Voltage Range 103 Volts to 127 Volts @ 60 Hz Application Low Back Pressure Compressor Cooling Static Cooling
Refrigerant Control . . Capillary Tube Evaporator
Temp. Range -31°F to 23°F / -35°C to -5°C

Capacity 290 Btu/h ±10% * E.E.R 3.29 Btu/Wh ±10% * Current 1.21 Amps *
Nominal Motor Data Motor Input 88 Watts* Rated Current . . . 1.22 Amps Type RSIR, PTC relay
Locked Rotor 7.13 Amps Start Current 13.00 Amps Coil Resistances Run 4.95 Ohms @ 68°F (20°C) Start . . . 9.05 Ohms
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
*Test Conditions for Performance Specifications
Test Oil Freol α 22 Shell Temp 170.0°F / 76.0°C Condensing Temp 130.0°F / 54.4°C Evaporating Temp -10.0°F / -23.3°C Ambient Temp 90.0°F / 32.2°C Gas Superheat 90.0°F / 32.2°C Liquid Sub-Cooling 90.0°F / 32.2°C
200 300 400 500 600 700 800 900 1,000 1,100 1,200 1,300
Overload Protector Nominal Operating Characteristics
-20 -10 0 10 20 30 40 Evaporating Temperature (°F)
Model Name T135AH3.1 Manufacturer Matsushita Temperature To Open: 275°F ± 9°F / 135°C ± 5°C
Rated Performance Data · Electrical Accessories


19mm (.75") DIA 4 Holes 16mm (.63") DIA 4 Holes
Tubes Tube O.D. Wall Material Suction 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper Process 0.3125 in. / 7.94 mm 0.028 in. / 0.7 mm Copper Discharge 0.25 in. / 6.35 mm 0.028 in. / 0.7 mm Steel
mm inches A 168.6 6.64 B 60.8 2.39 C 107.8 4.24 D 69.1 2.72 E 60.3 2.37 F 139.3 5.48
U.L. File # SA 4615 C.S.A. File #’s LR - 36593
* All dimensions are for reference only
General Data Oil Charge . . 215 cc ± 5 cc / 13.1 cu.in. ± 0.3 cu.in.
Net Weight With Oil 14.5 lbs, 6.6 kg Approved Oils FREOL α 22, FREOL α 22E Residual Moisture 120 mg max. Impurities 7 mg max. Displacement 3.56 cc. / 0.217 cu. in.
This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. This document is for reference only. For specifications, please contact Panasonic’s engineering department.

Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.