INST ALLA TION TW3001AR Active Receiver Single Channel for UTP T ransmission C1666M-A (4/06).
.
C1666M-A (4/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
4 C1666M-A (4/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C1666M-A (4/06) 5 Description The TW3001AR is a single-channel active receiver that can receive live video over unshielded twisted pair (UTP) cable. The adaptive technology in the TW3001AR automatically adjusts the low , medium and high frequency components of the video signal allowing for the best possible video transmission.
6 C1666M-A (4/06) PARTS OF THE RECEIVER Figure 1. TW3001AR Parts Rubber Feet (4): For placing unit on a fl at surface, such as a desk or shelf. Status LED: Lights red when there is no UTP video being received. Lights green when there is UTP video being received.
C1666M-A (4/06) 7 Installation Make sure all parts are present for the unit. 1 Universal power supply (Part #PS04-1502-0512G) 1 Wall clip 1 2-pin power connector 1 2-pin UTP connector MOUNTING The TW3001AR receiver is 3 rack units high and can be mounted into a fi ber rack, onto a wall using a fiber wall mount kit or into the supplied wall clip.
8 C1666M-A (4/06) USING A WALL CLIP To attach the TW3001AR receiver to a wall using the supplied wall clip, refer to Figure 2 and do the following: 1. Attach the wall clip to a wall using two screws (not supplied).
C1666M-A (4/06) 9 SETTING THE DIP SWITCHES Y ou can override the adaptive technology by manually adjusting switches 1-4 on the DIP Switch. The factory default switch positions are shown in Figure 3. Switches 1-4 are set to AUTO and Switch 5 is set to High Mode.
10 C1666M-A (4/06) APPLICATIONS Y ou can connect the TW3001AR active receiver to transmitters, such as the TW3001P passive trans- ceiver and the TW3001A T active transmitter , and to Pelco UTP cameras, such as the CC3710/CC3610 Series.
C1666M-A (4/06) 11 Figure 4 shows a TW3001AR connected to a UTP camclosure. Figure 4. TW3001AR Connected to a UTP Camclosure + - CAMCLOSURE TW3001AR UTP MONITOR 12 VDC OR 24 VAC POWER SUPPLY BLUE WIRE.
12 C1666M-A (4/06) Figure 5 shows a TW3001AR connected to a UTP fi xed camera. Figure 5. TW3001AR Connected to a UTP Fixed Camera + - TW3001AR FIXED CAMERA 8 PINS (4-/5+) MONITOR UTP PIN 5 + PIN 4 - .
C1666M-A (4/06) 13 Figure 6 shows a TW3001AR connected to a UTP Spectra dome for Coaxitron PTZ control. Figure 6. TW3001AR Connected to a Spectra Dome + - TW3001AR UTP VIDEO COAXITRON SPECTRA MONITOR .
14 C1666M-A (4/06) Figure 7 shows a TW3001AR connected to a TW3001P passive transceiver . The TW3001P then connects to a non-UTP fi xed camera. Figure 7.
C1666M-A (4/06) 15 Figure 8 shows a TW3001AR connected to a TW3032P passive transceiver . Figure 8. TW3001AR Connected to a 32-Channel Passive T ransceiver + - TW3001AR TW3032P MONITOR UTP 12 VDC OR 2.
16 C1666M-A (4/06) Figure 9 shows a TW3001AR connected to a TW3004P passive transceiver . The TW3004P then connects to a non-UTP fi xed camera. Figure 9.
C1666M-A (4/06) 17 Specifications ELECTRICAL Input Voltage 12 VDC or 24 VAC, 50-60Hz Power Consumption 2.5 watts Wire T ype Unshielded T wisted Pair (24 AWG maximum) Wire Category Cat3 or better DC L.
18 C1666M-A (4/06).
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
Ein wichtiger Punkt beim Kauf des Geräts Pelco C1666M-A (4/06) 3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco C1666M-A (4/06) 3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco C1666M-A (4/06) 3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco C1666M-A (4/06) 3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco C1666M-A (4/06) 3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco C1666M-A (4/06) 3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco C1666M-A (4/06) 3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco C1666M-A (4/06) 3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco C1666M-A (4/06) 3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.