INST ALLA TION C3425M-D (8/08) IS90 Series Camclosure ® Indoor Integrated Camera System.
2 C3425M-D (8/08) Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . .
C3425M-D (8/08) 3 List of Illustrations 1 Package Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Removing the Bubble . . . . . . . . . . . . . . . . . . . . . .
4 C3425M-D (8/08) Regulatory Notices This device complies with Part 15 of the FCC Rules. O peration is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C3425M-D (8/08) 5 Description The IS90 Series Camclosure ® integrated camera system combines a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/wall.
6 C3425M-D (8/08) Indoor dome, surface/flush mount, smoked and clear bubble, black finish PARTS LIST Camera T ype Lens/Iris NTSC P AL Color , Wide Dynamic Range, Day/Night 3-9.5 mm, Day/Night V arifocal, Auto Iris IS90B-DWV9 9-22 mm, Day/Night V arifocal, Auto Iris IS90B-DWV22 Color , High Resolution, Day/ Night 3-9.
C3425M-D (8/08) 7 Figure 1. Package Comp onents IS90 SERIES CAMCLOSURE WITH SMOKED BUBBLE LINER ADAPTER PLA TE CLEAR BUBBLE SHOWN ACTUAL SIZE SHIPPING BOX 8-32 X 1.00-INCH PHILLIPS P AN HEAD SCREWS (2) 8-32 X 0.75-INCH PHILLIPS P AN HEAD SELF-T APPING SCREWS (2) 8-32 X 2.
8 C3425M-D (8/08) Remove the Bubble T urn the bubble counterclockwise and lift (refer to Figure 2). Place th e bubble on a nonabrasive surface. If the liner is already installed, remo ve it b efore installing the unit. T o remove the liner , gently lift it from the unit.
C3425M-D (8/08) 9 Installation Y ou can install the IS90 Series Camclosure integrated camera system into any of the following: • Mount to the surface of a ceiling/wall (refer to Surface Installation: Ceiling/Wall on pa ge 9). • Install in a suspended ceiling (refer to In-Ceiling Installation: Suspended Ceiling o n page 11).
10 C3425M-D (8/08) Figure 3. Ceiling/Wall Installation Figure 4. Concrete Ceilin g/Wall Installation BACK BOX AND SURFACE MOUNT RING WAL L OR CEILING 6-32 TOGGLE BOL TS (NOT SUPPLIED) BACK BOX AND SUR.
C3425M-D (8/08) 11 IN-CEILING INSTALLATION: SUSPENDED CEILING 1. Remove the surfa ce mount ring from the back box (re fer to Figure 5): a. Place fingers on the circular marks located on the sides of the surface mount ring . b. Pinch the sides. c. Lift and remove the surface mount ring from the back box.
12 C3425M-D (8/08) 2. Pull video and power wires to the selected ceiling tile. 3. Mount the unit to the ceiling tile (refer to Figure 6 and Figure 7): a. Remove the ceiling tile from the ceiling. b. Cut a hole 4 inches (10 cm) in diameter in the ceiling tile.
C3425M-D (8/08) 13 4. Remove an adjacent ceiling tile to access the unit. 5. Connect the video cable/wires: • BNC: Connect the BNC connector from the unit to a mating BNC connector . • UTP: Blue wire = Video + Gray wire = Video - 6. Connect the power wires.
14 C3425M-D (8/08) 6. Attach the back box to the mounting surface: • If you have access behind the ceiling/wall (refer to Figure 6 on page 12): (1) Place the adapter plate on t he inside of the ceiling/wall. (2) Attach the back box to the ceiling/wall.
C3425M-D (8/08) 15 5. Attach the surface mount ring and b ack box to th e adapter plate with two supplied 8-32 x 2.50-inch Phillips pan head self-tapping screws. Figure 9. 4S Standard Electrical Bo x Instal lati on IN-CEILING INSTALLATION: 4S DEEP ELECTRICAL BOX 1.
16 C3425M-D (8/08) 5. Connect the power wires. AC operation only: If you are wiring more than one Camclosure to the same transforme r , connect one side of the transformer to the red wire on all uni ts; connect the other side of the transformer to the black wire on all units.
C3425M-D (8/08) 17 Camera Adjustments T o perform the following camera adjustments, connect a monitor . Then turn on power to the camera and monitor . T o use the service connector , refer to Service Connector on page 28.
18 C3425M-D (8/08) DN/CH/C SERIES ADJUSTMENTS Refer to Figure 12 to adjust the IS90-DN, IS90-CH, or IS90-C model. Figure 12. Adjusting the IS90-DN/C H/C Series Camclosure SWITCH SETTINGS Locate the DIP switch. Then set the switches for your installation.
C3425M-D (8/08) 19 SW4-4: Flickerless In certain lighting conditions, a flicker in the light source may affect camera operation. Flic kering can be caused by a number of conditions, including the qua lity of the source power and the age and type of fluorescent bulbs and ballasts.
20 C3425M-D (8/08) V ERTICAL PHASE ADJUSTMENT NOTE: Use this procedure for 24 V AC operation only . When using more than one camera power supply, a brief vertical roll may occur on the monitor when switching from one came ra to another . T o eliminate vert ical roll, reverse the 24 V AC connec tions on one camera.
C3425M-D (8/08) 21 DAY/NIGHT OPERATION NOTE: This section only applies to DN model cameras. DN model cameras regularly check the brightness level of the field of view t o determine when to switch between day (color) and nig ht (black-white) operation.
22 C3425M-D (8/08) DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS Refer to Figure 14 to adjust the IS90-DW or IS90-CW model. Figure 14. Adjusting the IS90-DW/ CW Series Camclosure SWITCH SETTINGS Locate the DIP switch. Then set the switches for your installation.
C3425M-D (8/08) 23 SW1-4: A WB (Auto White Balan ce)/MWB (Manual White Balance ) Auto white balance is enabled by default (O N). T o manually set and lock the white balance: 1. Set SW1-4 to ON. 2. Hold a white background in front of the lens until the video shows all white.
24 C3425M-D (8/08) SW1-8: Day/Night Operation (DW models only) NOTE: On CW models, SW1-8 is unused and does not affect camera operation . DW model cameras regularly check the brightness level of the field of view to determine when to switch between day (color) and nig ht (black-white) operation.
C3425M-D (8/08) 25 AUTO IRIS LEVEL ADJUSTMENT The electronics of the IS90-DW and IS90-CW Series Ca mclosures automatically adjust the camera to the auto iris. Auto iris level adjustments are not necessary . V ERTICAL PHASE ADJUSTMENT NOTE: Use this procedure for 24 V AC operation only .
26 C3425M-D (8/08) Camera Positioning Rotate and tilt the camera module to position the camera. NOTE: Do not over -rotate the module. Excessively turni ng the module in one direction could result in damage to the wiring.
C3425M-D (8/08) 27 Install Liner and Bubble 1. T o install the liner with a clear bubble (refer to Figure 17): a. Align the studs located on the camera module with the clips on the liner . b. Lightly pinch the sides of the liner , o pposite fro m the clips, and place the clips over the studs.
28 C3425M-D (8/08) Service Connector The IS90 Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it at the installation site to set up the field of view and focus the camera. Figure 1 9. Service Connector Pelco offers two optional items that plug directly in to the service connector .
C3425M-D (8/08) 29 T o assemble the cable: 1. Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directio ns supplied with the mini ature coaxial connector . 2. Attach the 2.5 mm monaural plug to the other end of the coaxial cable (refer to Figure 20): a.
30 C3425M-D (8/08) Specifications GENERAL Pan/T ilt Adjustment Manual Pan 360° T ilt 140° (20° to 160° range) Rotation 360° Construction Back Box and Surface Mount Ring ABS plastic Bubble Polycarbonate Finish White or black Environment Indoor Operating T emperature 32° to 120°F (0° to 49°C) Unit Weight 0.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, an y merc handise proved defective in materi al or workmanship for a period of one year after the date o f shipment.
Worl dwide He adquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Ein wichtiger Punkt beim Kauf des Geräts Pelco C3425M-D (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco C3425M-D noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco C3425M-D - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco C3425M-D reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco C3425M-D erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco C3425M-D besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco C3425M-D verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco C3425M-D. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco C3425M-D gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.