DE
Panasonic logo
Offizielle Bedienungsanleitung

Panasonic DA86C15RCU6

2 Seiten·64 KB·Kompressor·PDF·EN
Panasonic DA86C15RCU6
Inhaltsverzeichnis 2 Abschnitte MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz · 110°F 120°F 130°F AnzeigenAusblenden
Page 1 of the Panasonic DA86C15RCU6 user manual — 110°F 120°F 130°F
Seite 1 · Zum Vergrößern klicken
Seite 1
Panasonic DA86C15RCU6 — MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz diagram (page 1)
Abb. 1 · MATSUSHITA Compressor Single Phase 115 V MODEL# DA86…

MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz

Voltage Range 103 Volts to 127 Volts @ 60 Hz Application Low Back Pressure Compressor Cooling Static / Fan Cooling

Refrigerant Control . . Capillary Tube Evaporator

Temp. Range -31°F to 23°F / -35°C to -5°C

Cond. Temp I* Cond. Temp II* Capacity 1,031 Btu/h ±7% 1,140 Btu/h ±7% E.E.R 5.31 Btu/Wh ±7% 6.20 Btu/Wh ±7% Current 1.76 Amps 1.67 Amps

Nominal Motor Data Motor Input 194 Watts 184 Watts Rated Current 1.92 Amps Type RSCR, PTC relay

-40 -30 -20 -10 0 10 20

Locked Rotor 16.1 Amps Start Current 23.1 Amps Coil Resistances Run 2.51 Ohms @ 68°F (20°C) Start . . . 5.46 Ohms

*Test Conditions for Performance Specifications

Test Oil ISO VG 10 Shell Temp 170.0°F / 76.0°C Condensing Temp (I) 130.0°F / 54.4°C

-40 -30 -20 -10 0 10 20

(II) 105.0°F / 40.6°C Evaporating Temp -10.0°F / -23.3°C Ambient Temp 90.0°F / 32.2°C Gas Superheat 90.0°F / 32.2°C Liquid Sub-Cooling 90.0°F / 32.2°C

Overload Protector Nominal Operating Characteristics

-40 -30 -20 -10 0 10 20 Evaporating Temperature (°F)

110°F 120°F 130°F

Temperature To Open: 248 °F ± 9°F / 120°C ± 5°C Close: 142°F ± 20°F / 61°C ± 11°C Trip Current @158°F (70°C) 4.1 Amps ± 7.5% @77°F (25°C) 12.0 Amps @ 18 sec. max. P.T.C. Starting Device Nominal Operating Characteristics Model Name PTH490D-AS6R8 Manufacturer Murata Mfg Base resistance @ 77°F(25°C) ±20% 6.8 Ohms Power Consumption (max) 3.5 Watts Operation time 1.0 to 2.7 seconds Recovery time (max) 65 seconds Run Capacitor 15 µF 180 V (min.) †Although these accessories are listed by UL/CSA for use with this compressor, Matsushita assumes no responsibility whatsoever for these or any other components sourced by the refrigeration system manufacturer from third parties.9 – Point Data Evaporating Temp. Condensing Temp. Rating -30°F -10°F +10°F 130°FBtu/h Watts Amps E.E.R.500 122 1.45 4.091,031 194 1.76 5.311,864 283 2.21 6.58 120°FBtu/h Watts Amps E.E.R.542 124 1.46 4.361,080 191 1.75 5.661,923 273 2.16 7.04 110°FBtu/h Watts Amps E.E.R.583 125 1.46 4.661,135 188 1.73 6.041,958 261 2.10 7.51 Panasonic® Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9
Show 12 more labels / short text on this page
Rated Performance Data · Performance Curves · Input Power (W) · Current (A) · 2,500 · 2,250 · 1,750 2,000 · Capacity (BTU/H) · 1,500 · 1,000 1,250 · 500 750 · Electrical Accessories†
Page 2 of the Panasonic DA86C15RCU6 user manual — MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz
Seite 2 · Zum Vergrößern klicken
Seite 2
Panasonic DA86C15RCU6 — MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz diagram (page 2)
Abb. 2 · MATSUSHITA Compressor Single Phase 115 V MODEL# DA86…

MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz

Tubes Tube O.D. Wall Material Suction 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper Process 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper Discharge 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper

mm inches A 220.8 8.69 B 93.2 3.67 C 127.6 5.02 D 83.9 3.30 E 70.4 2.77 F 75.2 2.96

U.L. File # SA 4615 C.S.A. File #’s LR - 36593

* All dimensions are for reference only

General Data Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.

Net Weight With Oil 23.1 lbs, 10.5 kg Approved Oils:

This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. This document is for reference only. For specifications, please contact Panasonic’s engineering department.

FREOL . . α 10, α 10E, α 15, α 15E, α 22, α 22E ICI RL10H, RL15H, RL22H HENKEL ProEco 10S,15S, 22S Residual Moisture 120 mg max. Impurities 10 mg max. Displacement 8.56 cc. / 0.522 cu. in.

Panasonic DA86C15RCU6 — MATSUSHITA Compressor Single Phase 115 V MODEL# DA86C15RCU6 R-134a 60 Hz diagram (page 2)
Abb. 3 · MATSUSHITA Compressor Single Phase 115 V MODEL# DA86…

Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9

Frage zu Panasonic DA86C15RCU6 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Panasonic DA86C15RCU6

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Panasonic DA86C15RCU6 PDF-Anleitung

2 Seiten·64 KB·Kompressor·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…