Service Manual Order No. PHA T070510C3 Automatic Rice Cooker SR-GA421/SR-GA281/SR-GA721 EXPORT © 2007 Panasonic Home Appliance (Thailand) Co.,Ltd All rights reserved. Unauthorized copying and distrbution is a violation of law . Specification Specification subject to change without notice.
2 SR-GA421/SR-GA281/SR-GA721 W ARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
3 SR-GA421/SR-GA281/SR-GA721 L N MICA HEA TER ASS’Y CAST HEA TER LAMP RESIST . T .F . INPUT SWITCH LAMP RESIST . KEEP WARM NEON LAMP (BIG) (SMALL ) E Green RICE COOKING NEON LAMP Lamp Lead Wire A (O.
4 SR-GA421/SR-GA281/SR-GA721 Cord Wire Earth (Green) Cord Wire Blue (N) Cord Wire Brown (L) Heater lead wire B (grey) Thermal fuse lead wire (Blue) Thermal fuse lead wire (Grey ) User positio n Heater.
5 SR-GA421/SR-GA281/SR-GA721 2. FUNCTION OF CENTER THERMOST A T AND THERMALFUSE A. Center Thermostat The center thermostat senses when the bottom of the rice cooker pan reach 134°C ± 6°C. And it’s action turns of f the cooking cycle, and starts the warming cycle.
6 SR-GA421/SR-GA281/SR-GA721 C. Thermal Fuse The thermal fuse is used to open the circuit to the cooking heater when the temperature has gone unusually high. This happens in cases such as incomplete contact between the heater and pan or if the switch buttons is forced to stay on keeping the heater energized abnormally .
7 SR-GA421/SR-GA281/SR-GA721 3. TROUBLESHOOTING GUIDE Symptom Diagnosis Remedy Cooking function ● Cooking fails (Cooking lamp is not shown) No continuity of cord? Y es ● Replace AC cord. No continuity of thermal fuse? Y es ● Locate cause for fusing and replace fuse.
8 SR-GA421/SR-GA281/SR-GA721 3. TROUBLESHOOTING GUIDE Symptom Diagnosis Remedy ● Earlier Switching-off ● Poor cooking finish T oo hard T oo soft Half-boiled Poor contact between pan and sheathed heater? (Check with bubbling test) Y es ● Replace pan or sheathed heater .
9 SR-GA421/SR-GA281/SR-GA721 4. TESTING PROCEDURE 1. Bubbling test Input the pan in the main body , and lightly rotate the pan clockwise and counter clockwise to set the pan on the heating plate properly . 1. Fill water until the center area of the pan bottom is dipped, and close the lid.
10 SR-GA421/SR-GA281/SR-GA721 4. TESTING PROCEDURE 3. Boiling control lever adjustment Such a mechanical operation as center thermostat goes up and down is used to turn on and off the micro-switch. Check and adjust this relationship as shown below . When the boiling switch is turned on.
1 1 SR-GA421/SR-GA281/SR-GA721 5. EXPLODED VIEW & P ACKING VIEW (SR-GA421/SR-GA281) EXPLODED VIEW (SR-GA421/SR-GA281).
12 SR-GA421/SR-GA281/SR-GA721 5. EXPLODED VIEW & P ACKING VIEW (SR-GA421/SR-GA281) P ACKING VIEW (SR-GA421/SR-GA281).
13 SR-GA421/SR-GA281/SR-GA721 6. REPLACEMENT OF P ARTS LIST & P ACKING LIST (SR-GA421/SR-GA281) P ARTS LIST Ref. No. Part Name Part No. SR-GA421 SR-GA281 Silver White White White White Silver HK S.
14 SR-GA421/SR-GA281/SR-GA721 6. REPLACEMENT OF P ARTS LIST & P ACKING LIST (SR-GA421/SR-GA281) LIST OF SCREW Ref. No. Part Name Part No. SR-GA421 SR-GA281 Silver White White White White Silver HK.
15 SR-GA421/SR-GA281/SR-GA721 7. EXPLODED VIEW & P ACKING VIEW (SR-GA721) EXPLODED VIEW (SR-GA721) SR-GA721 / U.S..
16 SR-GA421/SR-GA281/SR-GA721 7. EXPLODED VIEW & P ACKING VIEW (SR-GA721) P ACKING VIEW (SR-GA721).
17 SR-GA421/SR-GA281/SR-GA721 8. REPLACEMENT OF P ARTS LIST & P ACKING LIST (SR-GA721) P ART LIST Ref. No. Part Name Part No. SR-GA721 White White White Silver MAL SIN-DBD SIN-RBD USA 1 LID ASS’.
18 SR-GA421/SR-GA281/SR-GA721 8. REPLACEMENT OF P ARTS LIST & P ACKING LIST (SR-GA721) LIST OF SCREW Ref. No. Part Name Part No. SR-GA721 White White White Silver MAL SIN-DBD SIN-RBD USA A T APPING SCREW XTN4+10BVW 2 2 2 2 B P .
Ein wichtiger Punkt beim Kauf des Geräts Panasonic SR-GA281 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Panasonic SR-GA281 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Panasonic SR-GA281 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Panasonic SR-GA281 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Panasonic SR-GA281 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Panasonic SR-GA281 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Panasonic SR-GA281 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Panasonic SR-GA281. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Panasonic SR-GA281 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.