BSX8-A2-GZ40-10 March 2005 1 BSX8000-5 Br oadband Services Switch Installation Instructions Document Number BSX8-A2-GZ40-10 March 2005 Contents Softwar e and Firmware License Ag reement ................ ................. ................ ..... 1 Product Documentat ion Online .
2 March 2005 BSX8-A2-GZ40-10 Software, including any cop y of either . If you hav e ex ecuted a separate written agreement cov er ing the Software supplied to you under this purchase, such separate written agreement shall gov ern.
BSX8-A2-GZ40-10 March 2005 3 BSX8000-5 Over view The BSX8000-5 Broadband Services Switch provides multi-gig abit Ethernet uplink suppor t capability , full-nonblocking s witching throughp ut, and enhanced management fu nctionality f or the 4000E and 12000E Broadband Loop Carriers (BLCs).
4 March 2005 BSX8-A2-GZ40-10 Unpacking and Inspecting the Equipment HANDLING PRECA UTIONS FOR ST A TIC-SENSITIVE DEVICES This pr oduct is designed to pr otect sensitive components fr om damage due to electr ostatic discharge (ESD) during normal ope ration.
BSX8-A2-GZ40-10 March 2005 5 Installing the BSX8000-5 in a BLC The 12000E is a 14-slot Broa dband Loop Carrier (BLC). Slots 1–1 2 are reserved f or access modules (such as the AIM240 00-48) and slo ts U1 and U2 ar e reserved f or uplink modules .
6 March 2005 BSX8-A2-GZ40-10 MIM-4000F The MIM-4000F is a f our-por t fiber gigabit Ethernet interf ace connecting directly to the gigabit Ether net s w itch in the BSX8000-5 uplink module. MIM-2E1 Plug y our E1 ca ble into one of the RJ45 E1 po r ts on the MIM-2E1 f aceplate.
BSX8-A2-GZ40-10 March 2005 7 Conf iguring Y our Windo ws PC to Communicate with NMS T o communicate with NMS, your PC’ s Ethernet interf ace must be on the same subnet as the BSX8000 -5. F or example , to configure the IP address unde r Windows XP: Procedur e 1.
8 March 2005 BSX8-A2-GZ40-10 The NMS home p age appears ..
BSX8-A2-GZ40-10 March 2005 9 NMS Management Conf iguration Use the Management Configuration scr een to set the u nit’ s IP address and other management par ameters. Procedur e T o configure manag ement par ameters: 1. F rom the home screen, click on t he Management Co nfig b utton.
10 March 2005 BSX8-A2-GZ40-10 3. Click on Submit. Command Line Interface (CLI) CLI System Requirements Straight-Thr ough RJ45 to RJ45 Etherne t Cable – Required f or estab lishing a direct co nnection from the COM port to a DB9 adapte r .
BSX8-A2-GZ40-10 March 2005 11 Connecting a PC Directly T o connect a PC directly to the DSLAM to use the CLI: Procedur e 1. Plug a DB9 to RJ45 adapter into the RS232 serial por t on your PC .
12 March 2005 BSX8-A2-GZ40-10 CLEAR_NVRAM If no interf ace modules are present in th e chassis, clears Non-V olatile Random Access Memory , restoring the DSLAM to factory defaults. DISABLE_TELNET Disables access to the DSLAM using T elnet. DISABLE_TFTP Disables access to the DS LAM using T rivial File T ransfer Protocol.
BSX8-A2-GZ40-10 March 2005 13 LED Indicators T able 2. LED States and Mea nings LED State Indication Additional Information PWR (Po wer) Solid green BSX8000-5 uplink mo dule is receiving power Both BLC power terminals are connected. Solid amber BSX8000-5 uplink mo dule is receiving power Only one of the BLC power terminals is connected.
14 March 2005 BSX8-A2-GZ40-10 10/100/1000BaseT Connectors The uplink ports are 8-pin unk ey ed modular jac ks f or a 10/10 0/1000BaseT interf ace. The MGMT port is an 8-pin modular jac k supporting 10/100BaseT .
BSX8-A2-GZ40-10 March 2005 15 Regulatory Compliance f or Class A Equipment The f ollowing regulatory compliance inf o rmation applies to a BSX8000-5 as installed in a P aradyne BLC .
16 March 2005 BSX8-A2-GZ40-10 *BSX8-A2-GZ40-10* *BSX8-A2-GZ40-10*.
Ein wichtiger Punkt beim Kauf des Geräts Paradyne BSX8000-5 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Paradyne BSX8000-5 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Paradyne BSX8000-5 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Paradyne BSX8000-5 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Paradyne BSX8000-5 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Paradyne BSX8000-5 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Paradyne BSX8000-5 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Paradyne BSX8000-5. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Paradyne BSX8000-5 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.