTER INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 24/120/230 V AC MODELS.
10 C478M-M (1/06) Figure 5. EH3512 Series Wiring Diagram NOTE: Blower applies to -1/-2/-3 models only. 1 2 3 4 5 6 7 8 9 10 HEA TER DIODE BRIDGE INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 24 V AC MODEL .
C478M-M (1/06) 11 Figure 6. EH3515 Series Wiring Diagram NOTE: Blower applies to -1/-2/-3 models only. 1 2 3 4 5 6 7 8 9 10 INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 120 V AC MODEL DEFROSTER BLOWER REA.
12 C478M-M (1/06) T able A. Enclosure Accessory Wiring Distances The following cable sizs are the minimum recommended for sue with the heater and defroster combination in enclosures in the EH3508 Series, and the heater, defroster , and blower combination in enclosures in the EH3512 Series and Eh3515 Series only .
C478M-M (1/06) 13 T able A. Enclosure Accessory Wiring Distances (Continued) Model Number Input V oltage Accessories Max. Power Consumption Cable Size Cable Distance EH3515-3 230 VAC at 50 Hz Heater D.
14 C478M-M (1/06) Example: An enclosure that requires 30 VA and is installed 94 feet (28 m) from the transformer would require a minimum wire gauge of 20 A WG.
C478M-M (1/06) 15 Operation If your enclosure has a thermostatically controlled heater, the thermostat is set to turn on at 50°F (10°C) and to turn off at 80°F (27°C).
16 C478M-M (1/06) Specifications Camera Mounting Multiple holes on adjustable camera sled; camera sled mounts in threaded strip for easier removal and can be inverted for additional camera elevation Camera and Lens Size Accommodates camera and lens combinations (including BNC connector) up to 2.
C478M-M (1/06) 17 Figure 7. EH3508, EH3512, EH3515 Dimension Drawing 5.14 (13.05) 3.88 (9.86) 2.00 (5.08) A B C EH3512 EH3515 A 14.75 (37.47) 17.75 (45.09) B 12.75 (32.38) 15.75 (40.00) C 1 1.25 (28.57) 14.25 (36.20) EH3508 10.75 (27.30) 8.75 (22.22) 7.
18 C478M-M (1/06) REVISION HISTORY Manual # Date Comments C478M-J 6/99 Moved the EH3508 Series enclosures from manual C1435M-A. Updated the description, installation instructions, and specifications. Updated wiring diagrams and dimension drawing. Modified per ECO 99-4749, which changed heater and defroster design.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
® Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
Ein wichtiger Punkt beim Kauf des Geräts Pelco EH3512 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco EH3512 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco EH3512 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco EH3512 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco EH3512 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco EH3512 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco EH3512 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco EH3512. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco EH3512 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.